ABSTRACT
Describes several techniques developed to increase the precision of Michelson interferometers in measuring electron cyclotron emission from tokamak plasmas. Description of the fast-scanning Michelson interferometer; Transmission line; Calibration; Data processing.
ACCESSION #
630756

 

Related Articles

  • New ECE diagnostics for the TEXTOR-94 tokamak. Udintsev, V. S.; van de Pol, M. J.; Donné, A. J. H.; Oosterbeek, J. W.; Kra¨mer-Flecken, A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p359 

    To aid the scientific research program on the Toroidal Experiment for Technology Oriented Research (TEXTOR)-94 tokamak, the existing electron cyclotron emission (ECE) diagnostics for the electron temperature studies are being extended with new systems that feature a good temporal and radial...

  • Electron Bernstein wave electron temperature profile diagnostic (invited). Taylor, G.; Efthimion, P.; Jones, B.; Munsat, T.; Spaleta, J.; Hosea, J.; Kaita, R.; Majeski, R.; Menard, J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p285 

    Electron cyclotron emission (ECE) has been employed as a standard electron temperature profile diagnostic on many tokamaks and stellarators, but most magnetically confined plasma devices cannot take advantage of standard ECE diagnostics to measure temperature. They are either...

  • Frequency and angular distribution of electron cyclotron emission at high temperatures (100–500 keV). Bornatici, M.; Ruffina, U.; Spada, M. // Physics of Fluids B: Plasma Physics;May90, Vol. 2 Issue 5, p874 

    The distribution of the electron cyclotron emission with respect to both the frequency and the viewing angle is analyzed for a loss-cone as well as an anti-loss-cone electron distribution function at temperatures between 100 and 500 keV. The accuracy of two approximate formulas for the...

  • Vertical-viewing electron cyclotron emission diagnostic for the DIII-D tokamak. James, Reed; Janz, S.; Ellis, R.; Boyd, D.; Lohr, John // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1611 

    The vertical-viewing electron cyclotron emission diagnostic on DIII-D will be used to assess the nonthermal electron distributions resulting from electron cyclotron heating and electron cyclotron current drive experiments. Electron cyclotron emission along a vertical chord is collected using an...

  • Electron cyclotron-electron Bernstein wave emission diagnostics for the COMPASS tokamak. Zajac, J.; Preinhaelter, J.; Urban, J.; Zacek, F.; Sestak, D.; Nanobashvili, S. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D911 

    The COMPASS tokamak recently started operation at the Institute of Plasma Physics AS CR, v.v.i., Prague. A new 16-channel radiometer, operating alternatively in three frequency bands, has been designed and constructed. The system is prepared for detection of normal electron cyclotron emission...

  • A Fourier transform spectrometer with fast scanning capability for tokamak plasma diagnostic. Buratti, P.; Zerbini, M. // Review of Scientific Instruments;Aug1995, Vol. 66 Issue 8, p4208 

    Describes the measurement of an electron cyclotron emission spectra in the FTU tokamak plasma diagnostics by means of a fast scanning Fourier transform spectrometer. Key element of the instrument; Linear variation of the path difference; Calibration of the spectrometer; Measurement of...

  • Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data. Tobias, B.; Domier, C. W.; Liang, T.; Kong, X.; Yu, L.; Yun, G. S.; Park, H. K.; Classen, I. G. J; Boom, J. E.; Donné, A. J. H.; Munsat, T.; Nazikian, R.; Van Zeeland, M.; Boivin, R. L.; Luhmann, N. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D928 

    A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of Te fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of...

  • A fast multichannel Martin-Puplett interferometer for electron cyclotron emission measurements on JET. Simonetto, A.; Sozzi, C.; Garavaglia, S.; Fessey, J. A.; Nowak, S.; JET-EFDA Contributors // Review of Scientific Instruments;Nov2011, Vol. 82 Issue 11, p113506 

    A Martin Puplett interferometer for electron cyclotron emission (ECE) measurements from JET tokamak plasmas was extended to multichannel operation for simultaneous radial and oblique ECE measurements. This paper describes the new optics and the instrument's performance.

  • ECE imaging of electron temperature and electron temperature fluctuations (invited). Deng, B. H.; Domier, C. W.; Luhmann, N. C.; Brower, D. L.; Cima, G.; Donné, A. J. H.; Oyevaar, T.; van de Pol, M. J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p301 

    Electron cyclotron emission imaging (ECE imaging or ECEI) is a novel plasma diagnostic technique for the study of electron temperature profiles and fluctuations in magnetic fusion plasma devices. Instead of a single receiver located in the tokamak midplane as in conventional ECE radiometers,...

Share