TITLE

Refiectometry on ITER and ITER Joint Central Team and Home Teams

AUTHOR(S)
Vayakis, G.; Bretz, N.; Doyle, E.; Vershkov, V. A.; Donne, A. J. H.; Irby, J.; Mase, A.; Sanchez, J.; Shevchenko, V. F.; Walker, C. I.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p435
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Focuses on the use of reflectometry on the International Thermonuclear Experimental Reactor to measure the density profile in the main plasma and the divertor and to provide measurements of the plasma position and shape supplementary to the magnetic diagnostics. Systems required to access the full plasma profile; Measurements of the scrape-off layer; Real-time calibration technique of the whole transmission line.
ACCESSION #
630741

 

Related Articles

  • X-mode heterodyne reflectometer for edge density profile measurements on Tore Supra. Clairet, F.; Sabot, R.; Bottereau, Ch.; Chareau, J. M.; Paume, M.; Heuraux, S.; Colin, M.; Hacquin, S.; Leclert, G. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p340 

    A new broadband reflectometer operating in the frequency range 50–75 GHz in extraordinary mode polarization has been developed and tested on Tore Supra to measure edge density profiles. Using solid state source and active frequency multipliers, it performs routine measurements in 20...

  • Microwave reflectometry for turbulence studies on ASDEX upgrade (abstract). Ribeiro, T. T.; Serra, F.; Manso, M. E.; Vergamota, S.; Cupido, L.; Silva, A.; Conway, G. D.; Ryter, F.; Suttrop, W. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p319 

    The reflectometry system installed in the tokamak ASDEX Upgrade has 11 channels primarily aimed at profile measurements and two dedicated channels operating at fixed frequency to study density fluctuations. The channels used for profile measurements can also be operated at fixed frequency. In...

  • The ten-channel pulsed radar reflectometer at the TEXTOR-94 tokamak. van Gorkom, J. C.; van de Pol, M. J.; Donné, A. J. H. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p336 

    A new ten-channel pulsed radar reflectometer has been taken into operation at the Torus Experiment for Technology Oriented Research-94. The system will be used simultaneously as a density profile and as a density fluctuation diagnostic. Ten density layers from 0.4×10[sup 19] to 4×10[sup...

  • Plasma mass density, species mix, and fluctuation diagnostics using a fast Alfven wave. Ikezi, H; deGrassie, J S; Pinsker, R I; Snider, R T // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p478 

    Proposes the use of a fast Alfven wave interferometer and reflectometer as a tokamak diagnostic to measure the plasma mass density, deuterium-tritium species mix profile, and density fluctuations. Phase velocity of the fast wave propagating across the magnetic field; Position of the ion-ion...

  • Simulation of reflectometry density changes using a 2D full-wave code. da Silva, F.; Manso, M.; Silva, A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p311 

    Broadband reflectometry is used to obtain density profiles in fusion plasmas using waves reflected at different plasma layers. The reflected signal can be severely affected by plasma fluctuations and/or fast density changes. In order to understand the plasma response, a finite difference time...

  • Asymmetric double Langmuir probe: Small signal application. Uckan, Taner // Review of Scientific Instruments;Dec1987, Vol. 58 Issue 12, p2260 

    We discuss the asymmetric double Langmuir probe (ADLP) and demonstrate the possibility of using it to measure plasma temperature Te and density n when it is operated in the region of small signal response. The area of one of the ADLP collectors is considerably larger than the other. This probe...

  • High resolution measurements of neutral density and ionization rate in the Alcator C-Mod tokamak. Boivin, R. L.; Hughes, J. W.; LaBombard, B.; Mossessian, D.; Terry, J. L. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p961 

    Two new high resolution detectors have been installed on the Alcator C-Mod tokamak to measure the neutral density and ionization rate at the edge of the main chamber plasma. Using a silicon detector sensitive to UV light, and a very narrow filter with transmission peaking at 1216 Ã…, the...

  • Doppler reflectometry for the investigation of propagating density perturbations. Hirsch, M.; Holzhauer, E.; Baldzuhn, J.; Kurzan, B. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p324 

    In a Doppler reflectometry experiment the line of sight is chosen to be nonperpendicular with respect to the reflecting layer. This type of diagnostic is able to probe density perturbations with the wave number in the reflecting layer selected by the tilt angle. The propagation velocity of the...

  • Performance of the microwave reflectometry diagnostic for density profile measurements on ASDEX Upgrade. Silva, A.; Manso, M.; Vergamota, S.; Cupido, L.; Meneses, L.; Nunes, I. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p307 

    The broadband reflectometry system on ASDEX Upgrade is now routinely providing electron density profiles with a minimum temporal spacing of 30 μs. The plasma is probed from zero density to n[sub e]=6.64×10[sup 19] m[sup -3] at the low field side with combined O and X modes, and from n[sub...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.