TITLE

Multichannel far-infrared polarimeter system on TEXT-Upgrade

AUTHOR(S)
Brower, D. L.; Zeng, L.; Jiang, Y.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p419
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the addition of a far-infrared polarimeter diagnostic to the University of California at Los Angeles multichord heterodyne interferometer system on the TEXT-Upgrade tokamak. Design of the polarimeter/interferometer system; Equilibrium profiles; Tearing modes; Fast current ramps and current diffusion.
ACCESSION #
630735

 

Related Articles

  • Two-wavelength infrared interferometer/polarimeter system for CIT. Ma, C. H.; Hutchinson, D. P.; Vander Sluis, K. L. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1629 

    The results of a feasibility study of a two-wavelength infrared interferometer/polarimeter system for measurements of electron density and plasma current profiles in the Compact Ignition Tokamak (CIT) are presented. The system utilizes CO[sub 2] lasers at a wavelength of 10.6 µm, and...

  • Multichannel submillimeter interferometer/polarimeter for TdeV. Lachambre, J.-L.; Gagné, M. // Review of Scientific Instruments;Nov94, Vol. 65 Issue 11, p3428 

    An interferometer/polarimeter has been developed and tested for operation on the TdeV tokamak. The system operates at 393.6 µm on 7 channels equally spaced over the plasma diameter. The interferometer has operated routinely for six years and is used for density feedback control on TdeV, with...

  • Multichannel interferometer/polarimeter system for the RTP tokamak. van Lammeren, A. C. A. P.; Kim, S. K.; Donné, A. J. H. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2882 

    A nine-channel interferometer/polarimeter system is designed for the RTP tokamak (Rijnhuizen Tokamak Project, a = 0.16 m, R = 0.72 m, B[sub T] = 2.5 T, I[sub p] ≤ 200 kA, and plasma pulse duration 200 ms). A CO[sub 2]-pumped dual-cavity FIR laser system is used to obtain two FIR laser...

  • Fast heterodyne interferometer with electronically stabilized initial phase. van der Geer, C. A. J.; van der Meer, A. F. G.; Mastop, W. J. // Review of Scientific Instruments;Dec1985, Vol. 56 Issue 12, p2263 

    A heterodyne interferometer setup with initial-phase stabilization is described, which allows the full range of ‘‘half a fringe’’ to be used without ambiguity, using only one phase comparator. This phase stabilization is achieved by the insertion of a voltage-controlled...

  • The multichannel triple-laser interferometer/polarimeter system at RTP (abstract) Rommers, J. H.; Donne, A. J. H.; Karelse, F. A.; Howard, J. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p446 

    Describes a 19-channel combined interferometer and polarimeter system at the Rijnhuizen Tokamak Project in the Netherlands that is being used to determine the poloidal magnetic field and plasma density distribution simultaneously. Theoretical basis for the method.

  • Two-frequency displacement measurement interferometer based on a double-heterodyne technique. Chien, Pie-Yau // Review of Scientific Instruments;Jan1991, Vol. 62 Issue 1, p254 

    A two-frequency laser heterodyne interferometer has been implemented for small displacement measurement. The displacement signal is detected by using a double-heterodyne technique. Vibration amplitudes at 1 kHz on the order of 1 nm and smaller can be detected.

  • Influence of refraction on plasma density measurements. Petrov, V. G. // Plasma Physics Reports;Apr2006, Vol. 32 Issue 4, p311 

    The plasma density profile in the T-11M tokamak is measured with a multichannel Cotton-Mouton polarimeter and also with a time-of-flight refractometer. Both instruments operate at frequencies in the range of 140 GHz. Since, in this case, the trajectory of the probing microwave beam deviates from...

  • 10-channel far-infrared polarimeter for the tokamak à configuration variable. Blanchard, P.; Behn, R.; Weisen, H.; Zhuchkova, A. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F101 

    A new far-infrared polarimeter diagnostic for the tokamak à configuration variable (TCV) is under construction at CRPP. It uses two FIR lasers at 432.5 μm, optically pumped by a 120 W continuous wave CO2 laser. The two FIR cavities will be detuned such that the combination of the beams,...

  • Density modulation experiment to determine transport coefficients on Joint-TEXT Tokamak. Chen, W.; Zhuang, G.; Gao, L.; Gentle, K. W.; Chen, J.; Shi, P.; Liu, Y.; Li, Q.; Wang, Z. J. // Review of Scientific Instruments;Feb2015, Vol. 86 Issue 2, p1 

    Density modulation experiments have been conducted on Joint-TEXT (J-TEXT) Tokamak Ohmic discharge to investigate particle transport based on a model with constant diffusion plus inward convection. Like the HCN interferometer, the newly developed three-wave polarimeter-interferometer system...