ABSTRACT
Describes a technique for identifying a parallel connection between Langmuir probes and other diagnostics on the TEXT-U tokamak. Method for the identification of a magnetic field line; Separation of the amplitude and phase of driven potential fluctuations at the sensor probes from background turbulent fluctuations; Evaluation of the safety factor in the edge plasma.
ACCESSION #
630728

 

Related Articles

  • The influence of magnetization strength on the sheath: Implications for flush-mounted probes. Gunn, J.P. // Physics of Plasmas;Dec97, Vol. 4 Issue 12, p4435 

    Evaluates whether or not flush-mounted probes (FMP) can be used routinely as plasma diagnostic tools, not only in tokamaks but also in any situation where strong, obliquely inclined magnetic fields are present. Use of one-dimensional particle-in-cell simulations; Behavior of ion current...

  • Preliminary design of a heavy ion beam probe diagnostic for the National Spherical Torus Experiment. Mull, F.H.; Crowley, T.P.; Schoch, P.M.; Connor, K.A. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p959 

    Presents the preliminary design of a heavy ion beam probe (HIBP) for the National Spherical Torus Experiment. Primary purpose of the diagnostic probe; Principle of heavy ion beam probing; Beam attenuation and signal levels; Potential, density and particle flux measurements; Magnetic vector...

  • A heavy ion beam probe for the Madison Symmetric Torus. Shah, U.; Connor, K.A.; Lei, J.; Schoch, P.M.; Crowley, T.P.; Schatz, J.G.; Dong, Y. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p963 

    Describes the development of a heavy ion beam probe for application on the Madison Symmetric Torus tokamak. Measurement of the plasma space potential, fluctuations in potential, electron density, fluctuating electron density and radial electric field; Design of the probe system; Reliability.

  • Recent results from tokamak divertor plasma measurements (invited) (abstract) Allen, S. L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p886 

    Presents an abstract of a paper discussing the development of plasma diagnostics to address key tokamak divertor physics questions. Plasma measurements; Plasma probes; Spectroscopic measurements; Measurement of fundamental plasma transport and fluctuations.

  • Electrical probe with guard and automatic positioner. García-Hernández, J. M.; López-Callejas, R.; Camps-Carvajal, E.; Benítez-Read, J. S. // Review of Scientific Instruments;Apr2000, Vol. 71 Issue 4 

    We present the design and construction of a diagnostic system of the plasma parameters by means of electrical probes. The novelties of the system are the protection provided to the electrical probe with a guard, thus minimizing the probe deterioration, and the automatic positioning device...

  • Plasma measurements with triple and single probes in an asymmetrical parallel plate rf plasma reactor Murata, Kinji; Kubo, Takashi; Kiwata, Hiroaki // Review of Scientific Instruments;Jul98, Vol. 69 Issue 7, p2681 

    Performs plasma measurements with triple and single probes in an asymmetrical parallel plate rf plasma reactor. Agreement on two probe characteristics with the single and triple probes; Connection of the compensation circuits to the probe system; Reason why the measurement results suffer from...

  • Point-to-point analysis of MSE data for plasma diagnostics and control. Giannella, R.; Hawkes, N. C.; Jayakumar, R.; Makowski, M.; Zabeo, L. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4247 

    A local analysis technique is presented for the analysis of MSE data to deduce the safety factor q in tokamak discharges. The technique preserves as much as possible the individuality of every single measure by a simple rule of translation of magnetic field pitch angle measurements into...

  • Langmuir probe technique for plasma parameter measurement in a medium density discharge. Hopkins, M. B.; Graham, W. G. // Review of Scientific Instruments;Sep86, Vol. 57 Issue 9, p2210 

    The development of a microcomputer-controlled electrostatic probe as a diagnostic technique is described. The technique uses cylindrical probes and the definitive theory of Laframboise to give rapid measurements of the plasma parameters in a medium density (1010 to 1012 cm-3) plasma including...

  • Janus, a bidirectional, multifunctional plasma diagnostic. Wan, A. S.; Yang, T. F.; Lipschultz, B.; LaBombard, B. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1542 

    Janus is a multiple-function edge probe used to diagnose the Alcator C limiter shadow plasma whose components include two sets of identical diagnostics, each set facing a different direction. Included within each set of diagnostics are a retarding-field energy analyzer (RFEA), Langmuir probe,...