TITLE

Equilibrium reconstructions of reversed-shear discharges based on motional Stark effect measurements

AUTHOR(S)
Batha, S. H.; Levinton, F. M.; Wieland, R. M.; Hirshman, S. P.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p392
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Details how free-boundary equilibrium reconstructions of the temporal evolution of tokamak discharges can be made using internal magnetic field measurements taken in tokamak discharges with a motional Stark effect polarimeter. Boundary positioning algorithm; Variable tension splines; Uncertainty of the q profile in reverse shear discharges.
ACCESSION #
630727

 

Related Articles

  • Polarimetry of motional Stark effect and determination of current profiles in DIII-D (invited). Wróblewski, D.; Lao, L. L. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5140 

    The motional electric field E=v × B, where v is the velocity and B is the tokamak magnetic field, produces a strong Stark effect in spectral lines emitted by hydrogenic neutral beams. The tilt angle of the magnetic field line, a quantity related directly to the distribution of the plasma...

  • The motional Stark effect diagnostic on TEXTOR-94: First measurements. Soetens, T.; Jaspers, R.; Desoppere, E. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p890 

    Describes the development of a diagnostic to measure the motional Stark effect (MSE) on TEXTOR-94 limiter tokamak. Source of the motional Stark effect; Components of the MSE diagnostic; Proportionality of the toroidal magnetic field to the major radius of the observation volume.

  • Magnetohydrodynamic interference with the edge pedestal motional Stark effect diagnostic on DIII-D. King, J. D.; Makowski, M. A.; Holcomb, C. T.; Allen, S. L.; Hill, D. N.; La Haye, R. J.; Turco, F.; Petty, C. C.; Van Zeeland, M. A.; Rhodes, T. L.; Meyer, W. H.; Geer, R.; Morse, E. C. // Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033515 

    Accurate measurement of internal magnetic field direction using motional Stark effect (MSE) polarimetry in the edge pedestal is desired for nearly all tokamak scenario work. A newly installed 500 kHz 32-channel digitizer on the MSE diagnostic of DIII-D allows full spectral information of the...

  • Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited). Pablant, N. A.; Burrell, K. H.; Groebner, R. J.; Holcomb, C. T.; Kaplan, D. H. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D729 

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line...

  • Available information in 2D motional Stark effect imaging. Creese, Mathew; Howard, John // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D722 

    Recent advances in imaging techniques have allowed the extension of the standard polarimetric 1D motional Stark effect (MSE) diagnostic to 2D imaging of the internal magnetic field of fusion devices [J. Howard, Plasma Phys. Controlled Fusion 50, 125003 (2008)]. This development is met with the...

  • Ab initio modeling of the motional Stark effect on MAST. De Bock, M. F. M.; Conway, N. J.; Walsh, M. J.; Carolan, P. G.; Hawkes, N. C. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F524 

    A multichord motional Stark effect (MSE) system has recently been built on the MAST tokamak. In MAST the π and σ lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch...

  • Measurements of the internal magnetic field on DIII-D using intensity and spacing of the motional Stark multiplet. Pablant, N. A.; Burrell, K. H.; Groebner, R. J.; Kaplan, D. H.; Holcomb, C. T. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F517 

    We describe a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of Stark split Dα emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the...

  • Transport with reversed shear in the National Spherical Torus Experiment. Levinton, F. M.; Yuh, H.; Bell, M. G.; Bell, R. E.; Delgado-Aparicio, L.; Finkenthal, M.; Fredrickson, E. D.; Gates, D. A.; Kaye, S. M.; LeBlanc, B. P.; Maingi, R.; Menard, J. E.; Mikkelsen, D.; Mueller, D.; Raman, R.; Rewoldt, G.; Sabbagh, S. A.; Stutman, D.; Tritz, K.; Wang, W. // Physics of Plasmas;May2007, Vol. 14 Issue 5, p056119 

    In the National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 (2000)], plasmas with strongly reversed magnetic shear, s≡(r/q)(dq/dr)<0, in the plasma core exhibit a marked improvement in electron confinement compared to otherwise similar plasmas with positive or...

  • Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T. Lizunov, A.; Donin, A.; Savkin, V. // Review of Scientific Instruments;Aug2013, Vol. 84 Issue 8, p086104 

    The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics