TITLE

A study for the installation of the TEXT heavy-ion beam probe on DIII-D

AUTHOR(S)
Edmonds, P. H.; Solano, E. R.; Bravenec, R. V.; Wootton, A. J.; Schoch, P.M.; Crowley, T. P.; Hickok, R. L.; West, W. P.; Leuer, J.; Anderson, P.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p320
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses the results of an assessment of the feasibility of installing the TEXT 2 MeV heavy-ion beam probe (HIBP) on the DIII-D tokamak. Background information on the HIBP diagnostic; Expected diagnostic performance; Design procedure; Key design issues.
ACCESSION #
630708

 

Related Articles

  • Heavy ion beam probe systems for tight aspect ratio toKamaKs Melnikov, A. V.; Zimeleva, L. G.; Krupnik, L. I.; Nedzelskij, I. S.; Trofimenko, Y. V.; Minaev, V. B. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p316 

    Discusses the specific features of the application of heavy ion beam probe systems to tight aspect ratio tokamaks. Brief description of the observed tokamaks from the viewpoint of the probing beam pass; Optimization procedure; Three-dimensional case.

  • Heavy ion beam probe diagnostics on TJ-1 tokamak and the measurements of the plasma potential and density profiles Bondarenko, I. S.; Khrebtov, S. M.; Krupnik, L. I.; Nedzelskij, I. S.; Gordeev, O. A.; Kharchev, N K.; Melnikov, A, V.; Tarasyan, K. N.; Zimeleva, L. G.; Hidalgo, C.; Garcia-Codes, I. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p312 

    Describes the application of the heavy ion beam probe (HIBP) diagnostics to the investigation of the plasma density and potential in the TJ-1 tokamak. Analyzer characteristics, calibration procedures and analysis of the plasma potential data; Plasma density.

  • Calibration of the heavy ion beam probe parallel plate analyzer using the gas target and reference beam Melnikov, A. V.; Kharchev, N. K.; Eliseev, L. G.; Bondarenko, I. S.; Krupnik, L. I.; Khrebtov, S. M.; Nedzelskij, I. S.; Trofimenko, Yu. V. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p308 

    Develops a procedure of fast calibration of the heavy ion beam probe parallel plate analyzer using the gas target and reference beam. Test facility in vitro calibration; Gas target in situ calibration; Nonideal effects in calibration.

  • Advances in heavy-ion beam probing. Connor, K. A.; Crowley, T. P.; Hickok, R. L.; Carnevali, A.; Schoch, P. M.; Resnick, J.; Simcic, V.; Schatz, J. G.; Heard, J.; Aceto, S. C.; Lewis, J. F. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1673 

    Recent applications of heavy-ion beam probes on such devices as the TEXT tokamak have shown the importance of increasing the capabilities of both the beam injection and detection systems. To this end we have investigated a new solid-state ion detector that will substantially improve spatial...

  • HIBP Diagnostics On T-10. Melnikov, A.V.; Bondarenko, I.S.; Efremov, S.L.; Kharchev, N.K.; Khrebotv, S.M.; Krupnik, L.I.; Nedzelskiji, I.S.; Zimeleva, L.G.; Trofimenko, Yu.V. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p317 

    Installs a heavy ion beam probe diagnostic (HIBP) on a T-10 tokamak. Ability of the diagnostic to make two-dimensional measurements of plasma parameters along the detector line; Detector grid covering the first quadrant of the plasma cross section.

  • Effect of the sample volume splitting in heavy ion-beam probing (HIBP) for spherical tokamaks (by the example of HIBP for mega ampere spherical tokamak) Melnikov, A.V.; Melnikov, A. V.; Perfilov, S.V.; Perfilov, S. V. // Review of Scientific Instruments;Feb1999, Vol. 70 Issue 2, p1402 

    Proposes the heavy ion-beam probing (HIBP) project for the mega ampere spherical tokamak to establish systematic research of the radial electric field as an idea to investigate both the reactor-related physics and basic plasma physics. HIBP optimization; Types of probing trajectories; Crossover...

  • Measurements of plasma fluctuations with a heavy-ion beam probe. Hallock, G. A.; Schoch, P. M.; Saadatmand, K.; Hickok, R. L.; Jennings, W. C.; Connor, K. A. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p1038 

    A heavy-ion beam probe can provide simultaneous, spatially resolved measurements of &φtilde;; and (ñσ[sub eff]) in magnetically confined plasmas. Capabilities have been demonstrated on TMX, RENTOR, and ISX-B using single detector systems, which permit the evaluation of the frequency...

  • Comparative study design of a heavy ion and neutral beam diagnostic for the International Tokamak Experiment Reactor. Malaquias, A.; Nedzelsky, I.; Gonçalves, B.; Varandas, C. A. F.; Cabral, J. A. C.; Melnikov, A.; Eliseev, L.; Perfilov, S.; Yudina, O.; Krupnik, L. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1857 

    In this article, we address the major physics principles and the engineering issues associated with the implementation of a heavy ion beam diagnostic for the International Tokamak Experiment Reactor (ITER) for the edge measurements of the plasma electric and poloidal magnetic fields. Two...

  • Operation of a multiple cell array detector in plasma experiments with a heavy ion beam diagnostic. Gonçalves, B.; Malaquias, A.; Nedzelskiy, I. S.; Pereira, L.; Silva, C.; Varandas, C. A. F.; Cabral, J. A. C.; Khrebtov, S. M.; Dreval, N. B.; Krupnik, L. I.; Hidalgo, C.; Depablos, J. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3511 

    A multiple cell array detector (MCAD) has been developed to investigate the spatial structure of plasma turbulence in fusion plasmas. This system is expected to provide simultaneous measurements of edge and core density fluctuations with both temporal and spatial resolution, extending the range...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics