TITLE

Heavy ion beam probe diagnostics on TJ-1 tokamak and the measurements of the plasma potential and density profiles

AUTHOR(S)
Bondarenko, I. S.; Khrebtov, S. M.; Krupnik, L. I.; Nedzelskij, I. S.; Gordeev, O. A.; Kharchev, N K.; Melnikov, A, V.; Tarasyan, K. N.; Zimeleva, L. G.; Hidalgo, C.; Garcia-Codes, I.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p312
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the application of the heavy ion beam probe (HIBP) diagnostics to the investigation of the plasma density and potential in the TJ-1 tokamak. Analyzer characteristics, calibration procedures and analysis of the plasma potential data; Plasma density.
ACCESSION #
630706

 

Related Articles

  • Heavy ion beam probe systems for tight aspect ratio toKamaKs Melnikov, A. V.; Zimeleva, L. G.; Krupnik, L. I.; Nedzelskij, I. S.; Trofimenko, Y. V.; Minaev, V. B. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p316 

    Discusses the specific features of the application of heavy ion beam probe systems to tight aspect ratio tokamaks. Brief description of the observed tokamaks from the viewpoint of the probing beam pass; Optimization procedure; Three-dimensional case.

  • A study for the installation of the TEXT heavy-ion beam probe on DIII-D Edmonds, P. H.; Solano, E. R.; Bravenec, R. V.; Wootton, A. J.; Schoch, P.M.; Crowley, T. P.; Hickok, R. L.; West, W. P.; Leuer, J.; Anderson, P. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p320 

    Discusses the results of an assessment of the feasibility of installing the TEXT 2 MeV heavy-ion beam probe (HIBP) on the DIII-D tokamak. Background information on the HIBP diagnostic; Expected diagnostic performance; Design procedure; Key design issues.

  • Calibration of the heavy ion beam probe parallel plate analyzer using the gas target and reference beam Melnikov, A. V.; Kharchev, N. K.; Eliseev, L. G.; Bondarenko, I. S.; Krupnik, L. I.; Khrebtov, S. M.; Nedzelskij, I. S.; Trofimenko, Yu. V. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p308 

    Develops a procedure of fast calibration of the heavy ion beam probe parallel plate analyzer using the gas target and reference beam. Test facility in vitro calibration; Gas target in situ calibration; Nonideal effects in calibration.

  • Observation of plasma density fluctuations by a heavy ion beam probe diagnostic with multiple cell array detector on the tokamak ISTTOK. Nedzelskiy, I. S.; Coelho, R.; Alves, D.; Silva, C.; Fernandes, H. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F319 

    The heavy ion beam probe (HIBP) diagnostic permits the measurements of electron density and plasma potential as well as their fluctuations. The use of a multiple cell array detector (MCAD) spreads the HIBP capabilities to make simultaneous measurements across the plasma column. Two sets of...

  • New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic. Henriques, R. B.; Nedzelskiy, I. S.; Malaquias, A.; Fernandes, H. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10D705 

    The tokamak ISTTOK havy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma...

  • Advances in heavy-ion beam probing. Connor, K. A.; Crowley, T. P.; Hickok, R. L.; Carnevali, A.; Schoch, P. M.; Resnick, J.; Simcic, V.; Schatz, J. G.; Heard, J.; Aceto, S. C.; Lewis, J. F. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1673 

    Recent applications of heavy-ion beam probes on such devices as the TEXT tokamak have shown the importance of increasing the capabilities of both the beam injection and detection systems. To this end we have investigated a new solid-state ion detector that will substantially improve spatial...

  • HIBP Diagnostics On T-10. Melnikov, A.V.; Bondarenko, I.S.; Efremov, S.L.; Kharchev, N.K.; Khrebotv, S.M.; Krupnik, L.I.; Nedzelskiji, I.S.; Zimeleva, L.G.; Trofimenko, Yu.V. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p317 

    Installs a heavy ion beam probe diagnostic (HIBP) on a T-10 tokamak. Ability of the diagnostic to make two-dimensional measurements of plasma parameters along the detector line; Detector grid covering the first quadrant of the plasma cross section.

  • Effect of the sample volume splitting in heavy ion-beam probing (HIBP) for spherical tokamaks (by the example of HIBP for mega ampere spherical tokamak) Melnikov, A.V.; Melnikov, A. V.; Perfilov, S.V.; Perfilov, S. V. // Review of Scientific Instruments;Feb1999, Vol. 70 Issue 2, p1402 

    Proposes the heavy ion-beam probing (HIBP) project for the mega ampere spherical tokamak to establish systematic research of the radial electric field as an idea to investigate both the reactor-related physics and basic plasma physics. HIBP optimization; Types of probing trajectories; Crossover...

  • Measurements of plasma fluctuations with a heavy-ion beam probe. Hallock, G. A.; Schoch, P. M.; Saadatmand, K.; Hickok, R. L.; Jennings, W. C.; Connor, K. A. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p1038 

    A heavy-ion beam probe can provide simultaneous, spatially resolved measurements of &φtilde;; and (ñσ[sub eff]) in magnetically confined plasmas. Capabilities have been demonstrated on TMX, RENTOR, and ISX-B using single detector systems, which permit the evaluation of the frequency...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics