TITLE

Improved energy resolution for scintillator based gamma-ray detectors obtained using a CsI(TI)/Si-PIN detector

AUTHOR(S)
Iwanczyk, J.S.; Patt, B.E.
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3926
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reports on improved energy resolution measured using a gamma-ray detector consisting of a CsI(Tl) scintillator coupled to a photodiode (PD). Measurements made in an evacuated chamber; Performance of charge calibration by measuring the direct PD response.
ACCESSION #
627550

 

Related Articles

  • Submillimeter resolution in one-dimensional position measurements of γ-ray photons by using a CsI(Tl) scintillator coupled to a linear array of silicon drift detectors. Fiorini, C.; Labanti, C.; Perotti, F. // Review of Scientific Instruments;Aug2000, Vol. 71 Issue 8 

    We present the one-dimensional (1D) position and energy resolution results obtained by a γ-ray detector based on a single CsI(Tl) scintillator coupled to a linear array of silicon drift detectors (SDDs). The present prototype has been realized in order to investigate the basic performances of...

  • The use of energy information in plastic scintillator material. Ely, J.; Anderson, K.; Bates, D.; Kouzes, R.; Lo Presti, C.; Runkle, R.; Siciliano, E.; Weier, D. // Journal of Radioanalytical & Nuclear Chemistry;Jun2008, Vol. 276 Issue 3, p743 

    Plastic scintillator material is often used for gamma-ray detection in many applications due to its relatively good sensitivity and cost-effectiveness compared to other detection materials. However, due to the dominant Compton scattering interaction mechanism, full energy peaks are not observed...

  • INITIAL RESULTS FOR THE DEVELOPMENT OF A SMALL FIELD OF VIEW GAMMA-RAY IMAGER USING A LuAG:Pr SCINTILLATOR. Stratos, David; Maria, Georgiou; Eleftherios, Fysikopoulos; Loudos, George // e-Journal of Science & Technology;2012, Vol. 7 Issue 3, p15 

    In this study we present the initial results for the construction and the evaluation of a small field of view gamma ray detector based on a R8900U-00-C12 position sensitive photomultiplier tube (PSPMT) coupled to a 2x2 LuAG:Pr scintillator array with 5x5x5mm³ crystal size elements. We have...

  • MIT fusion γ-ray diagnostic development. Wenzel, K. W.; Petrasso, R. D.; Lo, D. H.; Li, C. K.; Coleman, J. W.; Lierzer, J. R.; Hsieh, E.; Bernat, T. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4840 

    In conjunction with γ-ray diagnostic development for the NOVA Upgrade and Alcator C-MOD experiments, we have assembled a comprehensive set of absolutely calibrated γ-ray sources and several γ-ray detectors. These tools will be used in characterizing and calibrating new γ-ray...

  • Germanium gamma-ray detectors. Pehl, Richard H. // Physics Today;Nov77, Vol. 30 Issue 11, p50 

    Explores the characteristics of Germanium-based gamma-ray detectors. Description of detectors; Charge production and collection; Process involved in activation analysis.

  • High energy gamma-rays expected from microquasars. Atoyan, Armen; Aharonian, Felix // AIP Conference Proceedings;2001, Vol. 558 Issue 1, p234 

    Based on the results of detailed modelling of the powerful radio flare of the microquasar GRS 1915+105 in March/April 1994, here we discuss γ-ray fluxes which can be expected from this class of objects. We discuss also perspectives and possible strategy for detection of microquasars in high...

  • Test campaign of the mini-calorimeter for the AGILE satellite. Auricchio, Natalia; Celesti, Enrico; Di Cocco, Guido; Galli, Marcello; Gianotti, Fulvio; Labanti, Claudio; Mauri, Alessandro; Malaspina, Marco; Rossi, Elio; Stephen, John B.; Traci, Alessandro; Trifoglio, Massimo // AIP Conference Proceedings;2001, Vol. 587 Issue 1, p749 

    The AGILE Mini-Calorimeter (MCAL, with total on-axis radiation length 1.5 X[SUBo]) comprises 2 orthogonal planes each consisting of 16 CsI(T1) bars. Its primary purpose is the energy determination of gamma-rays detected by the Gamma-Ray Imaging Detector (GRID) Tracker (energy range 30 MeV - 50...

  • Absolute calibration of fusion gamma ray detector on TFTR. Medley, S. S.; Roquemore, A. L.; Cecil, F. E. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4857 

    An in situ measurement of the absolute detection efficiency of the fusion gamma ray detector on TFTR has been completed. The efficiency was determined by measuring the yield of the 4.44 MeV gamma ray from a plutonium-berrylium source situated within the vacuum vessel. The absolute detection...

  • List-mode coincidence data analysis for highly selective and low background detection of gamma-nuclides in activated samples. Matsumura, H.; Masumoto, K.; Toyoda, A.; Kinoshita, N. // Journal of Radioanalytical & Nuclear Chemistry;Dec2008, Vol. 278 Issue 3, p733 

    Highly selective and sensitive γ-ray detection was performed by coincidence and anticoincidence event analysis after list-mode data acquisition using an HPGe spectrometer equipped with NaI(Tl) and plastic scintillation detectors. In order to obtain the most suitable detection of specific...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics