TITLE

A CdS photoconductivity gas sensor as an analytical tool for detection and analysis of hazardous gases in the environment

AUTHOR(S)
Miremadi, Bijan K.; Colbow, Konrad; Harima, Yutaka
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3898
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Develops a highly sensitive gas sensor for detection and analytical identification of hazardous gases, by depositing partially crystalline powder from an aqueous suspension of CdS powder on an alumina substrate. Sample preparation; Schematic diagram of the apparatus and measuring system; Measuring parameters.
ACCESSION #
627537

 

Related Articles

  • Microcantilever charged-particle flux detector. Stephan, A. C.; Gaulden, T.; Brown, A.-D.; Smith, M.; Miller, L. F.; Thundat, T. // Review of Scientific Instruments;Jan2002, Vol. 73 Issue 1, p36 

    A micromechanical sensor for charged-particle flux detection utilizing the extreme force sensitivity of microcantilevers is demonstrated with alpha particles. The latter create a charge buildup on an electrically isolated collection plate, a metallic sphere. The cantilever detector measures the...

  • Shape of β spectrum obtained with thin detectors. Ouseph, P. J.; Davis, C. L.; O’Bryan, M. Ray // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p962 

    The β spectrum of Tl obtained using a 200-μm detector is distorted with a prominent peak centered around 97 keV. The features of this spectrum can be reproduced by a Monte Carlo procedure. The minimum ionizing nature of the electrons with energy higher than about 300 keV is responsible for...

  • Calibration of a Mott detector using circularly polarized impact radiation from helium. Uhrig, M.; Beck, A.; Goeke, J.; Eschen, F.; Sohn, M.; Hanne, G. F.; Jost, K.; Kessler, J. // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p872 

    The conventional methods of determining the analyzing power of a Mott detector for electron-polarization measurement are not very accurate. That is why alternative methods have recently been discussed. The present paper shows how a Mott detector can be calibrated with an uncertainty of ±1%...

  • Continuous level sensors for cryogenic liquids using high-Tc superconductors. Siegmann, St.; Frey, T.; Ramseyer, J. P.; Güntherodt, H.-J. // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1946 

    We have developed a new device using high-temperature superconducting sensors for the continuous detection and control of the level of cryogenic liquids with boiling temperatures of up to 90 K. The sensors contain material of La-(Ba,Sr)-Cu or Y-Ba-Cu oxides with superconducting transition...

  • Charge-coupled device image detector for Schmidt telescopes. Natali, Giuliano; Pedichini, Fernando // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1839 

    The application of a charge-coupled device sensor at the focal plane of a Schmidt telescope is described. The device installed on the 60/90/180 cm Schmidt telescope at Campo Imperatore Astrophysical Observatory has a field of view of 17×25 arcmin. A special LN2 cooling system was installed...

  • A small electron cyclotron resonant plasma-based neutral-flux ionizer. Cain, B. L.; Ruzic, D. N. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3473 

    The design and operation of a neutral-hydrogen flux detection system is described. The central feature of the detector is an inductively driven electron cyclotron resonance heated (ECRH) discharge, which functions as the neutral-flux ionizer. The prominent features of the ionizer are its small...

  • Determination of depletion width of surface barrier detectors. Davis, C. L.; Ouseph, P. J.; O’Bryan, M. Ray // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3452 

    A simple experimental method to determine the depletion width of a surface barrier detector is discussed. An electron spectrum of Bi207 taken with a detector having depletion width less than the range of the electrons shows an additional peak. The position of the extra peak enables us to...

  • Characterization of two-gated microchannel plate framing cameras. Failor, B. H.; Gorzen, D. F.; Armentrout, C. J.; Busch, G. E. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2862 

    The overall performance of both a single- and a double-microchannel plate framing camera were measured. In the case of the double-plated device, only the front plate was gated. A short-pulse, 20-ps full width half-maximum (FWHM), uv laser was used to create photoelectrons on a time scale rapid...

  • An imaging plate system for high-pressure powder diffraction: The data processing side. Piltz, R. O.; McMahon, M. I.; Crain, J.; Hatton, P. D.; Nelmes, R. J.; Cernik, R. J.; Bushnell-Wye, G. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p700 

    The use of an imaging plate as a two-dimensional (2-D) detector removes many of the difficulties that arise in performing angle-dispersive powder diffraction at high pressures in a diamond-anvil cell. Due to the 2-D nature of the imaging plate, a substantial part of each Debye Scherrer ring is...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics