TITLE

An improved control technique for the electrochemical fabrication of scanning tunneling microscopy microtips

AUTHOR(S)
Hu Xiaotang; Liu Wenhui; Ji Guijun; Liu Anwei
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3811
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents an improved feedback control technique for the direct current (dc) electrochemical fabrication of scanning tunneling microscopy microtips. Use of the etching current as the only control signal; Electrochemical etching process; Differential feedback control method.
ACCESSION #
627499

 

Related Articles

  • Simple, variable-temperature, scanning tunneling microscope. Dubson, M. A.; Hwang, Jeeseong // Review of Scientific Instruments;Jul1992, Vol. 63 Issue 7, p3643 

    We describe a simple scanning tunneling microscope (STM) which works well from room temperature to 4 K. It is relatively easy to build, repair, or modify, and works very reliably. An unusual feature of our STM is that it is assembled without glues or solders. A list of suppliers of the...

  • A [sup 3]He refrigerated scanning tunneling microscope in high magnetic fields and ultrahigh vacuum. Kugler, M.; Renner, Ch.; Fischer, O&slash;.; Mikheev, V.; Batey, G. // Review of Scientific Instruments;Mar2000, Vol. 71 Issue 3 

    We present a scanning tunneling microscope (STM) designed to operate between 275 mK and room temperature, in magnetic fields up to 14 T and in ultrahigh vacuum (UHV). The system features a compact STM connected to an UHV compatible [sup 3]He refrigerator fitting into a bottom loading cryostat...

  • Reliable and versatile scanning tunneling microscope. Kaiser, W. J.; Jaklevic, R. C. // Review of Scientific Instruments;Apr88, Vol. 59 Issue 4, p537 

    A new scanning tunneling microscope (STM) system is described that has been operated in several environments for both topographic imaging and tunnel spectroscopy. This STM shows high resistance to the effects of vibration and thermal drift. The device is unique in its simplicity and has only...

  • A low-temperature ultrahigh-vacuum scanning tunneling microscope with rotatable magnetic field Wittneven, Chr.; Dombrowski, R.; Pan, S.H.; Wiesendanger, R. // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3806 

    Discusses the design of a low-temperature ultrahigh-vacuum scanning tunneling microscope setup with a combination of a solenoid and a split-pair magnet. Operation of the scanning tunneling microscope at temperatures down to 8K and in a rotatable magnetic field of up to 1 T; Topographic and...

  • A simple low-current scanning tunneling microscope. Dhirani, A.; Fisher, A.J.; Guyot-Sionnest, P. // Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p2953 

    Presents a rigid scanning tunneling microscope (STM) design with an implemented two-dimensional approach. Description of a current-voltage converter optimized for low-current applications; Capabilities of the microscope; Goal in designing the STM of studying self-assembled monolayers.

  • A simple low-temperature ultrahigh-vacuum scanning tunneling microscope capable of atomic... Meyer, Gerhard // Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p2960 

    Details the design of a low-temperature scanning tunneling microscope (STM). Main features including a scanner and the provision for extension of the microscope to work as a force microscope using the optical lever detection technique for force measurement.

  • Scanning tunneling microscope with a rotary piezoelectric stepping motor. Yakimov, V. N. // Review of Scientific Instruments;Feb1996, Vol. 67 Issue 2, p384 

    Describes the development of a compact scanning tunneling microscope (STM) with a novel rotary piezoelectric stepping motor for coarse positioning. Inertial slip-stick positioners; STM design; Tip to sample approaching.

  • Design considerations and performance of a combined scanning tunneling and scanning electron microscope Wiessner, A.; Kirschner, J.; Schafer, G.; Berghaus, Th. // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3790 

    Discusses the design and construction of a combination of a scanning tunneling microscope (STM) and a scanning electron microscope which is working under ultrahigh vacuum (UHV) conditions. Design concept and its realization; Description of the UHV chamber system; Influence of the electron beam...

  • Research Highlights.  // Nature Materials;Oct2008, Vol. 7 Issue 10, p764 

    The article focuses on several research findings related to the field of science. Researcher Karen Teichman and colleagues have investigated the effects of a sharp scanning tunnelling microscope tip on the charge of a single impurity atom in a host matrix. Researcher Jarrod Hanson and colleagues...