TITLE

A novel and sensitive Faraday-type magnetometer for the field range from 0to12T

AUTHOR(S)
Zhang, D.; Probst, Ch.; Andres, K.
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3755
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a Faraday-type magnetometer in which the magnetic force is measured capacitively by monitoring the displacement of a spring-suspended quartz sample holder. Use of a double gradient coil in order to compensate the force on the empty sample holder; Ultimate sensitivity of the magnetometer.
ACCESSION #
627477

 

Related Articles

  • Quality Control of Cores Made of Nanocrystalline Alloys Intended for Primary Transducers of a Drill-Hole Magnetometer–Inclinometer. Astrakhantsev, Yu. G.; Korzunin, G. S.; Lavrent'ev, A. G.; Potapov, A. P.; Sherendo, T. A.; Shulika, V. V. // Russian Journal of Nondestructive Testing;Apr2004, Vol. 40 Issue 4, p264 

    The influence of different types of thermal magnetic treatment of ferroprobe cores made of the Fe73.5Cu1Nb3Si13.5B9 nanocrystalline alloy on the characteristics of primary transducers of a drill-hole magnetometer has been studied. The informative parameters of the Barkhausen effect (a stepwise...

  • A low field superconducting quantum interference device magnetometer for dynamic measurements Magnusson, J.; Djurberg, C.; Granberg, P.; Nordblad, P. // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3761 

    Describes a superconducting quantum interference device magnetometer system for low field static and dynamic susceptibility measurements. Reduction of the residual fluid in the sample space; Generation of a highly stable dc magnetic field by a small superconducting solenoid working in the...

  • Improvement of sensitivity of the vibrating reed magnetometer. Richter, H. J.; Hempel, K. A.; Pfeiffer, J. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1388 

    A very-high-sensitivity magnetometer is described in detail. The sensitivity of the apparatus is typically of the order of 10[sup -9] A cm²/√Hz, so that changes in magnetic moment of 10[sup -10] A cm² can be detected. The magnetic moment can be calculated by simulation of the...

  • High-sensitivity magnetometry: An experimental null test of Ampère’s law. Gerber, C. J.; Chernikov, M. A.; Ott, H. R. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p793 

    A prototype low-frequency ac magnetometer with a sensitivity to circular magnetic induction of (9±5)×10-15 T/[Square_Root]Hz is described. Using this device we confirm Ampère’s law at 1.24 K setting an upper limit for possible deviations expressed in terms of the photon mass:...

  • A sample holder design and calibration technique for the quantum design magnetic properties... Lewis, L.H.; Bussmann, Konrad M. // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3537 

    Discusses a sample holder design and calibration technique used to obtain accurate magnetic-moment values from compact, low-susceptibility samples measured with the quantum design magnetic properties measurement system superconducting quantum interference device (SQUID) magnetometer. Overview...

  • High-Field Vibrating-Sample Magnetometer.  // Physics Today;Oct90, Vol. 43 Issue 10, p107 

    Reviews a computer controlled, high-field, vibrating-sample magnetometer system from Janis Research.

  • Self-oscillating rubidium magnetometer using nonlinear magneto-optical rotation. Schwindt, P. D. D.; Hollberg, L.; Kitching, J. // Review of Scientific Instruments;Dec2005, Vol. 76 Issue 12, p126103 

    The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to...

  • Composite bimetallic gasket and compact mechanical anvil retainer for magnetic measurements in a diamond-anvil cell to 30 GPa. Ishizuka, Mamoru // Review of Scientific Instruments;Dec2005, Vol. 76 Issue 12, p123902 

    A composite gasket was designed for diamond-anvil cells where the load was supported mainly by the inner part made of NiCrAl with a diameter slightly larger than the culet of the anvil. A BeCu girdle encased the NiCrAl washer and prevented it from fracturing. The thickness of the gasket was...

  • Rotating sample magnetometer for precise, real time differential measurements. Zawilski, Bartosz M.; Maillard, Denis L. E.; Geoffroy, Olivier; Dufeu, Didier // Review of Scientific Instruments;Jan2006, Vol. 77 Issue 1, p015102 

    In this paper we present the development of a rotating sample magnetometer (RSM) for real time differential magnetic moment measurement. The high accuracy and simplicity of the described apparatus allow reliable and fast magnetic characterization of samples with small magnetic moment. This...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.