TITLE

A quartz quasimonolith for absolute x-ray wavelength measurements

AUTHOR(S)
Klopfel, D.; Holzer, G.; Forster, E.; Beiersdorfer, P.
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3669
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Shows the construction of a quasimonolithic crystal consisting of two offset, parallel-mounted quartz crystals for determining the wavelengths of x-ray transitions on an absolute scale without the need for reference lines. Design and organization of the quasimonolith crystal device; Determination of the relevant parameters and their corresponding uncertainties.
ACCESSION #
627449

 

Related Articles

  • Comparison of a Resonant Mirror Biosensor (IAsys) and a Quartz Crystal Microbalance (QCM) for the Study on Interaction between Paeoniae Radix 801 and Endothelin-1. Jiadong Huang; Qing Lin; Jinghua Yu; Shenguang Ge; Jing Li; Min Yu; Zixia Zhao; Xinsheng Wang; Xiuming Zhang; Xiaorui He; Liang Yuan; Huijun Yin; Osa, Tetsuo; Chen, Keji; Qiang Chen // Sensors (14248220);2008, Vol. 8 Issue 12, p8275 

    A resonant mirror biosensor, IAsys, and a quartz crystal microbalance (QCM) are known independently as surface sensitive analytical devices capable of label-free and in situ bioassays. In this study, an IAsys and a QCM are employed for a new study on the action mechanism of Paeoniae Radix 801...

  • Low-frequency SMT crystal.  // Electronics Now;Jul93, Vol. 64 Issue 7, p24 

    Presents Ralton Electronics Corp.'s Model RSM-200, tuning fork-shaped quartz crystals. Frequency generated; Packaging; Features; Applications; Availability.

  • Disequilibrium partitioning of oxygen isotopes associated with sector zoning in quartz. Onasch, Charles M.; Vennemann, Torsten W. // Geology;Dec95, Vol. 23 Issue 12, p1103 

    Presents evidence that large variations in delta18O values in a zoned vein quartz crystal are the result of disequilibrium partitioning between fluid and crystal. Explanation on sector zoning; Factors causing disequilibrium.

  • Piezoelectrically forced vibrations of rectangular SC-cut quartz plates. Lee, P.C.Y.; Lin, W.S. // Journal of Applied Physics;6/15/1998, Vol. 83 Issue 12, p7822 

    Provides information on a study obtaining closed form solutions of free and forced vibrations of doubly rotated SC-cut quartz plates. Methodology used to conduct the study; Information on two-dimensional first-order equations; Description of forced vibrations; Findings of the study.

  • Quartz crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid... Rodahl, Michael; Hook, Fredrik; Krozer, Anatol; Brzezinski, Peter; Kasemo, Bengt // Review of Scientific Instruments;Jul1995, Vol. 66 Issue 7, p3924 

    Discusses the construction of an experimental setup for simultaneous measurements of the frequency, the absolute Q factor, and the amplitude of oscillation of a quartz crystal microbalance (QCM). Traditional use of the QCM in vacuum and in gaseous environments; Use of two crystals with...

  • 1/f noise in quartz crystal resonators in relation to acoustic losses and frequency dispersion. Planat, M.; Gagnepain, J. J. // Applied Physics Letters;3/2/1987, Vol. 50 Issue 9, p510 

    The 1/f frequency fluctuation of quartz crystal resonators between liquid helium and room temperature is investigated in relation with acoustic attenuation. Large attenuation is observed at 50 K, due to ionic Na+ impurity relaxation, at 20 K, corresponding to the interaction of the sound wave...

  • Capability analysis of quartz crystal manufacturing processes. Dieste Velasco, M.I.; Vicente, J. // Transactions of the Institute of Measurement & Control;2002, Vol. 24 Issue 4, p289 

    The quartz crystals manufacturing process is influenced by several factors that have a great influence in the frequency behaviour of the crystals. Since it is necessary to develop designs with very strict specifications related to frequency stability, it is important to have a good knowledge of...

  • Determination of flux ionization fraction using a quartz crystal microbalance and a gridded... Green, K.M.; Hayden, D.B.; Juliano, D.R; Ruiz, D.N. // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4555 

    Reports on the determination of flux ionization fraction using a quartz crystal microbalance (QCM) and a gridded energy analyzer in an ionized magnetron sputtering system. Mounting of the sensor on a linear motion; Introduction of radio-frequency power through a coil; Determination of the metal...

  • Oscillator Boasts Low Phase Noise And Aging Up To 1.5 GHz. Morrison, David G. // Electronic Design;8/19/2002, Vol. 50 Issue 17, p33 

    Focuses on the VFT-5 crystal oscillator that employs unique methods for frequency multiplication and for vacuum sealing the quartz crystals. High-frequency clocking requirements of Sonet and other optical networking applications; Frequencies of the device; Range of phase noise; Temperature...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics