TITLE

Electronics for He-Ne-I[sub 2] stabilized laser with digital control

AUTHOR(S)
Lazar, Josef; Cip, Ondrej
PUB. DATE
October 1997
SOURCE
Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3660
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents the construction of He-Ne-I[sub2] stabilized laser electronics with digital control by a personal computer. Development of the system to work with a compact laser head as a wavelength standard for metrology of lengths; Compact construction and portability of the electronic device; Simplified schematic of the system.
ACCESSION #
627445

 

Related Articles

  • Absolute calibration of imaging plate for GeV electrons. Nakanii, N.; Kondo, K.; Yabuuchi, T.; Tsuji, K.; Tanaka, K. A.; Suzuki, S.; Asaka, T.; Yanagida, K.; Hanaki, H.; Kobayashi, T.; Makino, K.; Yamane, T.; Miyamoto, S.; Horikawa, K. // Review of Scientific Instruments;Jun2008, Vol. 79 Issue 6, p066102 

    An imaging plate has been used as a useful detector of energetic electrons in laser electron acceleration and laser fusion studies. The absolute sensitivity of an imaging plate was calibrated at 1 GeV electron energy using the injector Linac of SPring-8. The sensitivity curve obtained up to 100...

  • Improved spectral properties of diode lasers Milic, Dragana; Lu, Weijian; Hoogerland, Maarten D.; Blacksell, Michael; Baldwin, Kenneth G.H.; Buckman, Stephen J. // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3657 

    Reports on several complementary methods for improving the stability of a free running diode laser. Construction of a stable power supply to reduce the main frequency and rf noise; Long term drift of the laser frequency; Development of a lock-in amplifier to be combined with a simple...

  • A system of excilamps on xenon dimers for a flow photoreactor. Shits, D.; Skakun, V.; Tarasenko, V. // Instruments & Experimental Techniques;Sep2008, Vol. 51 Issue 5, p759 

    A system consisting of ten excilamps on xenon dimers for a flow photoreactor is designed. The total radiation power at a 172-nm wavelength was ∼120 W, when the radiation power density from the excilamp radiator surface was ∼15 mW/cm2.

  • New all-fiber velocimeter. Jidong Weng; Hua Tan; Shaolou Hu; Yun Ma; Xiang Wang // Review of Scientific Instruments;Sep2005, Vol. 76 Issue 9, p093301 

    A new all-fiber velocity interferometer system for any reflector (AFVISAR) was developed. It was conceived and realized with the purpose of using it as the basic measuring element of a complete system for multiple point velocity measurements. Its main features are that it works at 532 nm and...

  • New counting system for detection of charged particles: application to ions generated by a pulsed laser beam. Ichimura, S.; Goto, K.; Kokubun, K.; Shimizu, H.; Hashizume, H. // Review of Scientific Instruments;Apr90, Vol. 61 Issue 4, p1192 

    A new counting system for charged particles, which is suitable for the counting of pulse trains arriving in a short time, was constructed. The system is composed of a microchannel-plate intensifier, a CCD camera, a frame buffer, a particle counter, and a personal computer. Ion (or electron)...

  • Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector. Moody, J. D.; Clancy, T. J.; Frieders, G.; Celliers, P. M.; Ralph, J.; Turnbull, D. P. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflector...

  • Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam. Davies, A.; Haberberger, D.; Boni, R.; Ivancic, S.; Brown, R.; Froula, D. H. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic...

  • New Products. Rubin, Lawrence G. // Physics Today;May2005, Vol. 58 Issue 5, p76 

    Presents information on several lasers and optical instruments. Cube lasers from Coherent; Fiber-coupled femtosecond lasers from Thorlabs; Diode laser spectroscopy from TeachSpin.

  • GROUND RADIAL SYSTEM FOR HF VERTICAL ANTENNAS.  // QST;Jan2005, Vol. 89 Issue 1, p58 

    Features the new Ground Radial or Counterpoise System for HF Vertical antennas, the EZRadial offered by RadialWave LLC. Components of the product; Usability; Pricing; Contact information.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics