TITLE

Inhaler device selection: Special considerations in elderly patients with chronic obstructive pulmonary disease

AUTHOR(S)
Barrons, Robert; Pegram, Angela; Borries, Alaina
PUB. DATE
July 2011
SOURCE
American Journal of Health-System Pharmacy;7/1/2011, Vol. 68 Issue 13, p1221
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose. Special considerations in the selection of medication inhaler devices for elderly patients with chronic obstructive pulmonary disease (COPD) in the ambulatory care setting are reviewed. Summary. Substantial deficiencies in inhaler device technique and medication adherence are evident in patients with COPD, leading to suboptimal health outcomes. As the prevalence of COPD rises with age, elderly patients pose special challenges with regard to inhaler device selection. In elderly patients with sufficient cognitive function, manual dexterity, and hand strength, the most influential factors in inhaler selection are cost reimbursement, device availability, device convenience, and patient preference. Cost reimbursement may be a deciding factor in device selection, as nearly all elderly patients are Medicare beneficiaries. Nebulizers provide a cost-effective alternative to pressurized metered-dose inhaler (pMDI) and dry powder inhaler (DPI) devices. DPI device availability is limited to "controller" medications, while pMDI devices and nebulizers provide complete symptomatic coverage. Multiple-dose DPIs offer the convenience of rapid medication administration, ease of handling, and integral dose counters. Given the availability and expenses of medication devices, ambulatory patients may prefer combining the convenience of a hand-held inhaler (i.e., pMDI) as a rescue medication during the active hours of midday with the cost savings of a nebulized controller medication in the morning and at night. Conclusion. In elderly patients with sufficient cognitive function, manual dexterity, and hand strength, the most important factors in inhaler device selection are cost reimbursement issues, device availability, device convenience, and patient preference. Pharmacist knowledge of appropriate inhaler technique, competent patient education and demonstration, and followup assessment are instrumental in optimizing device competency and medication adherence.
ACCESSION #
62548790

 

Related Articles

  • Effectiveness of computerized clinical decision support systems for asthma and chronic obstructive pulmonary disease in primary care: a systematic review. Fathima, Mariam; Peiris, David; Naik-Panvelkar, Pradnya; Saini, Bandana; Armour, Carol Lyn // BMC Pulmonary Medicine;2014, Vol. 14 Issue 1, p1 

    Background The use of computerized clinical decision support systems may improve the diagnosis and ongoing management of chronic diseases, which requires recurrent visits to multiple health professionals, disease and medication monitoring and modification of patient behavior. The aim of this...

  • Breath-Actuated Nebulizer for Patients With Exacerbation of COPD: Efficiency and Cost. Hui-Ling Lin, Hui-Ling; Fink, James B. // Respiratory Care;Sep2012, Vol. 57 Issue 9, p1524 

    The author discusses a study by Haynes which examined the clinical response of the breath-actuated nebulizer (BAN) and small-volume nebulizer (SVN) on patients with exacerbation of chronic obstructive pulmonary disease (ECOPD). Improved inspiratory capacity (IC) and lower respiratory rate may be...

  • Understanding the impact of inhaler technique on asthma and COPD. Hickey, Steven // Nurse Prescribing;OCt2014, Vol. 12 Issue 10, p492 

    Ineffective inhaler technique is a common problem that can lead to poor disease management and an increase in the frequency of exacerbations. It is not always down to patients choosing to use inhalers in an inappropriate way, as evidence suggests health professionals are often found to be...

  • Keeping IT in balance.  // Modern Healthcare;7/12/2010, Vol. 40 Issue 28, p32 

    The article discusses the use of computerized clinical decision-support systems at Allegiance Health, a regional hospital and health system based in Jackson, Michigan. Jonathan Sykes, the hospital's chief medical information officer and director of clinical information systems, has led the...

  • Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support.  // Journal of the American Medical Informatics Association;Jul2011, Vol. 18 Issue 4, p479 

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to...

  • Adapting Aerosol Devices to the Needs of the Geriatric Patient. Messenger, Robert // AARC Times;Jan2012, Vol. 36 Issue 1, p14 

    The article discusses the complexities in using aerosol devices in treating patients with chronic obstructive pulmonary disease (COPD). It notes that the treatment for such disease has been complicated by the presence of comorbidities. Meanwhile, it suggests that respiratory therapists need to...

  • Duplicate Laboratory Test Reduction Using a Clinical Decision Support Tool. Procop, Gary W.; Yerian, Lisa M.; Wyllie, Robert; Harrison, A. Marc; Kottke-Marchant, Kandice // American Journal of Clinical Pathology;May2014, Vol. 141 Issue 5, p718 

    Objectives: Duplicate laboratory tests that are unwarranted increase unnecessary phlebotomy, which contributes to iatrogenic anemia, decreased patient satisfaction, and increased health care costs. Materials and Methods: We employed a clinical decision support tool (CDST) to block unnecessary...

  • Knowledge of and technique for using inhalation devices among asthma patients and COPD patients. Souza, Maria Luiza de Moraes; Meneghini, Andrea Cristina; Ferraz, Érica; Vianna, Elcio Oliveira; Borges, Marcos Carvalho // Jornal Brasileiro de Pneumologia;sep2009, Vol. 35 Issue 9, p824 

    Objective: To evaluate knowledge of and techniques for using prescribed inhalation devices among patients with asthma or COPD treated at a tertiary teaching hospital. Methods: Patients were assessed after medical visits, and their physicians were blinded to this fact. Patients were asked to...

  • Another plausible explanation for mist inhaler's toxicity. Seed, Martin J.; Cullinan, Paul; Agius, Raymond // BMJ: British Medical Journal (Overseas & Retired Doctors Edition;7/30/2011, Vol. 343 Issue 7817, p223 

    A letter to the editor is presented in response to the article "Mortality associated with tiotropium mist inhaler in patients with chronic obstructive pulmonary disease: systematic review and meta-analysis of randomised controlled trials," by S. Singh, Y.K. Loke, P.L. Enright, C.D. Furberg in...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics