TITLE

Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy: Comparison between continuous and point-mass models

AUTHOR(S)
Rodrı´guez, Toma´s R.; Garcı´a, Ricardo
PUB. DATE
March 2002
SOURCE
Applied Physics Letters;3/4/2002, Vol. 80 Issue 9, p1646
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We discuss the influence of high-order frequency components in the operation of an amplitude modulation atomic-force microscope (AFM). A comparative study of point-mass and continuous models is performed to describe the tip motion. The tip-surface interaction force excites high-order frequency components whenever a higher harmonic of the excitation force is close to an eigenmode of the cantilever beam. The strength of those components depends on the set point amplitude and the fundamental resonance frequency of the cantilever. However, for standard operating conditions with quality factors in the 10²-10³ range, higher-order components are about three orders of magnitude smaller than the component at the excitation frequency. We conclude that point-mass models are suitable to describe the operation of a tapping-mode AFM in air environments.
ACCESSION #
6220543

 

Related Articles

  • Frequency response of an atomic force microscope in liquids and air: Magnetic versus acoustic excitation. Herruzo, Elena T.; Garcia, Ricardo // Applied Physics Letters;10/1/2007, Vol. 91 Issue 14, p143113 

    We discuss the dynamics of an amplitude modulation atomic force microscope in different environments such as water and air. Experiments, analytical expressions, and numerical simulations show that the resonance curves depend on the excitation method used to drive the cantilever, either...

  • Enhanced compositional sensitivity in atomic force microscopy by the excitation of the first two flexural modes. Martinez, N. F.; Patil, S.; Lozano, J. R.; Garcia, R. // Applied Physics Letters;10/9/2006, Vol. 89 Issue 15, p153115 

    The authors demonstrate that the compositional sensitivity of an atomic force microscope is enhanced by the simultaneous excitation of its first two flexural eigenmodes. The coupling of those modes by the nonlinear probe-surface interactions enables to map compositional changes in several...

  • Theory of Q control in atomic force microscopy. Rodrıguez, Tomás R.; Garcıa, Ricardo // Applied Physics Letters;6/30/2003, Vol. 82 Issue 26, p4821 

    We discuss the performance of an atomic force microscope (AFM) operated in the amplitude modulation mode under a self-excitation signal, known as quality factor control (Q control). By using the point-mass description of the AFM, we provide a complete description of Q control in tapping mode...

  • Real-time detection of probe loss in atomic force microscopy. De, Tathagata; Agarwal, Pranav; Sahoo, Deepak R.; Salapaka, Murti V. // Applied Physics Letters;9/25/2006, Vol. 89 Issue 13, p133119 

    In this letter, a real-time methodology is developed to determine regions of dynamic atomic force microscopy based image where the cantilever fails to be an effective probe of the sample. Conventional imaging signals such as the amplitude signal and the vertical piezoactuation signal cannot...

  • Phase image contrast mechanism in intermittent contact atomic force microscopy. Yagun Zhao; Qian Cheng; Menglu Qian; Cantrell, John H. // Journal of Applied Physics;Nov2010, Vol. 108 Issue 9, p094311 

    A model is presented showing that phase variations in intermittent contact atomic force microscopy (IC-AFM) (tapping mode) result from variations in both conservative and dissipative forces. It is shown that when operating with constant cantilever oscillation amplitude, however, conservative...

  • Stability, resolution, and ultra-low wear amplitude modulation atomic force microscopy of DNA: Small amplitude small set-point imaging. Santos, Sergio; Barcons, Victor; Christenson, Hugo K.; Billingsley, Daniel J.; Bonass, William A.; Font, Josep; Thomson, Neil H. // Applied Physics Letters;8/5/2013, Vol. 103 Issue 6, p063702 

    A way to operate fundamental mode amplitude modulation atomic force microscopy is introduced which optimizes stability and resolution for a given tip size and shows negligible tip wear over extended time periods (∼24 h). In small amplitude small set-point (SASS) imaging, the cantilever...

  • Impact of surface charges on the solvation forces in confined colloidal solutions. Grandner, Stefan; Yan Zeng; Klitzing, Regine V.; Klapp, Sabine H. L. // Journal of Chemical Physics;10/21/2009, Vol. 131 Issue 15, p154702 

    Combining computer simulations and experiments we address the impact of charged surfaces on the solvation forces of a confined, charged colloidal suspension (slit-pore geometry). Investigations based on the colloidal-probe atomic-force-microscope technique indicate that an increase in surface...

  • Phase contrast and operation regimes in multifrequency atomic force microscopy. Santos, Sergio // Applied Physics Letters;4/7/2014, Vol. 104 Issue 14, p1 

    In amplitude modulation atomic force microscopy the attractive and the repulsive force regimes induce phase shifts above and below 90°, respectively. In the more recent multifrequency approach, however, multiple operation regimes have been reported and the theory should be revisited. Here, a...

  • Controlling bistability in tapping-mode atomic force microscopy using dual-frequency excitation. Thota, Phanikrishna; MacLaren, Scott; Dankowicz, Harry // Applied Physics Letters;8/27/2007, Vol. 91 Issue 9, p093108 

    This letter discusses an experimental method to suppress spontaneous transitions between low- and high-amplitude oscillatory responses in tapping-mode atomic force microscopy in the absence of feedback control. Here, the cantilever is excited at two frequencies and the dynamic force curves for...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics