TITLE

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

AUTHOR(S)
Carroll, Lee; Friedli, Peter; Lerch, Philippe; Schneider, Jörg; Treyer, Daniel; Hunziker, Stephan; Stutz, Stefan; Sigg, Hans
PUB. DATE
June 2011
SOURCE
Review of Scientific Instruments;Jun2011, Vol. 82 Issue 6, p063101
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 μm) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 μm range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.
ACCESSION #
62010880

 

Related Articles

  • Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source. Vernoud, Laetitia; Bechtel, Hans A.; Borondics, Ferenc; Martin, Michael C. // AIP Conference Proceedings;2/3/2010, Vol. 1214 Issue 1, p36 

    Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR...

  • Interface for time-resolved electrochemical infrared microspectroscopy using synchrotron infrared radiation. Rosendahl, Scott M.; Borondics, Ferenc; May, Tim E.; Pedersen, Tor M.; Burgess, Ian J. // Review of Scientific Instruments;Aug2011, Vol. 82 Issue 8, p083105 

    A description of a coupled electrochemical and spectrometer interface using synchrotron infrared radiation is provided. The interface described allows for the precise and accurate timing needed for time-resolved IR spectroscopic studies of electrochemical systems. The overall interface uses a...

  • Surface-selective x-ray topographic observations of mechanochemical polished silicon surfaces.... Kimura, Shigeru; Mizuki, Jun'ichiro; Matsui, Junjie; Ishikawa, Tetsuya // Applied Physics Letters;5/25/1992, Vol. 60 Issue 21, p2604 

    Demonstrates the surface-selective topographic observation using asymmetric diffraction. Tunability of synchrotron radiation; Visualization of the surface strains of mechanochemical polished silicon(001) and silicon wafers; Characterization of the surface damage of polished silicon wafers.

  • Synchrotron radiation micro-Fourier transform infrared spectroscopy applied to photoresist imaging. Ocola, L.E.; Cerrina, F. // Applied Physics Letters;8/11/1997, Vol. 71 Issue 6, p847 

    Examines the application of synchrotron radiation micro-Fourier transform infrared (FTIR) spectroscopy to photoresist imaging. Determination of the actual spot size achievable with the microscope; Use of the micro-FTIR technique for mapping chemical changes; Implications for nondestructive...

  • Experimental setup for Fourier transform infrared spectroscopy studies in condensed matter at... Bini, R.; Ballerini, R.; Pratesi, G.; Jodl, H.J. // Review of Scientific Instruments;Aug1997, Vol. 68 Issue 8, p3154 

    Describes an experimental setup for Fourier transform infrared studies in condensed matter at high pressure and low temperatures. Adaptation of a close-cycle cryostat to the sample compartment; Design and operation of the setup; Advantages of the system.

  • Have FT-IR...Will Travel. Coates, John; Reffner, John // Spectroscopy;Apr2000, Vol. 15 Issue 4, p19 

    Provides information on the evolution of portable Fourier transform-infrared (FT-IR) instruments. Implementation of on-site infrared analyzers; On-site applications for portable micro-attenuated total reflection or internal reflection; Opportunities for performing on-site infrared spectrum...

  • The application of a vacuum ultraviolet Fourier transform spectrometer and synchrotron radiation source to measurements of: V. The β(11,0) band of NO. Rufus, J.; Yoshino, K.; Thorne, A. P.; Murray, J. E.; Imajo, T.; Ito, K.; Matsui, T. // Journal of Chemical Physics;12/15/2002, Vol. 117 Issue 23, p10621 

    The β(11,0) band of NO was measured at high resolution (0.06 cm[sup -1]) by the vacuum ultraviolet Fourier transform spectrometer from Imperial College, London, using synchrotron radiation at the Photon Factory, KEK, Japan, as a continuum light source. Such resolution facilitates a line by...

  • Chemical Composition of Atherosclerotic Plaques of apoE/LDLR-Double Knockout Mice by Synchrotron Radiation FTIR Microspectroscopy. Kowalska, J.; Gajda, M.; Kwiatek, W. M.; Franczyk-Żarów, M.; Kostogrys, R. B.; Chłopicki, S.; Sandt, C.; Dumas, P. // Acta Physica Polonica, A.;Feb2012, Vol. 121 Issue 2, p555 

    Atherosclerosis is a multietiological inflammatory disease of large and medium-sized arteries of increasing incidence in westernized countries. The aim of this study was to identify the biochemical changes during the progression of atherosclerosis by synchrotron radiation Fourier transform...

  • Taxon-specific responses of Southern Ocean diatoms to Fe enrichment revealed by synchrotron radiation FTIR microspectroscopy. Sackett, O.; Armand, L.; Beardall, J.; Hill, R.; Doblin, M.; Connelly, C.; Howes, J.; Stuart, B.; Ralph, P.; Heraud, P. // Biogeosciences Discussions;2014, Vol. 11 Issue 5, p7327 

    Photosynthesis by marine diatoms contributes substantially to global biogeochemical cycling and ecosystem productivity. It is widely accepted that diatoms are extremely sensitive to changes in Fe availability, with numerous in situ experiments demonstrating rapid growth and increased export of...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics