TITLE

A two-reflection divergent differentiating critical angle refractometer

AUTHOR(S)
Guo, Wenping; Xia, Min; Li, Wei; Dai, Jie; Yang, Kecheng
PUB. DATE
May 2011
SOURCE
Review of Scientific Instruments;May2011, Vol. 82 Issue 5, p053108
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new critical angle refractometer (CAR) for high accuracy refractive index measurement of liquid has been developed. The instrument improves the accuracy by two reflections in an elongated parallelogram prism, and acquires the angular reflectivity without any angle scanning parts through introduction of a point source with a divergent beam and a charge coupled device. In addition, it employs a simple and robust measurement method that gets the critical angle by differentiating the angular reflectivity. Through investigating absorbing media with absorption index κ (the imaginary part of refractive index) from 0 to 10-2.1, the theoretical calculation shows that the proposed two-reflection CAR would outperform the traditional one-reflection CAR on lowering the principal error from the differentiation method and improving the ability of getting the critical angle. By testing two typical liquids-salt-water solution and milk, the preliminary experiment indicates that this two-reflection divergent differentiating critical angle refractometer is feasible and of high accuracy.
ACCESSION #
62010744

 

Related Articles

  • A new simple compact refractometer applied to measurements of air density fluctuations Fang, H.; Juncar, P. // Review of Scientific Instruments;Jul99, Vol. 70 Issue 7, p3160 

    Describes a refractometer for air refractive index measurements. Space thickness of Zerodur; Metrological characteristics of the interferometer in vacuum; Use of air density to make buoyancy corrections; Laser diode frequency reference; Beat frequency and stability of the Fabry-Perot filter;...

  • Simple laser refractometer for liquids. Zaidi, A. A. // Review of Scientific Instruments;Jul1988, Vol. 59 Issue 7, p1153 

    A method for the determination of the refractive index of liquids using a He-Ne laser is presented. The experimental setup is simple and utilizes equipment which is normally available in most optics laboratories. Measurements carried out on water and several organic liquids are reported. The...

  • Measurement of refractive indices of fibers with regular or irregular transverse sections and having a skin-core structure. Kabeel, M. A. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2950 

    Multiple-beam Fizeau fringes crossing fibers of different cross-sectional shapes and having a skin-core structure are studied to determine the refractive indices of the two layers. These fibers are of circular, rectangular, triangular, trilobal, elliptical, kidney, and dog-bone cross-sectional...

  • Portable Digital Refractometer.  // Laboratory Equipment;Jun2001, Vol. 38 Issue 2, p1 

    Deals with a handheld portable AR200 Refractometer from Leica Microsystems Inc. Features of the laboratory equipment; Utilization of linear scanned array imaging; Availability of alternate scales via custom programming.

  • A novel interferometric liquid refractometer. Webb, D. J.; Tatam, R. P.; Jackson, D. A. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3347 

    We describe a novel form of liquid refractometer in which the optical length of a cavity containing the liquid is monitored interferometrically.

  • NEW MATERIALS AND COMPONENTS. Farmer, Barry L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p258 

    Presents materials and components for scientific instruments and apparatus. Intelligent link; Noncontact milliammeter; Optical power meter; Moisture analysis; Pulse-delay generator; Optical mount; Lubricant; Phototherapy radiometer; Custom charge coupled devices; Miniature process manometer.

  • High-speed, high-sensitivity aerosol fluorescence spectrum detection using a 32-anode photomultiplier tube detector. Pan, Yong-le; Cobler, Patrick; Rhodes, Scott; Potter, Alexander; Chou, Tim; Holler, Stephen; Chang, Richard K.; Pinnick, Ronald G.; Wolf, Jean-Pierre // Review of Scientific Instruments;Mar2001, Vol. 72 Issue 3, p1831 

    We employ a 32-anode photomultiplier tube (PMT) in a fluorescence detection system and demonstrate its ability to record broad fluorescence spectra at frame rates in excess of 1.4x10[sup 3] Hz, which is 56x faster than the frame rate of an intensified charge coupled device detector. The...

  • Simultaneous elemental analysis system using laser induced breakdown spectroscopy. Body, Doug; Chadwick, Bruce L. // Review of Scientific Instruments;Mar2001, Vol. 72 Issue 3, p1625 

    A new instrumentation variation on laser induced breakdown spectroscopy (LIBS) is presented that allows simultaneous determination of all detectable elements using a multiple spectrograph and synchronous, multiple charge coupled device spectral acquisition system. The device has been designed to...

  • Calibration procedures for charge-coupled device x-ray detectors Barna, S.L.; Bama, S. L.; Tate, M.W.; Tate, M. W.; Gruner, S.M.; Gruner, S. M.; Eikenberry, E.F.; Eikenberry, E. F. // Review of Scientific Instruments;Jul99, Vol. 70 Issue 7, p2927 

    Describes calibration procedures for charge-coupled device (CCD) x-ray detectors. Accuracy of the calibration procedure; Procedure for removal of zingers; Signal accumulation by x-ray detectors even when unexposed to radiation; Correction of geometric image distortions; Elimination of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library