TITLE

Comparison of Whole-Blood Metal Ion Levels in Four Types of Metal-on-Metal Large-Diameter Femoral Head Total Hip Arthroplasty: The Potential Influence of the Adapter Sleeve

AUTHOR(S)
Lavigne, Martin; Beizile, Etienne L.; Roy, Alain; Morin, François; Amzica, Traian; Vendittoli, Pascal-André
PUB. DATE
May 2011
SOURCE
Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p128
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Metal-on-metal bearings, as used in total hip arthroplasty prostheses that have a large-diameter femoral head, were proposed as an option for treating young and active patients with degenerative hip disorders. Despite the theoretical improved performance of large metal articulations with regard to wear, metal ion levels produced by total hip arthroplasty prostheses in which a large-diameter femoral head is used have not been thoroughly evaluated. Methods: From 173 eligible patients, 144 patients were allocated to undergo a unilateral total hip arthroplasty with use of metal-on-metal components and a large-diameter femoral head. The purpose of this study was to compare the amount of metal ion release (chromium, cobalt, and titanium) from four different types of prostheses from four different implant manufacturers (Biomet, DePuy, Smith & Nephew, and Zimmer). Results: For cobalt ion levels, a significant difference was found between the different types of total hip arthroplasty prostheses with a large-diameter femoral head at three, six, twelve, and twenty-four months, but only in male patients or patients with a femoral head size of 50 mm or greater. The highest mean cobalt levels at all follow-up periods were observed with the Zimmer implant and the lowest with the Biomet implant. Titanium ion levels were highest in the Zimmer group at all follow-up periods, whereas no difference between groups was found for chromium. At the most recent follow up, one hip was revised after the development of an adverse local tissue reaction. Of concern was the observation at the time of revision surgery of black metallic deposits inside the adapter sleeve and on the prosthetic femoral neck. Conclusions: This investigation revealed that metal ion release differs greatly between various total hip arthroplasty implants with a large-diameter femoral head. The sources of metal ion production are numerous, but it is hypothesized that wear and corrosion at the junction between the adapter sleeve and the femoral stem in some patients may be responsible for the elevated cobalt ion levels that were found in the Zimmergroup. On the other hand, an adapter sleeve made of titanium, such as the one used with the Biomet large-diameter-head total hip arthroplasty, is an unlikely contributor to the release of cobalt ions. Current technology or design of some total hip arthroplasty systems that make use of a large-diameter femoral head may not yet allow the use of modular large heads with a metal-on-metal articulation, especially in young, active male patients whose activities generate high loads at the hip joint. Further research is needed to better understand the favorable design characteristics of modular junctions in metal-on-metal total hip arthroplasty implants that make use of large-diameter femoral heads. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
60523748

 

Related Articles

  • Revision Total Hip Arthroplasty Performed Through the Hueter Interval. Mast, Nicholas H.; Laude, Frédéric // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p143 

    Revision total hip arthroplasty through the direct anterior approach is technically challenging but offers some advantages in exposure of the acetabulum. This study presents a retrospectively reviewed consecutive series of fifty-one patients who underwent revision total hip arthroplasty through...

  • Evolution in Hip Resurfacing Design and Contemporary Experience with an Uncemented Device. Spencer, Robert F. // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p84 

    The concepts of surface replacement of the hip and metal-on-metal articulation date back to the 1930s, and recent hip resurfacing designs have been more successful than their predecessors. Experience with the Cormet device followed initial collaboration with Mr. Derek McMinn. Both hybrid...

  • A Survey on the Prevalence of Pseudotumors with Metal-on-Metal Hip Resurfacing in Canadian Academic Centers. Beaulé, Paul E. // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p118 

    Background: Metal-on-metal bearings for hip arthroplasty have been in clinical use for over twenty years with excellent clinical results reported worldwide. A small percentage (<1%) of patients have developed an inflammatory response, and a more severe inflammatory response termed pseudotumor...

  • Fracturas periprotésicas de cadera. Sauri-Arce, J. C. A.; Azcona-Cervera, R. // Acta Ortopedica Mexicana;Mar/Apr2014, Vol. 28 Issue 2, p77 

    The incidence rate of peripros-thetic fractures has increased in the past decade. Osteolysis, age and preoperative function are factors that influence morbidity. Treatment options include conservative and surgical treatment. Objectives: To conduct a study analyzing the functional results of the...

  • Residual Groin Pain at a Minimum of Two Years After Metal-on-Metal THA with a Twenty-eight-Millimeter Femoral Head, THA with a Large-Diameter Femoral Head, and Hip Resurfacing. Lavigne, Martin; Laffosse, Jean-Michel; Ganapathi, Muthu; Girard, Julien; Vendittoli, Pascal // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p93 

    Background: Groin pain may persist in up to 4.3% of patients after total hip arthroplasty and up to 18% of patients one year after hip resurfacing. The incidence of this problem after total hip arthroplasty with a large-diameter femoral head is unknown. Methods: We analyzed the natural history...

  • The Mayo cementless femoral component in active patients with osteoarthritis. GOEBEL, DIETMAR; SCHULTZ, WOLFGANG // Hip International;Jul-Sep2009, Vol. 19 Issue 3, p206 

    This prospective study reports the clinical and radiological results of a single-surgeon series using the mayo conservative hip stem in a district hospital. 30 total hip arthroplasties were performed in 26 physically active patients. There were 18 women and 8 men, with a mean age of 57.4 years...

  • Laboratory studies on the tribology of hard bearing hip prostheses: ceramic on ceramic and metal on metal. Vassiliou, K.; Scholes, S. C.; Unsworth, A. // Proceedings of the Institution of Mechanical Engineers -- Part H;Jan2007, Vol. 221 Issue 1, p11 

    Total hip replacements offer relief to a great many patients every year around the world. With an expected service life of around 25 years on most devices, and with younger and younger patients undergoing this surgery, it is of great importance to understand the mechanisms of their function....

  • The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements. Brockett, Claire; Harper, Phil; Williams, Sophie; Isaac, Graham H.; Dwyer-Joyce, Rob S.; Zhongmin Jin; Fisher, John // Journal of Materials Science: Materials in Medicine;Apr2008, Vol. 19 Issue 4, p1575 

    Large diameter metal-on-metal bearings (MOM) are becoming increasingly popular, addressing the needs of young and more active patients. Clinical data has shown excellent short-to-mid-term results, though incidences of transient squeaking have been noted between implantation and up to 2 years...

  • Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time. Catelas, I.; Campbell, P. A.; Bobyn, J. D.; Medley, J. B.; Huk, O. L. // Proceedings of the Institution of Mechanical Engineers -- Part H;Feb2006, Vol. 220 Issue 2, p195 

    Detailed characterization of wear particles is necessary to understand better the implant wear mechanisms and the periprosthetic tissue response. The purposes of the present study were to compare particle characteristics of current with older designs of metal-on-metal (MM) total hip replacements...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics