ABSTRACT
Background: The use of highly cross-linked polyethylene is now commonplace in total hip arthroplasty. Hip simulator studies and short-term in vivo measurements have suggested that the wear rate of highly cross-linked polyethylene is significantly less than that of conventional ultra-high molecular weight polyethylene. However, long-term data to support its use are limited. The aim of this study was to compare the intermediate-term steady-state wear of highly cross-linked polyethylene compared with that of conventional ultra-high molecular weight polyethylene acetabular liners in a pro- spective, double-blind, randomized controlled trial with use of radiostereometric analysis. Methods: Fifty-four patients were randomized to receive hip replacements with either conventional ultra-high molecular weight polyethylene acetabular liners (Zimmer) or highly cross-linked polyethylene liners (Longevity; Zimmer). All patients received a cemented, collarless, polished, tapered femoral component (CPT; Zimmer) and an uncemented acetabular component (Trilogy; Zimmer). Clinical outcomes were assessed and the three-dimensional penetration of the head into the socket was determined for a minimum of seven years. Linear regression was used to calculate the steady-state wear rate following the creep-dominated penetration seen during the first year. Results: At a minimum of seven years postoperatively, the mean total femoral head penetration was significantly lower in the highly cross-linked polyethylene group (0.33 mm; 95% confidence interval [Cl], ±0.10 mm) than it was in the ultra- high molecular weight polyethylene group (0.55 mm; 95% Cl, ±0.10 mm)(p = 0.005). The mean steady-state wear rate of highly cross-linked polyethylene was 0.005 mm/yr (95% CI, ±0.015 mm/yr), compared with 0.037 mm/yr (95% Cl, ±0.019 mm/yr) for conventional ultra-high molecular weight polyethylene (p = 0.007). No patient in the highly cross-linked polyethylene group had a wear rate above the osteolysis threshold of 0.1 mm/yr, compared with 9% of patients in the ultra-high molecular weight polyethylene group. Conclusions: This study demonstrates that highly cross-linked polyethylene has a significantly lower steady-state wear rate compared with that of conventional ultra-high molecular weight polyethylene. Longer-term follow-up is required to determine if this will translate into improved clinical performance and longevity of these implants.
ACCESSION #
60439341

 

Related Articles

  • Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty. Jiri Gallo; Vitezslav Havranek; Jana Zapletalova // International Orthopaedics;Jan2010, Vol. 34 Issue 1, p19 

    Abstract  We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression...

  • Sudden onset of polyethylene wear seen in acetabular liners. Beadling, Lee; Press, Robert // Orthopaedics Today Europe;Jul/Aug2010, Vol. 13 Issue 4, p10 

    The article reports on a study which found symptoms of a polyethylene liner's degradation and significant osteolysis at the femoral and acetabular side of the total hip arthroplasty (THA) 13 to 14 years after the procedure.

  • TOTAL HIP REPLACEMENT WITH A CEMENTLESS ACETABULAR COMPONENT AND A CEMENTED FEMORAL COMPONENT IN PATIENTS YOUNGER THAN FIFTY YEARS OF AGE. Kim, Young-Hoo; Kook, H.-K.; Kim, J.-S. // Journal of Bone & Joint Surgery, American Volume;May2002, Vol. 84-A Issue 5, p770 

    Background: We have been using hybrid total hip arthroplasty (a cementless acetabular component and a cemented stem) in young patients. The purpose of this study was to determine the prevalence of aseptic loosening, polyethylene wear, and osteolysis after the use of this technique. Methods: We...

  • CORR Insights: There Are No Differences in Short- to Mid-term Survivorship Among Total Hip-bearing Surface Options: A Network Meta-analysis. Porcher, Raphaël // Clinical Orthopaedics & Related Research;Jun2015, Vol. 473 Issue 6, p2042 

    The article focuses on the use of network meta-analysis (NMA) method in Total Hip Arthroplasty (THA). It discusses the intervention of homogeneity in NMA involving treatments and states that NMA has pointed out several shortcomings in orthopaedic treatments. It focuses on the lack of randomized...

  • Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Koh, Kyoung; Moon, Young-Wan; Lim, Seung-Jae; Lee, Hyun; Shim, Jae; Park, Youn-Soo // Archives of Orthopaedic & Trauma Surgery;Nov2011, Vol. 131 Issue 11, p1591 

    Introduction: Revision surgery in patients showing polyethylene wear and acetabular osteolysis without visible acetabular cup loosening involves the difficult decision of whether to revise only the liner or both the cup and the liner. The purpose of this study is to compare the outcomes of...

  • The Biology of Aseptic Osteolysis. G Holt // Clinical Orthopaedics & Related Research;Jul2007, Vol. 460 Issue 1, p240 

    Total hip arthroplasty is one of the most commonly performed and successful elective orthopaedic procedures. However, numerous failure mechanisms limit the long-term success including aseptic osteolysis, aseptic loosening, infection, and implant instability. Aseptic osteolysis and subsequent...

  • Modular Insert Exchange in Knee Arthroplasty for Treatment of Wear and Osteolysis. William Griffin // Clinical Orthopaedics & Related Research;Nov2007, Vol. 464 Issue 1, p132 

    Wear and osteolysis have been successfully treated by modular polyethylene exchange in revision hip arthroplasty. How ever, studies of the same approach in revision knee arthroplasty have not provided similar results. We evaluated the results of isolated polyethylene exchange for wear and/or...

  • High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty. Korovessis, Panagiotis; Repantis, Thomas; Zafiropoulos, Andreas // Archives of Orthopaedic & Trauma Surgery;May2011, Vol. 131 Issue 5, p603 

    Background and purpose: The Zweymüller-Plus system (SL-Plus stem, Bicon-Plus threaded cup) for primary total hip arthroplasty (THA) was introduced in 1993, as a successor of the Alloclassic THA with a few modifications in the conical stem shape and a new biconical threaded cup with a...

  • Short-term wear of Japanese highly cross-linked polyethylene in cementless THA. Miyanishi, Keita; Hara, Toshihiko; Kaminomachi, Shigekazu; Maekawa, Masayuki; Iwamoto, Mikio; Torisu, Takehiko // Archives of Orthopaedic & Trauma Surgery;Sep2008, Vol. 128 Issue 9, p995 

    Production of polyethylene wear from acetabular liners is thought, in part, to mediate the periprosthetic osteolysis. This study examined the in vivo wear performance of Japanese highly cross-linked polyethylene (Aeonian) in cementless total hip arthroplasty. Ninety-five hips received a highly...