TITLE

Nuclear science at GEANIE

AUTHOR(S)
Younes, W.; Becker, J. A.; Bernstein, L. A.; Garrett, P. E.; McGrath, C. A.; McNabb, D. P.; Johns, G. D.; Nelson, R. O.; Wilburn, W. S.
PUB. DATE
July 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 529 Issue 1, p192
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
GEANIE at LANSCE/WNR combines the precision energy resolution of germanium detectors with the advantages of a “white” source providing neutrons with energies 1
ACCESSION #
6030014

 

Related Articles

  • Cross section measurements for Pr( n,γ)Pr reaction at neutron energies from 13.5 to 14.8 MeV. Luo, Junhua; Han, Jiuning; Liu, Rong; Jiang, Li // Journal of Radioanalytical & Nuclear Chemistry;Jul2012, Vol. 293 Issue 1, p261 

    Activation cross-sections were measured for the Pr( n,γ)Pr reaction at three different neutron energies from 13.5 to 14.8 MeV. The fast neutrons were produced via the H( d, n)He reaction on Pd-300 neutron generator. The natural high-purity PrO powder was used as target material. Induced gamma...

  • Study of near-stability nuclei populated as fission fragments in heavy-ion fusion reactions. Fotiades, N.; Cizewski, J. A.; Nelson, R. O.; Devlin, M.; Krücken, R.; Clark, R. M.; Fallon, P.; Lee, I. Y.; Macchiavelli, A. O.; Becker, J. A.; Younes, W. // AIP Conference Proceedings;10/28/2011, Vol. 1377 Issue 1, p216 

    Examples are presented to illustrate the power of prompt γ-ray spectroscopy of fission fragments from compound nuclei with A∼200 formed in fusion-evaporation reactions in experiments using the Gammasphere Ge-detector array. Complementary methods, such as Coulomb excitation and...

  • New Bound to the Probability of [sup 76]Ge�� Decay to the 0[sup +][sub 1][sup 76]Se Level. Vasil�ev, S. I.; Klimenko, A. A.; Osetrov, S. B.; Smol�nikov, A. A. // JETP Letters;9/25/2000, Vol. 72 Issue 6, p279 

    Measurements were carried out at the underground low-background laboratory of the Baksan Neutrino Observatory using a detection system involving four ultrapure germanium detectors made from enriched [sup 76]Ge. The sensitivity of the experiment to the detection of a [sup 76]Ge double beta decay...

  • Germanium detector sees galactic gamma-ray line.  // Physics Today;Oct78, Vol. 31 Issue 10, p17 

    Reports the discovery of a gamma-ray line in Australia by a balloon carried-germanium detector. Details on the positron annihilation line; Participants in the project; Information on other searches for the line.

  • l-Arginine treatment may prevent tubulointerstitial nephropathy caused by germanium dioxide. Yanagisawa, Hiroyuki; Yamazaki, Nobuyuki; Sato, Gen; Wada, Osamu // Kidney International;Jun2000, Vol. 57 Issue 6, p2275 

    L-Arginine treatment may prevent tubulointerstitial nephropathy caused by germanium dioxide. Background. Long-term oral ingestion of germanium dioxide (GeO2 ) causes progressive renal failure derived from tubulointerstitial nephropathy in humans and animals. The characteristic of GeO2 -induced...

  • Dead-time correction and I[sub O] normalization in germanium solid-state detector systems using... Dent, A.J.; Derbyshire, G.E.; Derst, G.; Farrow, R.C. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2306 

    Presents an abstract of a paper reporting on a study of dead-time correction and I[sub 0] normalization in germanium solid-state detector systems using an incoming count rate monitor. Main factor determining the rate limitation of a photon counting germanium solid-state detector system; Main...

  • Detection characteristics of an ultralow-energy measurable pure-germanium detector in the... Kohagura, J.; Cho, T.; Hirata, M.; Yatsu, K.; Tamano, T.; Ogasawara, T.; Yagishita, A.; Sekitani, T.; Maezawa, H. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2317 

    Investigates the detection characteristics of an ultralow-energy measurable pure-germanium detector in the hundreds-eV photon-energy region. Description of the experimental setup; Output current from each detector; X-ray response for high-energy x rays; Detection-efficiency data.

  • High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors. Callas, J. L.; Mahoney, W. A.; Varnell, L. S.; Wheaton, Wm. A. // Review of Scientific Instruments;Jan1993, Vol. 64 Issue 1, p143 

    Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2° becomes practical by combining position-sensitive germanium detectors having a segment...

  • Size distribution and electroluminescence of self-assembled Ge dots. Vescan, L.; Stoica, T. // Journal of Applied Physics;5/15/2000, Vol. 87 Issue 10, p7275 

    Presents information on a study which examined the electroluminescence and size distribution of p-i-n diode structures with germanium (Ge) dots. How the Ge dots were formed; Experimental details; Results and discussion; Conclusions.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.