Simulation of (n,γ) experiments with the Karlsruhe 4π BaF[sub 2] detector

Reifarth, R.; Heil, M.; Krticˇka, M.; Becˇva´rˇ, F.
July 2000
AIP Conference Proceedings;2000, Vol. 529 Issue 1, p746
Academic Journal
© 2000 American Institute of Physics.


Related Articles

  • The Detector for Advanced Neutron Capture Experiments at LANSCE. Ullmann, J.L.; Reifarth, R.; Haight, R.C.; Hunt, L.; O'Donnell, J.M.; Rundberg, R.S.; Bredeweg, T.A.; Wilhelmy, J.B.; Fowler, M.M.; Vieira, D.J.; Wouters, J.M.; Strottman, D.D.; Kaeppeler, F.; Hiel, M.; Chamberlin, E.P. // AIP Conference Proceedings;2003, Vol. 680 Issue 1, p271 

    The Detector for Advanced Neutron Capture Experiments (DANCE) is a 159-element 4π barium fluoride array designed to study neutron capture on small quantities, 1 mg or less, of radioactive nuclides. It is being built on a 20 m neutron flight path which views the “upper tier” water...

  • n_TOF Experiment: Past, Present And Future. Marrone, S.; Abbondanno, U.; Aerts, G.; Álvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becˇvárˇ, F.; Berthoumieux, E.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Capote, R.; de Albornoz, A. Carnllo; Cennini, P.; Chepel, V. // AIP Conference Proceedings;3/31/2009, Vol. 1109 Issue 1, p78 

    The neutron Time-of-Flight facility at CERN was built to measure the neutron capture and fission cross sections. A short description of the facility, the detectors and the data analysis techniques will be illustrated. A short review of the preliminary results on the fission cross sections is...

  • Neutron spectroscopy with 6LiF bolometers. Gironnet, J.; van den Brandt, B.; Coron, N.; Hautle, P.; Filges, U.; Konter, J. A.; de Marcillac, P.; Ortigoza, Y.; Puimedon, J.; Rolon, T.; Torres, L. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p751 

    A compact and semi-portable neutron detector has been built based on the bolometric technique. Its unique features open new possibilities for the radioprotection survey of fast neutrons at nuclear installations and the investigations of background problems of sensitive neutron scattering...

  • The EXILL campaign. FRANCE, G; BLANC, A; DROUET, F; JENTSCHEL, M; KÖSTER, U; MUTTI, P; RÉGIS, J; SIMPSON, G; SOLDNER, T; STEZOWSKI, O; LEONI, S; URBAN, W; VANCRAYENEST, A // Pramana: Journal of Physics;Sep2015, Vol. 85 Issue 3, p467 

    A combination of germanium detectors was installed at the PF1B neutron guide of the ILL to perform prompt spectroscopy of neutron-rich nuclei produced in the neutron-capture induced-fission of U and Pu. In addition, LaBr detectors from the FATIMA Collaboration were installed to complement with...

  • Two miniaturised TEPCS in a single detector for BNCT microdosimetry. Moro, D.; Colautti, P.; Gualdrini, G.; Masi, M.; Conte, V.; De Nardo, L.; Tornielli, G. // Radiation Protection Dosimetry;Dec2006, Vol. 122 Issue 1-4, p396 

    Microdosimetry with tissue-equivalent proportional counters (TEPC) has proven to be an ideal dosimetry technique for mixed radiation fields as those ones used in boron neutron capture therapy (BNCT). A new counter, composed of two twin cylindrical mini TEPCs inserted in a slim titanium sleeve of...

  • Neutron Transfer Reactions: Surrogates for Neutron Capture for Basic and Applied Nuclear Science. Cizewski, J. A.; Jones, K. L.; Kozub, R. L.; Pain, S. D.; Peters, W. A.; Adekola, A.; Allen, J.; Bardayan, D. W.; Becker, J. A.; Blackmon, J. C.; Chae, K. Y.; Chipps, K. A.; Erikson, L.; Gaddis, A.; Harlin, C.; Hatarik, R.; Howard, J.; Jandel, M.; Johnson, M. S.; Kapler, R. // AIP Conference Proceedings;3/15/2009, Vol. 1099 Issue 1, p724 

    Neutron capture reactions on unstable nuclei are important for both basic and applied nuclear science. A program has been developed at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory to study single-neutron transfer (d,p) reactions with rare isotope beams to provide...

  • A Highly Efficient Neutron Veto Using Boron-Loaded Liquid Scintillator. Wright, A.; Mosteiro, P.; Loer, B.; Calaprice, F. // AIP Conference Proceedings;4/27/2011, Vol. 1338 Issue 1, p44 

    By surrounding a dark matter detector with a layer of boron-loaded liquid scintillator, a highly efficient neutron veto can be produced. In Monte Carlo studies, a one meter thick layer of scintillator has a veto efficiency greater than 99.5% for nuclear recoil events induced by radiogenic...

  • Improved Scintillator Materials for Compact Electron Antineutrino Detectors. Dijkstra, Peter; Wortche, Heinrich J.; Browne, Wesley R. // AIP Conference Proceedings;4/27/2011, Vol. 1338 Issue 1, p221 

    Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and...

  • The Detector for Advanced Neutron Capture Experiments: A 4Ï€ BaF2 Detector for Neutron Capture Measurements at LANSCE. Ullmann, J. L.; Agvaanluvsan, U.; Alpizar, A.; Bond, E. M.; Bredeweg, T. A.; Esch, E.-I.; Folden, C. M.; Greife, U.; Hatarik, R.; Haight, R. C.; Hoffman, D. C.; Hunt, L.; Kronenberg, A.; O'Donnell, J. M.; Reifarth, R.; Rundberg, R. S.; Schwantes, J. M.; Strottman, D. D.; Vieira, D. J.; Wilhelmy, J. B. // AIP Conference Proceedings;2005, Vol. 769 Issue 1, p918 

    The Detector for Advanced Neutron Capture Experiments (DANCE) is a 162-element 4Ï€ BaF2 array designed to make neutron capture cross-section measurements on rare or radioactive targets with masses as little as one milligram. Accurate capture cross sections are needed in many research areas,...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics