TITLE

Position sensitive germanium detectors for the Advanced Compton Telescope

AUTHOR(S)
Kroeger, R. A.; Johnson, W. N.; Kurfess, J. D.; Phlips, B. F.; Luke, P. N.; Momayezi, M.; Warburton, W. K.
PUB. DATE
April 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 510 Issue 1, p794
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The nuclear line region of the gamma ray spectrum remains one of the most challenging and elusive goals of high energy astrophysics. The scientific objectives are well defined, but require well over a factor of 10 increase in sensitivity compared to present day instruments to be achieved. The most promising approach to achieve this sensitivity and a broad range of scientific objectives is offered by an Advanced Compton Telescope (ACT) that would function in the 0.5 to 30 MeV energy range. The ACT builds on the successful COMPTEL instrument on NASA’s Gamma Ray Observatory by substituting modern detectors with over an order of magnitude better energy and spatial resolution. Germanium detectors are a natural choice, as they are available in large volumes, provide the best possible energy resolution, and are capable of fine spatial resolution. These improvements alone provide the required gain in sensitivity. Further optimization and the use of more sophisticated techniques promise even greater improvements. We discuss the current status of the germanium detector technology. New results from the characterization of a crossed strip detector using amorphous-germanium contacts and a demonstration of three-dimensional position resolution are presented. © 2000 American Institute of Physics.
ACCESSION #
6029679

 

Related Articles

  • Optical sensor may help robots feel.  // Machine Design;2/23/95, Vol. 67 Issue 4, p42 

    Examines the potential of a prototype optical position sensor as a more reliable replacement for potentiometers. Application as tactile sensor for robots due to its compactness; Replacement of the light pipes with fiber optic cables to shrink the sensor; Advantage over potentiometers.

  • Electron detection by resistive charge division based position sensitive detectors. Ra¨isa¨nen, J.; Harju, O.; Tjurin, G.; Riihima¨ki, I.; Lindholm, L. // Review of Scientific Instruments;Dec2001, Vol. 72 Issue 12, p4358 

    The use of resistive charge division based solid-state detectors for position sensing of electrons has been studied. The operational conditions having importance for device performance are considered for one- and two-dimensional detectors manufactured by SiTek®. The parameter of main interest...

  • Low noise position sensitive detector for optical probe beam deflection measurements. Spear, Jonathan D.; Russo, Richard E. // Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2481 

    Reports on the design of an optical position sensor that uses discrete photodiodes electrically connected in parallel, with opposing polarities. Restriction of the acceptance angle of the detector; Response of the device to displacements of an optical spot; Measurements by the sensor of the...

  • Position sensitive sensors provide background suppression.  // Environmental Engineering;Mar98, Vol. 11 Issue 1, p35 

    Provides information on the D1 series of triangular photoelectric sensors from Matsushita Automation Controls. Use of a position sensitive device for the sensors; Self-diagnosis function of the sensors.

  • Capacitive sensor for micropositioning in two dimensions Kolb, P. W.; Kolb, P.W.; Decca, R. S.; Decca, R.S.; Drew, H. D.; Drew, H.D. // Review of Scientific Instruments;Jan1998, Vol. 69 Issue 1, p310 

    Develops a capacitive sensor for micropositioning in two dimensions. Principles of the sensing operation; Compatibility with high magnetic field and cryogenic temperature; Effect of electronics used on positioning resolution; Factors limiting the position reproducibility.

  • Radiation position-sensitive detector based on plastic scintillating fibers. Ikhlef, A.; Skowronek, M. // Review of Scientific Instruments;Sep93, Vol. 64 Issue 9, p2566 

    The applicability of plastic scintillation fibers as a radiation position detector is evaluated for low-energy x-ray irradiation. A continuous x-ray generator with a copper anode is used as a source radiating very intense lines: K[sub α2]=8.02 keV, K[sub α1] = 8.04 keV, K[sub β1] = 8.9...

  • Method for fabricating a simple low-cost position-sensitive photodetector. Burns, Michael J. // Review of Scientific Instruments;Mar89, Vol. 60 Issue 3, p327 

    We describe a very simple method for making a low-cost wide-band position-sensitive photodetector (PSD) and preamplifier circuit. The detector is most suitable for experiments where a laser is used to measure the deflection (linear or angular) of some part of the experimental apparatus. The...

  • A temporally resolved position sensing device for autofocusing. Shie, Jin-Shown; Chang, Gow-Dawn // Review of Scientific Instruments;Mar91, Vol. 62 Issue 3, p825 

    A position-sensing method for autofocus purpose is demonstrated, based on the triangular ranging principle applied to a photoconductive Haynes-Shockley device. This method provides a linear variation of the minority-carrier transit time in the sensor with respect to the inverse of the object...

  • Effects of intensity and position modulation on switched electrode electronics beam position monitor systems at Jefferson Lab. Powers, Tom // AIP Conference Proceedings;2000, Vol. 546 Issue 1, p541 

    Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics