ABSTRACT
A beamline for circularly polarized radiation from a Sasaki type elliptical double undulator has been recently commissioned at BESSY-II. The PGM (Plane Grating Monochromator) based beamline works with collimated light and employs only one set of optical elements for steering and monochromatising the two (circularly) polarized, angularly separated, beams. The first commissioning results are presented here to illustrate the capabilities of this undulator-beamline concerning photon flux, photon energy resolution and polarization characteristics. © 2000 American Institute of Physics.
ACCESSION #
6029400

 

Related Articles

  • Perspectives on micropole undulators in synchrotron radiation technology. Tatchyn, Roman; Csonka, Paul; Toor, Arthur // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1796 

    Micropole undulators promise to advance synchrotron radiation (SR) technology in two distinct ways. The first is in the development of economical, low-energy storage rings, or linacs, as soft x-ray sources, and the second is in the opening up of gamma-ray spectral ranges on high-energy storage...

  • Wiggler x-ray beamlines at Synchrotron Radiation Research Center. Tsang, K.-L.; Lee, C.-H.; Jean, Y.-C.; Dann, T.-E.; Chen, J.-R.; D'Amico, K.L.; Oversluizen, T. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1812 

    Describes the design and construction of three x-ray beamlines extracted out from one 25-pole 1.8 T wiggler insertion device at the Synchrotron Radiation Research Center in Taiwan. Design of the front end for the wiggler x-ray beamlines; Features of the A, B, and C beamlines and the photon...

  • Characterization of radiation from a figure-8 undulator by a gas-scattering method. Tanaka, Takashi // Journal of Applied Physics;8/15/2000, Vol. 88 Issue 4, p2101 

    Focuses on the characterization of radiation from a figure-eight undulator by a gas-scattering method. Consistency of the absolute-flux measurements with the calculated values and angular divergence measurements; Effect of altering the vertical observation angle on the polarization plane;...

  • Insertion devices for third-generation light sources (invited). Kitamura, Hideo // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2007 

    Describes what kind of insertion devices should be installed in third-generation light sources. Wide-band characteristics of synchrotron radiation from bending magnets; Undulators for hard x-ray; Undulators for vacuum ultraviolet radiation.

  • X-ray microtomography on beamline X at SSRL. Kinney, J. H.; Johnson, Q. C.; Nichols, M. C.; Bonse, U.; Saroyan, R. A.; Nusshardt, R.; Pahl, R. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2471 

    This article describes a high-resolution three-dimensional CT system which has been tested on the new wiggler beamline X-2 at the Stanford Synchrotron Radiation Laboratory. The present system is a rotate-only design which uses a virtual phase CCD array camera optically coupled to a...

  • Conversion of the SRS to a higher brilliance lattice (invited). Thompson, D. J.; Suller, V. P. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1377 

    The SRS at Daresbury has been upgraded by the addition of quadrupoles which reduce the emittance by a factor of 15. In order to do this without disturbing the beamlines, all 16 straight sections were rebuilt. Additional sextupole and octupole magnets were included, as was additional pumping...

  • Personal-computer-based control system for a 1.8 T hybrid wiggler. Quimby, D.C.; Robinson, K.E.; Jander, D.R. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1949 

    Describes a personal-computer-based control system that was developed for the 1.8 T wiggler to be delivered to the Synchrotron Radiation Research Center in Hsinchu, Taiwan. Major functions of the system; Configuration; Motion control; Operator interface.

  • Dynamical x-ray diffraction from a perfect crystal under grazing incidence conditions. Hashizume, H.; Sakata, O. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2373 

    Synchrotron radiation obtained from the 6-T vertical-wiggler source at the Photon Factory has been used to study dynamical x-ray diffraction in a nearly perfect germanium crystal under total external reflection conditions. A specially designed goniometer has allowed independent control of the...

  • Polarizing undulator with crossed and retarded magnetic fields. Onuki, Hideo; Saito, Norio; Saito, Terubumi; Habu, Mitsuhiro // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1838 

    A prototype of the polarizing undulator with crossed and retarded magnetic fields which was able to produce any kind of elliptically polarized synchrotron radiation from relativistic electrons was designed and constructed. This undulator was installed in a straight section of the electron...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics