TITLE

Uncertainty determination in QXAFS measurements

AUTHOR(S)
Quintana, J. P. G.
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 521 Issue 1, p194
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Measured uncertainties in QEXAFS measurements are determined using an oversampling technique. The output of an ionization chamber is read through a current amplifier using a sampling analog to digital converter. By oversampling the data, uncertainties are determined simultaneously with data collection. © 2000 American Institute of Physics.
ACCESSION #
6029387

 

Related Articles

  • Real-time x-ray diffraction of metastable phases during solidification from the undercooled LuFeO3 melt by two-dimensional detector at 1 kHz. Vijaya Kumar, Malahalli; Kuribayashi, K.; Nagashio, K.; Ishikawa, T.; Okada, J.; Yu, J.; Yoda, S.; Katayama, Y. // Applied Physics Letters;5/7/2012, Vol. 100 Issue 19, p191905 

    In-situ identification of metastable phases formed from the undercooled LuFeO3 melt under controlled oxygen partial pressure Po2 was studied by x-ray diffraction measurements at a synchrotron radiation source. Real-time observation of the formation and growth of individual phases during the...

  • The Use Of Full-Field XRF For Simultaneous Elemental Mapping. Alfeld, M.; Janssens, K.; Sasov, A.; Liu, X.; Kostenko, A.; Rickers-Appel, K.; Falkenberg, G. // AIP Conference Proceedings;4/6/2010, Vol. 1221 Issue 1, p111 

    The characteristics of a Full-Field X-ray Fluorescence (FF-XRF) set-up for element-specific imaging, installed at the HASYLAB synchrotron radiation source, were determined. A lateral resolution of 10 μm and limits of detection in the percentage range were found. Further potential developments...

  • Concentration of neutral oxygen vacancies in buried oxide formed by implantation of oxygen. Seol, Kwang Soo; Futami, Tsuyoshi; Ohki, Yoshimichi // Journal of Applied Physics;2/15/1998, Vol. 83 Issue 4, p2357 

    Provides information on an experiment using synchrotron radiation as a photon source to obtained photoluminescence spectra for buried oxide formed by implantation of oxygen. Methodology used to conduct the experiment; Results of the experiment.

  • Investigation of interface morphology and compostion mixing in CdTe/CdS heterojunction... Soo, Y.L.; Huang, S.; Kao, Y.H.; Compaan, A.D. // Journal of Applied Physics;4/15/1998, Vol. 83 Issue 8, p4173 

    Provides information on an experimental study using synchroton radiation to investigate interface morphology and composition mixing in CdTe/CdS heterojunction photovoltaic materials. Methodology used to conduct the experiment; Information on grazing incidence x-ray scattering (GIXS)...

  • Conceptual design of SPring-8 front ends. Sakurai, Y.; Oura, M.; Sekae, H.; Usui, T.; Kimuri, H.; Oikawa, Y.; Kitamura, H.; Konishi, T.; Shiwaku, H.; Nakamura, A.; Amamoto, H.; Harami, T. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1771 

    Describes the design philosophy and conceptual layout of the front ends of the SPring-8 synchrotron radiation facility under construction in Japan. Arrangements and components of the front ends; Use of graphite filters to cut the low energy part of the synchrotron radiation.

  • Europe open new era in synchrotron research. Butler, Declan // Nature;10/6/1994, Vol. 371 Issue 6497, p469 

    Reports on the opening of the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Third generation synchrotrons which produce fine beams of X-rays at chosen wavelengths; Development of synchrotron radiation since 1947; Comparison with conventional X-rays; Popularity of...

  • Design of an x-ray beamline on a bending magnet at the ESRF for magnetic and high resolution... Paul, D.F.; Cooper, M.J.; Stirling, W.G. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1741 

    Describes the options for the optical design of the UK-CRG beamline that is to be built at the European Synchrotron Radiation Facility in Grenoble, France. Design development; Simple toroid; Paraboloid design; Performance of the optical designs.

  • Insertion devices for third-generation light sources (invited). Kitamura, Hideo // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2007 

    Describes what kind of insertion devices should be installed in third-generation light sources. Wide-band characteristics of synchrotron radiation from bending magnets; Undulators for hard x-ray; Undulators for vacuum ultraviolet radiation.

  • Digital mammography with synchrotron radiation. Arfelli, F.; Bravin, A.; Barbiellini, G.; Cantatore, G.; Castelli, E.; Di Michiel, M.; Poropat, P.; Rosei, R.; Sessa, M.; Vacchi, A.; Palma, L. Dalla; Longo, R.; Bernstorff, S.; Savoia, A.; Tromba, G. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1325 

    Focuses on the synchrotron radiation for medical physics (SYRMEP) beamline, which is under construction at the ELETTRA synchrotron radiation facility in Trieste, Italy. Source of radiation for the beamline; Cross section of the beam impinging on the monochromator crystal; Monochromator; Detector.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics