TITLE

Progress towards top-up mode operations at the Advanced Photon Source

AUTHOR(S)
Emery, L.; Borland, M.
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 521 Issue 1, p409
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The Advanced Photon Source (APS) is a 7-GeV, third-generation synchrotron radiation source. To provide a more stable beam for users, in September 1998 we began commissioning a new operating mode called “top-up.” In this mode, the beam current does not decay but is maintained at a high level using frequent injection, while photon shutters are open and photon beams are delivered to users. The exhaustive analysis for top-up safety will be reviewed as well as the hardware and software required for top-up operation. Operational experience so far includes testing aspects of top-up injection, delivering beam to X-ray users for a few hours with fractional current stability of 0.001, and routinely providing beam to users by refilling the ring to 100 mA every 12 hours with shutters open. Top-up performance issues encountered are short-lived orbit and emittance transients during the injection event, which appear in user experiments as X-ray beam brightness dips. Planned system modifications to reduce these beam transients are described. The main operational issue left for continuous top-up injection will then be sharing the injector system with other operations. © 2000 American Institute of Physics.
ACCESSION #
6029341

 

Related Articles

  • Extraction of infrared radiation from SPring-8. Hara, M.; Be, S. H.; Takeshita, I.; Nanba, T. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1543 

    Extraction of infrared beams from SPring-8 storage ring is investigated. SPring-8 is a third generation insertion device oriented synchrotron radiation source in x-ray region. It is noticeable, however, that a highly powerful radiation source in infrared region can be obtained from the bending...

  • Quality limits for electron rings. Kasuga, Toshio // AIP Conference Proceedings;2001, Vol. 592 Issue 1, p44 

    Longitudinal phase-space issues that limit the performance of electron storage rings, especially synchrotron radiation sources, are discussed. Single-bunch operation, a phenomenon that deteriorates single-bunch purity and measures of purity deterioration are given. The importance of the...

  • Injection, dynamic aperture, and beam instability of a small synchrotron radiation source in the hard-x-ray region. Okuda, S.; Nakanishi, T.; Itoga, K.; Nakata, S.; Yamamoto, S.; Yamada, T.; Iwamoto, M. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1705 

    A small synchrotron radiation source in the hard-x-ray region was conceptually designed and its injection scheme, dynamic aperture, and beam instabilities were studied. Synchrotron radiation with the critical wavelength of 0.1 nm is emitted from a pair of superconducting bending magnets. The...

  • Prospective nonlithographic applications of a synchrotron radiation source for deep-etch lithography. Moser, H. O.; Ehrfeld, W. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2164 

    It is pointed out that the performance of superconducting storage ring synchrotron radiation sources designed for deep-etch lithography like the source KSSQ planned at Karlsruhe is much superior to that of typical thin film lithography sources and comes close to that of first and second...

  • SPEAR 3. Hettel, R. // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p375 

    SSRL has embarked on the SPEAR 3 upgrade project that will replace the present SPEAR storage ring magnet lattice, vacuum chamber, RF system, and ancillary accelerator components in 2002. SPEAR 3 will have an 18 nm-rad emittance, reduced from 160 nm-rad, and will support a 500 mA beam current at...

  • New possibilities and some construction problems of low emittance rings at an energy of 8–10 GeV (invited) (abstract). Kulipanov, G. N. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1406 

    The fields of using a new generation of synchrotron radiation sources storage rings at an energy of 8-10 GeV are discussed. Much attention is paid to the problems whose solution opens the basically new possibilities: generation of pulsed beams of slow high brightness positrons, obtaining of...

  • X-ray supermirrors for BESSY II. Erko, A.; Schafers, F.; Vidal, B.; Yakshin, A.; Pietsch, U.; Mahler, W. // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p4845 

    Studies x-ray multilayer supermirrors for the BESSY-II storage ring. Measurement of the supermirrors with synchrotron radiation; Description of the supermirrors.

  • The Canadian Light Source. Dallin, L. O.; Skopik, D. M.; Hallin, E. L.; Bergstrom, J. C. // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p391 

    The Canadian Light Source (CLS) is a 2.9 GeV synchrotron light facility currently under construction in Saskatoon, Saskatchewan. The design goal was to achieve 3rd generation characteristics in a relatively compact lattice to produce a very economical light source. Full energy injection is...

  • A new gap separation mechanism for APS insertion devices. Trakhtenberg, E. M.; Tcheskidov, V. G.; Den Hartog, P. K.; Deriy, B. N.; Erdmann, M.; Makarov, O. A.; Moog, E. R. // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p363 

    A new gap separation mechanism for use with the standard Advanced Photon Source (APS) 3.3-cm-period undulator magnetic structures has been designed and built, and the first system has been installed in the APS storage ring. The system allows a minimum magnetic gap of 10 mm for use with the APS...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics