TITLE

Direct measurement of the time structure of ultrashort x-ray pulses from a storage ring

AUTHOR(S)
Walton, Donnell T.
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 521 Issue 1, p479
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The pulse timing structure of the positron storage ring at the Advanced Photon Source has been measured. A simple and straightforward detector system was employed to capture and record the x-ray pulses while the storage ring operated in its standard mode of 6+25 triplets. In this mode the most dense x-ray pulse structure was clearly resolved with respect to the inter-pulse spacing and pulse position. The pulse profiles are presented clearly detailing the time structure of the storage ring. © 2000 American Institute of Physics.
ACCESSION #
6029329

 

Related Articles

  • Longitudinal Spin-Transfer in Λ Production at HERMES. Chiang, H.C. // AIP Conference Proceedings;2003, Vol. 675 Issue 1, p543 

    Spin transfer in deep-inelastic Λ electroproduction has been studied with the HERMES detector using the 27.6-GeV polarized positron beam in the HERA storage ring. The longitudinal spin transfer DLL, from the virtual photon to the Λ has been extracted as a function of z, the fraction of...

  • A Plane Parallel Chamber Used as a Stopped Muon Detector for the Active Target of the FAMILON Project. Vorobyev, S. I.; Gordeev, V. A.; Zhdanov, A. A.; Elkin, Yu. V.; Ivochkin, V. G.; Komarov, E. N.; Kosianenko, S. V.; Scheglov, Yu. A.; Scherbakov, G. V. // Instruments & Experimental Techniques;Sep/Oct2005, Vol. 48 Issue 5, p585 

    The performance characteristics of a plane parallel chamber were investigated on beams of slow muons and positrons, as well as on an electron beam from a 106Ru β source. The chamber was filled with CO2 or a gas mixture of Ar (30%) + CO2(70%) at atmospheric pressure. The amplitude spectra of...

  • Synchrotron Radiation Profile Monitor for the HERA Positron Beam. Kube, G.; Fischer, R.; Wittenburg, K. // AIP Conference Proceedings;2004, Vol. 732 Issue 1, p350 

    For the measurement of the positron beam emittance at the e-p storage ring HERA at DESY a monitor is used which is based on the direct imaging of visible synchrotron radiation from a bending magnet. While the resolution of profile measurements by synchrotron radiation is already strictly limited...

  • Latest Results from DVCS at HERMES. Yaschenko, Sergey // AIP Conference Proceedings;3/23/2009, Vol. 1105 Issue 1, p173 

    The HERMES experiment at DESY, Hamburg, collected a rich data set for the analysis of Deeply Virtual Compton Scattering (DVCS) utilizing the HERA polarized electron or positron beams with an energy of 27.6 GeV and longitudinally and transversely polarized or unpolarized gas targets (H, D or...

  • A trap-based pulsed positron beam optimised for positronium laser spectroscopy. Cooper, B. S.; Alonso, A. M.; Deller, A.; Wall, T. E.; Cassidy, D. B. // Review of Scientific Instruments;Oct2015, Vol. 86 Issue 10, p1 

    We describe a pulsed positron beam that is optimised for positronium (Ps) laser-spectroscopy experiments. The system is based on a two-stage Surko-type buffer gas trap that produces 4 ns wide pulses containing up to 5 x 105 positrons at a rate of 0.5-10 Hz. By implanting positrons from the trap...

  • Beam position mis-measurement due to propagating modes. Smith, Stephen R.; Johnson, Ronald G. // AIP Conference Proceedings;2000, Vol. 546 Issue 1, p601 

    In many modern storage rings, position monitors process beam signals at frequencies above cutoff for propagating modes in the beam duct. This is common in beam ducts with antechambers. Propagating modes introduce fields at the position monitor pickups unrelated to beam position at the monitor,...

  • Synchrotron Area X-ray Detectors, Present and Future. Gruner, Sol M. // AIP Conference Proceedings;6/24/2010, Vol. 1234 Issue 1, p69 

    X-ray experiments are very frequently detector limited at today’s storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day...

  • Development and use of a thin-film transmission positron moderator. Lynn, K. G.; Nielsen, B.; Quateman, J. H. // Applied Physics Letters;8/1/1985, Vol. 47 Issue 3, p239 

    A narrow energy beam of slow positrons can be generated by moderating the beta-decay spectrum of a radioactive β[sup +] source. We report here the development and use of the first moderator in which the low-energy positrons are not extracted from the surface facing the β[sup +] emitter but...

  • Variable-energy positron-beam studies of SiO2/Si irradiated by ionizing radiation. Uedono, A.; Tanigawa, S.; Suzuki, K.; Watanabe, K. // Applied Physics Letters;8/8/1988, Vol. 53 Issue 6, p473 

    Variable-energy positron-beam studies have been carried out on Si with a 1.61 μm overlayer of SiO2 irradiated by x ray and γ ray up to the dose of 5×105 R. The Doppler broadening of annihilation photons was found to be strongly influenced by x-ray irradiation, and the effect was...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics