TITLE

The latest developments in undulator beamlines for valence band spectroscopy at SRC

AUTHOR(S)
Bissen, Mark
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 521 Issue 1, p59
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A stigmatic plane grating monochromator (PGM) and a 4-meter normal incidence monochromator (NIM) were recently installed on undulator sources at the Synchrotron Radiation Center (SRC). Details of their design, installation, and performance will be reported. A new pure permanent magnet (PPM) undulator will be installed next year. The design criteria for spectroscopy beamlines utilizing this source as well as two possible monochromator designs, a modified Wadsworth and a varied line spacing (VLS) monochromator, will be discussed. © 2000 American Institute of Physics.
ACCESSION #
6029326

 

Related Articles

  • Efficiency and Resolving Power of Gratings in the Upper keV Range. Heidemann, K. F.; Kleemann, B. H.; Nelles, B. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p659 

    The efficiency of blazed and laminar gratings is calculated by electromagnetic diffraction theory for grazing incidence monochromator and spectrometer configurations at photon energies up to 10 keV. Blaze efficiencies of more than 40% can be achieved at photon energies up to 6 keV. The...

  • Design of a Conical Diffraction Type Plane Holographic Grating Monochromator for Use in the Energy Region of 1–4 keV. Koike, Masato; Namioka, Takeshi // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p865 

    The holographic plane grating with grooves of a radial form and its imaging properties in a converging beam are analyzed. The results are applied to the design of conical diffraction monochromators for the 1–4 keV region, and their expected performances are examined by means of ray...

  • Variable Groove Depth Gratings and their Applications in Soft X-ray Monochromators. Polack, François; Lagarde, Bruno; Idir, Mourad; Cloup, Audrey Liard; Jourdain, Erick // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p639 

    A Variable Groove Depth (VGD) grating is a laminar grating where the depth of the groove profile changes continuously along the grating lines. When illuminated by a narrow beam a few mm wide, they allow to adapt the depth of the groove profile the wavelength in use by simply translating the...

  • On the Spectra Selectivity of Talbot and Lau Effects. Lokshin, G. R.; Uchenov, A. V.; �ntin, M. A.; Belonuchkin, V. E.; Eskin, N. I. // Optics & Spectroscopy;Aug2000, Vol. 89 Issue 2, p312 

    The locations of self-reproduction planes in the Talbot effect and the distance between coherence peaks in the Lau effect are functions of the radiation wavelength. This fact can be used to develop new methods for spectral investigations. Below, we estimate the spectral selectivity of Talbot and...

  • Active diffraction gratings: Development and tests. Bonora, S.; Frassetto, F.; Zanchetta, E.; Della Giustina, G.; Brusatin, G.; Poletto, L. // Review of Scientific Instruments;Dec2012, Vol. 83 Issue 12, p123106 

    We present the realization and characterization of an active spherical diffraction grating with variable radius of curvature to be used in grazing-incidence monochromators. The device consists of a bimorph deformable mirror on the top of which a diffraction grating with laminar profile is...

  • Design of Grazing Incident Monochromator for Saga Synchrotron Light. Kondo, Yuzi; Azuma, Junpei; Takahashi, Kazutoshi; Kamada, Masao; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p627 

    The Varied Line Spacing Plane Grating Monochromator (VLSPGM) was adopted for industry application beamline at Saga-ring. The VLSPGM is consisted of three focusing mirrors and one grating to suppress the higher order and stray light in the wide energy range by changing the deflection angle. The...

  • In-situ Precise Angle Monitoring on Synchrotron Radiation Monochromator by Use of Pencil Beam Interferometer. Qian, Shinan; Takacs, Peter; Qinli Dong; Hulbert, Steve; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p616 

    Monochromator is a very important and precise instrument used in beam lines at synchrotron radiation facilities. We need to know if there is actual thermal distortion on gratings resulting in the degradation of the monochromator resolution. We need to know the characteristics of the grating...

  • A Soft X-Ray (300–1000 eV) Active Grating Monochromator Beamline at NSRRC. Fung, H. S.; Yuh, J. Y.; Huang, L. J.; Tseng, T. C.; Perng, S. Y.; Wang, D. J.; Tsang, K. L.; Chung, S. C. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p563 

    To accommodate the growing number of users in the soft X-ray spectroscopy research at NSRRC, we have developed a modified Dragon-type beamline, namely the active grating monochromator (AGM) beamline. In this beamline, a selected photon beam of 9 mrad radiation fan in the horizontal direction...

  • Synthesis of Planar Reflective Gratings for Silicon Interconnects. Millett, Ronald; Ramsey, Jamie; Bock, Przemek; Nkanta, Julie; Schriemer, Henry; Hall, Trevor J.; Bidnyk, Serge // Advances in Optical Technologies;2008 Special Issue 1, p1 

    The design and simulations of planar reflective gratings for building optical interconnects in silicon-on-insulator (SOI) were studied for a range of silicon core thicknesses of 0.1 to 10 μm. The verticality of the grating facets has been shown to be the main contributing factor to the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library