TITLE

Thermoelectric SQUID method for the detection of segregations

AUTHOR(S)
Hinken, Johann H.; Tavrin, Yury
PUB. DATE
May 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 509 Issue 1, p2085
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Aero engine turbine discs are most critical parts. Material inhomogeneities can cause disc fractures during the flight with fatal air disasters. Nondestructive testing (NDT) of the discs in various machining steps is necessary and performed as well as possible. Conventional NDT methods, however, like eddy current testing and ultrasonic testing have unacceptable limits. For example, subsurface segregations often cannot be detected directly but only indirectly in such cases when cracks already have developed from them. This may be too late. A new NDT method, which we call the Thermoelectric SQUID Method, has been developed. It allows for the detection of metallic inclusions within non-ferromagnetic metallic base material. This paper describes the results of a feasibility study on aero engine turbine discs made from Inconel® 718. These contained segregations that had been detected before by anodic etching. With the Thermoelectric SQUID Method, these segregations were detected again, and further segregations below the surfaces have been found, which had not been detected before. For this new NDT method the disc material is quasi-transparent. The Thermoelectric SQUID Method is also useful to detect distributed and localized inhomogeneities in pure metals like niobium sheets for particle accelerators. © 2000 American Institute of Physics.
ACCESSION #
6029145

 

Related Articles

  • Integrated YBa[sub 2]Cu[sub 3]O[sub 7-x] magnetometer for biomagnetic measurements. Drung, D.; Ludwig, F. // Applied Physics Letters;3/4/1996, Vol. 68 Issue 10, p1421 

    Fabricates direct current superconducting quantum interference device (SQUID) magnetometer using YBa[sub 2]Cu[sub 3]O[sub 7-x] (YBCO)-SrTiO[sub 3]-YBCO multilayer process. Insertion of the SQUID robe in biomagnetic dewar; Observation of biomagnetic measurements for integrated magnetometer;...

  • Transfer function and noise properties of YBa[sub 2]Cu[sub 3]O[sub 7-δ] direct-current superconducting-quantum-interference-device magnetometers with resistively shunted inductances. Kahlmann, F.; Booij, W. E.; Booij, W.E.; Blamire, M. G.; Blamire, M.G.; McBrien, P. F.; McBrien, P.F.; Tarte, E. J.; Tarte, E.J.; Peng, N. H.; Peng, N.H.; Jeynes, C.; Romans, E. J.; Romans, E.J.; Pegrum, C. M.; Pegrum, C.M. // Applied Physics Letters;7/24/2000, Vol. 77 Issue 4 

    Studies the transfer function and noise properties of direct-current superconducting-quantum-interference-device (SQUID) magnetometers with resistively shunted inductances. Maximum voltage modulation depth and calculated values based on the theoretical predictions by Enpuku, et. al.; White...

  • Low 1/f flux noise in sputtered YBa2Cu3O7-x bicrystal dc-superconducting quantum interference... Sarnelli, E.; Camerlingo, C.; Russo, M.; Torrioli, G.; Castellano, M. G. // Journal of Applied Physics;10/15/1997, Vol. 82 Issue 8, p3922 

    Analyzes the YBa2Cu3O7-x bicrystal dc-superconducting quantum interference devices (SQUID) and single layer magnetometers working at 77 K. Different geometrical configurations of SQUID characteristic parameters; Comparison between experimental H values and calculated ones by using Eq; Behavior...

  • High performance dc SQUID magnetometers with single layer YBa[sub 2]Cu[sub 3]O[sub 7-x] flux.... Koelle, D.; Miklich, A.H. // Applied Physics Letters;12/27/1993, Vol. 63 Issue 26, p3630 

    Details the fabrication of direct current (dc) superconducting quantum interference device (SQUID) magnetometers with single film YBa[sub 2]Cu[sub 3]O[sub 7-x] flux transformers. Attachment of the transformer to a loop directly coupled to a dc SQUID; Values of the lowest magnetic field noise...

  • Axial high-temperature superconducting-quantum-interference-device gradiometer composed of magnetometers with a monolithic feedback and compensation coil. Yokosawa, Koichi; Oyama, Hiroshi; Kuriki, Shinya; Suzuki, Daisuke; Tsukada, Keiji // Applied Physics Letters;4/30/2001, Vol. 78 Issue 18, p2745 

    A first-order axial gradiometer has been constructed using two high-critical-temperature superconducting-quantum-interference-device magnetometers having a double-pickup loop configuration on bicrystal substrates. The magnetometer, which had a slot-type structure but no weak links on the pickup...

  • Low noise YBa[sub 2]Cu[sub 3]O[sub 7-x] SQUID magnetometers operated with additional positive.... Drung, D.; Dantsker, E.; Ludwig, F.; Koch, H.; Kleiner, R.; Clarke, John; Krey, S.; Reimer, D.; David, B.; Doessel, O. // Applied Physics Letters;3/25/1996, Vol. 68 Issue 13, p1856 

    Presents a low noise YBa[sub 2]Cu[sub 3]O[sub 7-x] superconducting quantum interference devices magnetometers operated with additional positive feedback. Use of flux locked loop; Obtainment of high quality magnetocardiograms.

  • Unlocked detection of SQUID signals: Theory and design. Dubuc, C.; Benhida, K.; Bloyet, D. // Review of Scientific Instruments;May91, Vol. 62 Issue 5, p1333 

    We describe the principle and implementation of a new unlocked processing of SQUID signals. A digital interpolation is achieved by using the periodicity of the voltage-flux transfer characteristic. The method is analyzed and the choice of the main parameters is discussed. A practical...

  • A miniature magnetometer based on the superconducting quantum interference device with direct... Polushkin, V.; Wallis, M.; Glowacka, D.; Matthews, A.; Lumley, John M. // Review of Scientific Instruments;Mar97, Vol. 68 Issue 3, p1461 

    Develops a novel miniature superconducting quantum interference device magnetometer with direct readout electronics. High flux-to-voltage transfer factor achieved without additional positive feedback; Flux resolution corresponding to a magnetic moment sensitivity; Study of the dynamic...

  • Four layer monolithic integrated high T[sub c] dc SQUID magnetometer. Hilgenkamp, J.W.M.; Brons, G.C.S. // Applied Physics Letters;6/20/1994, Vol. 64 Issue 25, p3497 

    Fabricates and characterizes a YBa[sub 2]Cu[sub 3]O[sub 7-x] based monolithic integrated direct current superconducting quantum interference device magnetometers. Composition of the devices; Operation of the first realization up to 73 Kelvin; Observation of a maximum voltage modulation of 32...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics