TITLE

Computing LISA far field phase patterns

AUTHOR(S)
Waluschka, Eugene
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 523 Issue 1, p401
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
© 2000 American Institute of Physics.
ACCESSION #
6028815

 

Related Articles

  • Measurement of position and orientation of optical elements in interferometric gravity wave... Heitmann, Henrich; Drezen, Christine // Review of Scientific Instruments;Aug1997, Vol. 68 Issue 8, p3197 

    Describes the measurement of position and orientation of optical elements in interferometric gravity wave detectors. Description of the VIRGO interferometer; Fine and coarse measurement scheme; Imaging system; Calculation of the mass coordinates.

  • Searching for gravity waves with interferometers. Schechter, Bruce // Physics Today;Feb86, Vol. 39 Issue 2, p17 

    Examines the efficacy of laser interferometers in detecting gravity waves from astrophysical sources. Description of laser interferometers; Sources of gravitational radiation; Factors affecting the sensitivity of an interferometers.

  • High-stability laser to detect gravitational waves. Roux, Roland // Laser Focus World;Dec94, Vol. 30 Issue 12, p18 

    Focuses on the use of a Michelson interferometer to detect gravitational waves in France. Features of the interferometer; Size; Requirements in the detection of low-amplitude gravitational waves.

  • Digitally controlled interferometer prototype for gravitational wave detection. Barone, Fabrizio; Calloni, Enrico; Di Fiore, Luciano; Grado, Aniello; Milano, Leopoldo; Russo, Guido // Review of Scientific Instruments;Dec1996, Vol. 67 Issue 12, p4353 

    Describes the architecture of the suspended Michelson interferometer prototype for gravitational wave detection which is operational in Napoli. Digital implementation of the control system, monitoring system, data acquisition system and archiving system; Automatic control of interferometers for...

  • An injection locked Nd:YAG laser for the glasgow 10m interferometric gravitational wave detector. Clubley, D. A.; Skeldon, K. D.; Newton, G. P. // AIP Conference Proceedings;2000, Vol. 523 Issue 1, p391 

    We report on recent work to develop a new injection-locked Nd:YAG laser for the Glasgow 10m prototype gravitational wave interferometer. We have stabilised the master laser frequency to a rigid reference cavity and measured the residual frequency noise using one of the arm cavities of the 10-m...

  • Interferometer configurations—an overview. Strain, Kenneth A. // AIP Conference Proceedings;2000, Vol. 523 Issue 1, p173 

    The configuration of an interferometer, i.e., the disposition of the optical components which compose it, is chosen to provide sensitivity to a wide range of signals. Two basic configurations—Michelson and Sagnac interferometers—are described, as well as a range of advanced...

  • The status of LIGO. Coles, Mark W. // AIP Conference Proceedings;2000, Vol. 523 Issue 1, p101 

    Construction activities at the LIGO Observatories near Hanford, Washington and Livingston, Louisiana are complete. Installation of detector components and initial commissioning of detector sub-systems is now under way. The scope of the overall project is reviewed. The current status of the...

  • Pentagonal two-loop ring interferometer. Agachev, A. R.; Balakin, A. B.; Buınov, G. N.; Buchinskaya, S. L.; Daishev, R. A.; Kisun’ko, G. V.; Komissaruk, V. A.; Mavrin, S. V.; Murzakhanov, Z. G.; Rafikov, R. A.; Skochilov, A. F.; Cheredilin, V. A.; Chugunov, Yu. P. // Technical Physics;May98, Vol. 43 Issue 5, p591 

    Results of work on the assembly and adjustment of an original pentagonal, two-loop interferometer are reported; the interferometer is a passive version of a compact laser gravitational wave detector. It is shown that the correlative automatic noise-compensation system developed for the project...

  • Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection. Losurdo, G.; Calamai, G.; Cuoco, E.; Fabbroni, L.; Guidi, G.; Mazzoni, M.; Stanga, R.; Vetrano, F.; Holloway, L.; Passuello, D.; Ballardin, G.; Braccini, S.; Bradaschia, C.; Cavalieri, R.; Cecchi, R.; Cella, G.; Dattilo, V.; Di Virgilio, A.; Fidecaro, F.; Frasconi, F. // Review of Scientific Instruments;Sep2001, Vol. 72 Issue 9, p3533 

    In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called the superattenuator, is fully effective at frequencies above 4 Hz. But the residual motion of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics