TITLE

Tests on a prototype spherical detector

AUTHOR(S)
Astone, P.; Bassan, M.; Bonifazi, P.; Carelli, P.; Coccia, E.; D’Antonio, S.; Fafone, V.; Frossati, G.; Marini, A.; Mauceli, E.; Merkowitz, S.; Minenkov, Y.; Modena, I.; Moleti, A.; Modestino, G.; Pallottino, G. V.; Papa, M.; Pizzella, G.; Raffone, G.; Ronga, F.
PUB. DATE
June 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 523 Issue 1, p430
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We report on our progresses in the design and construction of the suspension system for a 3 kHz spherical detector. The plan for our SFERA project is to build a small cryogenic spherical detector by the year 2001. © 2000 American Institute of Physics.
ACCESSION #
6028801

 

Related Articles

  • Dark matter search in the EDELWEISS experiment using a 320 g ionization-heat Ge-detector. Navick, X.-F.; Benoit, A.; Berge´, L.; Broniatowski, A.; Chambon, B.; Chapellier, M.; Chardin, G.; Charvin, P.; De Je´sus, M.; Drain, D.; Dumoulin, L.; Gascon, J.; Gerbier, G.; Goldbach, C.; Goyot, M.; Gros, M.; Hadjout, J-P.; Herve´, S.; Juillard, A.; de Lesquen, A. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p489 

    The EDELWEISS collaboration has performed a direct search for WIMPs using a 320g ionization-heat Ge-cryogenic detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils events are observed in the fiducial volume in the 30-200 keV energy range...

  • Development of cryogenic detectors for GNO. Lachenmaier, T.; Feilitzsch, F. v.; Jagemann, T.; Jochum, J.; Lanfranchi, J.-C.; Potzel, W.; Ru¨dig, A.; Schnagl, J.; Stark, M.; Wulandari, H. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p465 

    The neutrino capture reaction [sup 71]Ga(v[sub e],e[sup -])[sup 71] Ge and the reverse EC-decay is used by GNO to monitor the flux of solar neutrinos in a routinely operating neutrino observatory. Low temperature detectors (LTDs) offer a better performance concerning efficiency, energy...

  • Cryogenic sources for low temperature detector characterization. Leblanc, E.; Tsoupko-Sitnikov, V.; Leblanc, J. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p395 

    Low temperature detector studies require non-contaminating cryogenic sources covering a wide range of energies and activity levels. For detector calibration in case of low background measurements we developed very low activity sources of well-known emission flux. In order to study energy...

  • Gas phase cryogenic photoacoustic detector. Keffer, Charles E.; Conner, Charles P.; Smith, William H. // Review of Scientific Instruments;Nov85, Vol. 56 Issue 11, p2161 

    A variable temperature cryogenic photoacoustic detector has been developed for making spectroscopic measurements on gas phase molecules. Temperatures in the range of 77-300 K are obtained with this device.

  • Void fraction measurement in two-phase helium flow with electron energy attenuation detector. Augyrond, L.; Ageron, P.; Blumenfeld, H.; Bredy, Ph.; Lugol, J.-C. // AIP Conference Proceedings;2002, Vol. 613 Issue 1, p1667 

    A void fraction measurement system has been developed using a small electron source (Sr90) associated with a commercial semiconductor detector. This system has been designed for measurements in two-phase helium flow near saturated conditions at atmospheric pressure (4.2 K). Both elements of the...

  • Ultra-light flexible temperature and liquid level sensing probe for cryogenic propellant mass gauging systems. Haberbusch, Mark S. // AIP Conference Proceedings;2002, Vol. 613 Issue 1, p1292 

    The Cryo-Trackerâ„¢, a patent pending, ultra-light, flexible sensing probe for measuring fluid temperature gradients and liquid level has been created for launch vehicle mass gauging systems for cryogenic propellant tanks. The unique one-piece, polyimide mechanically-flexible sensing probe...

  • Identification of near surface events in massive bolometers. Mirabolfathi, N.; Marnieros, S.; Berge´, L.; Dumoulin, L. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p517 

    We present a method allowing identification of near surface events in bulk cryogenic detector. It is based on amplitude effects in the athermal signal given by Anderson insulator thermometric layers. Applied to Ge detectors, the method may allow the rejection of near electrode events with...

  • Fabrication of bridge-type microcalorimeter arrays with Ti-Au transition-edge-sensors. Ukibe, M.; Kimura, T.; Nagaoka, T.; Pressler, H.; Ohkubo, M. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p207 

    The present stage of cryogenic detector development is focused on fabrication of arrays. Arrays of superconducting-transition-edge-sensor (TES) microcalorimeters have generally been fabricated on SiN[sub x] membranes. In conventional membrane structures fabricated by backside etching, it is...

  • In-situ and post irradiation behavior of cryogenic temperature sensors under fast neutron fluence. Filippov, Y. P.; Golikov, V. V.; Kulagin, E. N.; Miklayev, V. M.; Sukhanova, A. K. // AIP Conference Proceedings;2002, Vol. 613 Issue 1, p1700 

    The report continues our investigations of the thermometers which can be operated under conditions combining high radiation environment and cryogenic temperatures. To clarify temperature shifts due to fast neutron irradiation up to 10[sup 16] n/cm², additional platinum, carbon-glass and TVO...