TITLE

One-dimensional space resolving flat-field holographic grating soft x-ray framing camera spectrograph for laser plasma diagnostics

AUTHOR(S)
Xiong, Gang; Hu, Zhimin; Li, Hang; Zhao, Yang; Shang, Wanli; Zhu, Tuo; Wei, Minxi; Yang, Guohong; Zhang, Jiyan; Yang, Jiamin
PUB. DATE
April 2011
SOURCE
Review of Scientific Instruments;Apr2011, Vol. 82 Issue 4, p043109
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 Ã…. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5Ã… in has been observed clearly.
ACCESSION #
60283512

 

Related Articles

  • A simple high-resolution on-line x-ray imaging crystal spectrograph for laser-plasma interaction studies. Arora, V.; Kumbhare, S. R.; Kumbhare, S.R.; Naik, P. A.; Naik, P.A.; Gupta, P. D.; Gupta, P.D. // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    A simple, high-resolution x-ray imaging crystal spectrograph is described for on-line measurements and analysis of x-ray emission from laser-produced plasmas in the wavelength range of ∼5-12 Å. The spectrograph uses a planar TAP crystal for dispersion and a phosphor-coated optical fiber...

  • SPARTUVIX: A time-resolved XUV transmission grating spectrograph for x-ray laser research. Bourgade, J. L.; Combis, P.; Louis-Jacquet, M.; Le Breton, J. P.; de Mascureau, J.; Naccache, D.; Sauneuf, R.; Thiell, G.; Keane, C.; MacGowan, B.; Matthews, D. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1840 

    A transmission grating streaked spectrograph (SPARTUVIX) has been developed at the Centre d'Etudes de Limeil-Valenton for measuring the temporal evolution of soft-x-ray spectra in laserproduced plasmas. In this article the ideas behind the instrument are described as well as a description of the...

  • Spectral measurements from laser-produced plasma in OMEGA. Burkhalter, P. G.; Newman, D. A.; Rosen, D. L.; Hudson, K.; Richardson, M.; Audebert, P. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p2171 

    Curved- and flat-diffraction crystal spectrographs were developed to collect x-ray spectra from high-atomic-number elements (cadmium-rare earths) in the 5-17-Ã… region. The plasma source was generated by the 24-beam, frequency-tripled light of the OMEGA laser system. The spectral patterns...

  • Experimental study of neutron induced background noise on gated x-ray framing cameras. Izumi, N.; Hagmann, C.; Stone, G.; Hey, D.; Glenn, S.; Conder, A.; Teruya, A.; Sorce, C.; Tommasini, R.; Stoeffl, W.; Springer, P.; Landen, O. L.; Herrmann, H. W.; Kyrala, G. A.; Bahukutumbi, R.; Glebov, V. Y.; Sangster, T. C.; Eckart, M.; Mackinnon, A. J.; Koch, J. A. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E515 

    A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce...

  • Framed, 16-image, Kirkpatrick–Baez microscope for laser–plasma x-ray emission. Marshall, F. J.; Oertel, J. A.; Walsh, P. J. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4045 

    A framed, 16-image, Kirkpatrick–Baez (KB)-type x-ray microscope has been designed for use in imaging laser–plasma x-ray emission. The reflecting elements are 16 pairs of concave mirrors arranged to reflect and focus x rays emanating from a laser-produced plasma. The resolution of...

  • Progress on the development of a single line of sight x-ray framing camera. Bradley, D. K.; Holder, J. P.; Damian, C. M.; Piston, K. W.; Bell, P. M.; Dymoke-Bradshaw, A. K. L.; Hares, J. D. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4054 

    High-speed microstrip microchannel plate (MCP) x-ray framing cameras are a well established diagnostic for laser plasma experiments. Each frame acquired with these devices requires a separate image, and with most reasonable x-ray optics, a separate line of sight, causing potential parallax...

  • X-ray imaging with grazing-incidence microscopes developed for the LIL program. Rosch, R.; Boutin, J. Y.; le Breton, J. P.; Gontier, D.; Jadaud, J. P.; Reverdin, C.; Soullié, G.; Lidove, G.; Maroni, R. // Review of Scientific Instruments;Mar2007, Vol. 78 Issue 3, p033704 

    This article describes x-ray imaging with grazing-incidence microscopes, developed for the experimental program carried out on the Ligne d’Intégration Laser (LIL) facility [J. P. Le Breton et al., Inertial Fusion Sciences and Applications 2001 (Elsevier, Paris, 2002), pp....

  • Time-resolved x-ray line intensities for diagnostics of laser-produced plasmas (abstract). Kauffman, R. L.; Medecki, H.; Lee, R. W.; Whitten, B. L.; Estabrook, K. G.; Drake, R. P.; Turner, R. E.; Letts, S. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p844 

    We have developed a streaked crystal spectrograph for time-resolving x-ray lines from laserproduced plasmas. The spectrograph combines an ellipsoidally curved crystal and x-ray streak camera to optimize spectral coverage and resolution, even though the instrument is located a meter from the...

  • Opacity of Krypton X-ray lines in high-temperature plasma implosion. Zhen, Zhiqiang; He, Jian // Modern Physics Letters B;11/30/2019, Vol. 33 Issue 33, pN.PAG 

    For accurate electron temperature and density diagnostics in laser high-temperature plasma implosion, opacity of Krypton (Kr) helium- β and Balmer- α lines are discussed, and ratio of escape factor of the two X-rays are calculated, both for Gaussian and Holtzmarkian profiles. Finally, the...