TITLE

Extracorporeal life support systems: alternative vs. conventional circuits

AUTHOR(S)
Khan, Sameer; Vasavada, Rahul; Feng Qiu; Kunselman, Allan; Ündar, Akif
PUB. DATE
May 2011
SOURCE
Perfusion;May2011, Vol. 26 Issue 3, p191
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Emerging technologies and practices for pediatric and neonatal extracorporeal life support (ECLS) are promising. This experiment sought to compare the Medtronic 0800 silicon rubber membrane oxygenator to the Quadrox-iD Pediatric oxygenator in the conventional roller pump circuit, as well as comparing the conventional circuit to an alternative circuit. Three circuits were set up in the experiment. Two conventional roller pump circuits were used to compare the two oxygenators and an alternative circuit consisting of the Quadrox-iD Pediatric oxygenator and Maquet Rotaflow centrifugal pump system was used to identify differences between circuits. All three circuits were primed with Lactated Ringers’ solution and human blood, with an hematocrit of 40%. Testing occurred at flow rates of 250, 500, and 750 ml/ min at 37°C for mean arterial line pressures of 60, 80, and 100 mmHg. The results of the experiment showed lower pressure drops and greater retention of total hemodynamic energy (THE) across the Quadrox-iD Pediatric oxygenator compared to the Medtronic 0800 oxygenator. Furthermore, the centrifugal pump used in the alternative circuit showed no back flow at flow rates as low as 250 ml/min while, on the other hand, rpm levels were kept below 2200 for flow rates as high as 750 ml/min. Findings support the usage of the Quadrox-iD Pediatric oxygenator in a circuit utilizing the Maquet Rotaflow centrifugal pump system due to lower pressure drops and greater percentage of THE retained across the circuit. Additional advantages of the alternative circuit include rapid set-up time, easy transport, lower priming volumes, and no gravity-dependent venous drainage system so that it can be situated in close proximity to and at the level of the patient.
ACCESSION #
60094576

 

Related Articles

  • Evaluation of two pediatric polymethyl pentene membrane oxygenators with pulsatile and non-pulsatile perfusion. Feng Qiu; Khan, Sameer; Talor, Jonathan; Kunselman, Allan; Ündar, Akif // Perfusion;May2011, Vol. 26 Issue 3, p229 

    Objectives: This experiment sought to compare two polymethyl pentene (PMP) hollow-fiber membrane oxygenators: the Medos HILITE 2400 LT and the Maquet Quadrox-iD Pediatric in terms of transmembrane pressure gradients and hemodynamic energy preservation under both pulsatile and non-pulsatile...

  • An investigational study of minimum rotational pump speed to avoid retrograde flow in three centrifugal blood pumps in a pediatric extracorporeal life support model. Clark, Joseph B; Yulong Guan; McCoach, Robert; Kunselman, Allen R; Myers, John L; Ündar, Akif // Perfusion;May2011, Vol. 26 Issue 3, p185 

    During extracorporeal life support with centrifugal blood pumps, retrograde pump flow may occur when the pump revolutions decrease below a critical value determined by the circuit resistance and the characteristics of the pump. We created a laboratory model to evaluate the occurrence of...

  • Hemodynamic evaluation of arterial and venous cannulae performance in a simulated neonatal extracorporeal life support circuit. Qiu, F.; Clark, J.B.; Kunselman, A.R.; Ündar, A.; Myers, J.L. // Perfusion;Jul2011, Vol. 26 Issue 4, p276 

    Objective: To construct an ideal extracorporeal life support (ECLS) circuit in terms of hemodynamic performance, each component of the circuit should be evaluated. Most cannulae manufacturers evaluate their products using water as the priming solution. We conducted this study to evaluate the...

  • Efficacy and safety of strategies to preserve stable extracorporeal life support flow during simulated hypovolemia. Simons, AP; Lindelauf, AAMA; Ganushchak, YM; Maessen, JG; Weerwind, PW // Perfusion;Jan2014, Vol. 29 Issue 1, p18 

    The article presents an in vitro study aimed at measuring the efficacy and safety of several pump control modalities combined with a volume buffer capacity (VBC) on centrifugal pump-based extracorporeal life support (ELS) stability and gaseous microemboli (GME) load during conditions of...

  • Centrifugal pump inlet pressure site affects measurement. Augustin, Simon; Horton, Alison; Butt, Warwick; Bennett, Martin; Horton, Stephen // Perfusion;Sep2010, Vol. 25 Issue 5, p313 

    During extracorporeal life support (ECLS), blood is exposed to a myriad of unphysiological factors that can affect outcome. One aspect of this is the sub-atmospheric pressure generated by the ECLS pump and imparted to blood elements along the pump inlet line. This pressure can be measured on the...

  • Total artificial heart in the pediatric patient with biventricular heart failure. Park, SS; Sanders, DB; Smith, BP; Ryan, J; Plasencia, J; Osborn, MB; Wellnitz, CM; Southard, RN; Pierce, CN; Arabia, FA; Lane, J; Frakes, D; Velez, DA; Pophal, SG; Nigro, JJ // Perfusion;Jan2014, Vol. 29 Issue 1, p82 

    Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with...

  • DEVELOPMENT OF A METABOLIC EQUATION FOR THE NuSTEP RECUMBENT STEPPER IN OLDER ADULTS. DALLECK, LANCE C.; BORRESEN, ERICA C.; PARKER, AMANDA L.; ABEL, KELLY M.; HABERMANN, LAURA A.; MCLAUGHLIN, SARAH J.; TISCHENDORF, JESSICA S. // Perceptual & Motor Skills;Feb2011, Vol. 112 Issue 1, p183 

    The purpose of this study was to develop an accurate metabolic equation for estimating steady-state oxygen consumption (VO2) during submaximal NuStep exercise. Adults (N = 40; M age = 64.0 yr., SD = 6.5; M height = 170.1 cm, SD = 9.1 ; M weight = 85.7 kg, SD = 19.9) performed two randomized...

  • Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter. Salavitabar, Arash; Feng Qiu; Kunselman, Allen; Ündar, Akif // Perfusion;Nov2010, Vol. 25 Issue 6, p409 

    Cardiopulmonary bypass (CPB) can be a potential cause of morbidity in patients for several reasons, including significantly higher gaseous microemboli (GME) formation than extracorporeal life support (ECLS) and physiological circulation, diverted blood flow from the patient via an open purge...

  • The practice of withholding and withdrawing life-support measures among patients with cancer in Jordan. Khater, Wejdan A.; Akhu-Zaheya, Laila M.; Abu Alhijaa, Eyad H.; Abdulelah, Hazem A.; EL-Otti, Sanaa N. // International Journal of Palliative Nursing;Sep2011, Vol. 17 Issue 9, p440 

    In Jordan, an Arabic Islamic country, decisions around withholding and/or withdrawing life support measures still present both moral and professional dilemmas. The purpose of this study was to explore the use of such measures among patients with cancer in Jordan. The medical records of 436...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics