TITLE

Cannula design reduces particulate and gaseous emboli during cardiopulmonary bypass for coronary revascularization

AUTHOR(S)
Lata, Adrian L; Hammon, John W; Deal, Dwight D; Stump, David A; Kincaid, Edward H; Kon, Neal D
PUB. DATE
May 2011
SOURCE
Perfusion;May2011, Vol. 26 Issue 3, p239
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: The incidence of neurocognitive deficits after coronary bypass surgery remains problematic, with atheroembolism being one of the major causes. External manipulation of aorta and the “sandblasting” effect of the high-velocity perfusion jet can cause dislodgement of atheromatous debris.Description: A new arterial cannula features a tip configuration that diffuses the flow through multiple outlets, providing reduced velocity and shear with one central and three diverted flow streams.Evaluation: Between March 2007 and July 2008 twenty patients having isolated coronary artery bypass operations were instrumented with an Embolus Detection and Classification transducer. These data were compared to 43 patients from a previous study using similar techniques except for a standard open-tip arterial cannula. Total embolic counts were markedly lower in the new cannula group (20±25 vs 174±378) as were both gaseous (11±15 vs 95±211) and particulate counts (9±11 vs 80±194).Conclusions: The select 3D cannula design reduces the sandblasting effect of the perfusion jet and, also, may direct emboli from the heart and cardiopulmonary bypass equipment away from the cerebral circulation.
ACCESSION #
60094575

 

Related Articles

  • Commentary on: Can minimized cardiopulmonary bypass systems be safer? Weerwind, P // Perfusion;May2012, Vol. 27 Issue 3, p185 

    The article presents a commentary expressing the views of P. Weerwind about his paper presentation at the 32nd Annual Seminar of the American Academy of Cardiovascular Perfusion. He mentions the use of Better Bladderâ„¢, a compliance chamber, into miniaturized circuit for procedures such as...

  • Can minimized cardiopulmonary bypass systems be safer? Ganushchak, YM; Ševerdija, EE; Simons, AP; van Garsse, L; Weerwind, PW // Perfusion;May2012, Vol. 27 Issue 3, p176 

    Although a growing body of evidence indicates superiority of minimized cardiopulmonary bypass (mCPB) systems over conventional CPB systems, limited venous return can result in severe fluctuations of venous line pressure which can result in gaseous emboli. In this study, we investigated the...

  • Handling ability of gaseous microemboli of two pediatric arterial filters in a simulated CPB model. Strother, A; Wang, S; Kunselman, Ar; Ündar, A // Perfusion;May2013, Vol. 28 Issue 3, p244 

    The article reports a study which compared the Sorin KIDS D131 and the Terumo Capiox AF02 pediatric arterial filters in a simulated cardiopulmonary bypass (CPB) procedure to determine which filter is the better for clinical use. The results revealed that both filters were similar in their...

  • The impact of balanced hydroxylethyl starch cardiopulmonary bypass priming solution on the fibrin part of clot formation: ex vivo rotation thromboelastometry. Appelman, Marly H; van Barneveld, Lerau J M; Romijn, Johannes W A; Vonk, Alexander B A; Boer, Christa // Perfusion;May2011, Vol. 26 Issue 3, p175 

    Introduction: Balanced colloidal priming solutions are supposed to further minimize the effects of cardiopulmonary bypass (CPB) on haemostasis as compared to gelatin-based preparations. This exploratory study investigated whether clot formation, in particular the fibrin part of the clot, is less...

  • Editorial. Rubens, Fraser D. // Perfusion;May2011, Vol. 26 Issue 3, p173 

    The author strongly recommends the perfusion community to embrace new technologies, in particular the use of thromboelastography (TEG) in direct transfusion practice, to address the ever-changing environment of cardiovascular intervention. He references two articles in the same issue pertaining...

  • Active or passive bio-coating: does it matters in extracorporeal circulation? Jacobs, S; De Somer, F; Vandenplas, G; Van Belleghem, Y; Taeymans, Y; Van Nooten, G // Perfusion;Nov2011, Vol. 26 Issue 6, p496 

    Background: Two types of surface coating for cardiopulmonary bypass (CPB) are used: bioactive (heparin, nitric oxide) and biopassive (albumin, polyethyleneoxide (PEO), phosphorylcholine). When haemocompatible coatings are combined with the separation of pleuro-pericardial aspiration, attenuation...

  • Comparison of the effects of pulsatile cardiopulmonary bypass, non-pulsatile cardiopulmonary bypass and off-pump coronary artery bypass grafting on the respiratory system and serum carbonyl. Bayram, H; Erer, D; Iriz, E; Zor, M Hakan; Gulbahar, O; Ozdogan, Me // Perfusion;Sep2012, Vol. 27 Issue 5, p378 

    The article reports a study investigating the effects of off-pump coronary artery bypass grafting (CABG), pulsatile cardiopulmonary bypass (CPB), and non-pulsatile CPB techniques on oxidative stress and the respiratory system. The results revealed that off-pump CABG had less negative effects on...

  • Comparison of the effects of pulsatile cardiopulmonary bypass, non-pulsatile cardiopulmonary bypass and off-pump coronary artery bypass grafting on the inflammatory response and S-100beta protein. Bayram, H; Erer, D; Iriz, E; Zor, MH; Gulbahar, O; Ozdogan, ME // Perfusion;Jan2012, Vol. 27 Issue 1, p56 

    Background: We aimed to investigate the effects of off-pump coronary artery bypass grafting, pulsatile cardiopulmonary bypass, and non-pulsatile cardiopulmonary bypass techniques on the inflammatory response and the central nervous system in the current study.Methods: A total of 32 patients who...

  • Reply to Letter. Sohn, N.; Marcoux, J.; Mycyk, T.; Krahn, J.; Meng, Q. H. // Perfusion;Nov2010, Vol. 25 Issue 6, p429 

    A response by N. Sohn and colleagues to a letter to the editor on their article "The impact of different biocompatible coated cardiopulmonary bypass circuits on inflammatory response and oxidative stress," in the 2009 issue is presented.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics