TITLE

Corrected High--Frame Rate Anchored Ultrasound With Software Alignment

AUTHOR(S)
Miller, Amanda L.; Finch, Kenneth B.
PUB. DATE
April 2011
SOURCE
Journal of Speech, Language & Hearing Research;Apr2011, Vol. 54 Issue 2, p471
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To improve lingual ultrasound imaging with the Corrected High Frame Rate Anchored Ultrasound with Software Alignment (CHAUSA; Miller, 2008) method. Method: A production study of the IsiXhosa alveolar click is presented.Articulatory-to-acoustic alignment is demonstrated using a Tri-Modal 3-ms pulse generator. Images from 2 simultaneous data collection paths, using dominant ultrasound technology and the CHAUSA method, are compared. The probe stabilization and head movement correction paradigm is demonstrated. Results: The CHAUSA method increases the frame rate from the standard National Television System Committee (NTSC) video rate (29.97) to the ultrasound internal machine rate—in this case, 124 frames per second (fps)—by using Digital Imaging and Communications in Medicine (DICOM; National Electrical Manufacturers Association, 2008) data transfer. DICOM avoids spatiotemporal inaccuracies introduced by dominant ultrasound export techniques. The data display alignment of the acoustic and articulatory signals to the correct high-frame rate (FR) frame (±4 ms at 124 fps). Conclusions: CHAUSA produces high-FR, high-spatial-quality ultrasound images, which are head corrected to 1 mm. The method reveals tongue dorsum retraction during the posterior release of the alveolar click and tongue tip recoil following the anterior release of the alveolar click, both of which were previously undetectable. CHAUSA visualizes most of the tongue in studies of dynamic consonants with a major reduction in field problems, opening up important areas of speech research.
ACCESSION #
59858947

 

Related Articles

  • STUDIO PRELIMINARE DI UN METODO ALTERNATIVO PER LA MISURAZIONE DELLE CURVE SCOLIOTICHE SU RADIOGRAFIE DIGITALI. Romano, Michele; Rossi, Gianluca // Scienza Riabilitativa;2014, Vol. 16 Issue 2, p11 

    Background: Over the past few years, the increasing use of digital x-rays has modified the traditional methods for the assessment of the magnitude of a scoliosis curve. A preliminary study has been performed to determine whether a measuring tool (scoliometer), normally used for other purposes,...

  • Contrast Improvement in Sub- and Ultraharmonic Ultrasound Contrast Imaging by Combining Several Hammerstein Models. Sbeity, Fatima; Ménigot, Sébastien; Charara, Jamal; Girault, Jean-Marc // International Journal of Biomedical Imaging;2013, p1 

    Sub- and ultraharmonic (SUH) ultrasound contrast imaging is an alternative modality to the second harmonic imaging, since, in specific conditions it could produce high quality echographic images. This modality enables the contrast enhancement of echographic images by using SUH present in the...

  • Dual-pass Feature Extraction on Human Vessel Images. Hernandez, W.; Grimm, S.; Andriantsimiavona, R. // Journal of Digital Imaging;Jun2014, Vol. 27 Issue 3, p351 

    We present a novel algorithm for the extraction of cavity features on images of human vessels. Fat deposits in the inner wall of such structure introduce artifacts, and regions in the images captured invalidating the usual assumption of an elliptical model which makes the process of extracting...

  • Telemis unveils its latest imaging software solution.  // Medical Device Daily;10/21/2013, Vol. 17 Issue 203, p6 

    The article previews the Telemis-Medical Picture Archiving and Communications System (PACS) software version 4.5 from Telemis.

  • Merging medical imagery with CAD. Voegele, Jim // Machine Design;5/10/2012, Vol. 84 Issue 7, p72 

    The article reviews the digital imaging and communications in medicine (Dicom) image-processing program called Slicer, an open-source software package for visualization and medical-image computing.

  • NewTom increases resolution for large field of view images.  // Australasian Dental Practice;Jul/Aug2011, Vol. 22 Issue 4, p138 

    The article discusses the new features of the NewTom VGi Cone Beam Scanner announced by Inline Medical and Dental, a company that specialises in advanced technology. The new collimation allows the NewTom VGi to capture high resolution images along with large volume functionality in a single...

  • Planmeca adds cephalometric analysis.  // Australasian Dental Practice;Jul/Aug2012, Vol. 23 Issue 4, p214 

    The article offers brief information on the Cephaiometric Analysis module to theRomexis imaging software from Henry Schein Halas.

  • Research on Interpolation Methods in Medical Image Processing. Pan, Mei-sen; Yang, Xiao-li; Tang, Jing-tian // Journal of Medical Systems;Apr2012, Vol. 36 Issue 2, p777 

    Image interpolation is widely used for the field of medical image processing. In this paper, interpolation methods are divided into three groups: filter interpolation, ordinary interpolation and general partial volume interpolation. Some commonly-used filter methods for image interpolation are...

  • Fast and Analytical EAP Approximation from a 4th-Order Tensor. Ghosh, Aurobrata; Deriche, Rachid // International Journal of Biomedical Imaging;2012, p1 

    Generalized diffusion tensor imaging (GDTI) was developed to model complex apparent diffusivity coefficient (ADC) using higher-order tensors (HOTs) and to overcome the inherent single-peak shortcoming of DTI. However, the geometry of a complex ADC profile does not correspond to the underlying...

Share