Multiple projection DEXA scanner for precision bone and muscle loss measurements and analysis during prolonged spaceflight

Charles, H. K.; Beck, T. J.; Feldmesser, H. S.; Magee, T. C.; Spisz, T. S.; Pisacane, V. L.
January 2000
AIP Conference Proceedings;2000, Vol. 504 Issue 1, p300
Academic Journal
Bone structural information derived from DEXA data is shown to be relevant in explaining BMD loss versus strength-related observations in both aging populations and individuals exposed to microgravity for prolonged periods. Commercial DEXA instruments are limited (and not optimized) to make these critical structural measurements. Progress on the development of a multiple projection DEXA scanner system for making precision bone and muscle loss measurements and their resultant implications on bone strength and fracture risk is described. © 2000 American Institute of Physics.


Related Articles

  • Ready To Roll. dornheim, Michael A. // Aviation Week & Space Technology;2/9/2004, Vol. 160 Issue 6, p33 

    The Mars Exploration Rover Spirit appears to have recovered from its memory breakdown last week and planned to celebrate by brushing dust off a rock for better measurements of its surface, the first such cleaning on Mars. The remaining 32 MB of flash contains both copies of the flight software....

  • GRBs detected with the MAXI mission on the International Space Station. Tomida, H. // AIP Conference Proceedings;10/16/2010, Vol. 1279 Issue 1, p442 

    Monitor of Al-sky X-ray Image (MAXI) is a mission on the International Space Station. MAXI started its observation from Aug 2009. So far, MAXI detected five GRBs and five candidates of XRF in the 10 month observation, which shows the high capabilty of MAXI for the GRB observations.

  • A suborbital payload for soft X-ray spectroscopy of extended sources. Oakley, Phillip; McEntaffer, Randall; Cash, Webster // Experimental Astronomy;Aug2011, Vol. 31 Issue 1, p23 

    We present a suborbital rocket payload capable of performing soft X-ray spectroscopy on extended sources. The payload can reach resolutions of ∼100 (λ/ Δλ) over sources as large as 3.25° in diameter in the 17-107 Å bandpass. This permits analysis of the overall energy...

  • Microanalysis by monochromatic microprobe x-ray fluorescence -physical basis, properties, ... Chen, Z.W.; Wittry, D.B. // Journal of Applied Physics;7/15/1998, Vol. 84 Issue 2, p1064 

    Presents an microanalysis on the physical basis, properties of monochromatic microprobe x-ray fluorescene (MMXRF). Discussion on the experimental parameters of MMXRF; Characterization of the mica diffractor; Description of the diffraction and properties of the mica diffractor and the...

  • The X-ray source populations of the magellanic clouds. Haberl, F. // AIP Conference Proceedings;2001, Vol. 599 Issue 1, p449 

    ROSAT performed about 250 PSPC observations pointed towards the Magellanic Clouds (MCs). A systematic analysis of the data yielded catalogues with more than 750 X-ray sources in the LMC and about 520 in the SMC region. Cross-correlations with catalogues from various other wavelength bands and...

  • X-rays with the Midas touch. Franklin, Carl // New Scientist;7/17/93, Vol. 139 Issue 1882, p21 

    Reports on KX Technology's Goldstream analyser which can accurately detect gold in a ton of ore. Measurement of solid and dissolved gold; On-stream analyser; X-ray fluorescence spectrometry.

  • Microchannel-plate intensified crystal spectrometer for use in soft x-ray spectroscopy. Hailey, C. J.; Rockett, P.; Eckart, M.; Burkhalter, P. G. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1553 

    A Bragg crystal spectrometer, utilizing a microchannel plate coupled to optical film as the detection medium, has been constructed for use in soft x-ray spectroscopy. The sensitivity of this intensified gated camera to x-rays has been compared directly with standard x-ray film using a calibrated...

  • Two-channel, elliptical analyzer spectrograph for absolute, time-resolving time-integrating spectrometry of pulsed x-ray sources in the 100–10 000-eV region. Henke, B. L.; Jaanimagi, P. A. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1537 

    A new spectrographic system has been developed and calibrated in this laboratory for the absolute spectrometry of high-intensity pulsed x-ray sources in the 100–10 000-eV region. This spectral region is analyzed with fixed elliptically curved crystals and molecular or...

  • X-ray fluorescence analysis of lead in bone Landrigan, Philip J.; Todd, Andrew C. // Environmental Health Perspectives;Nov1993, Vol. 101 Issue 6, p494 

    No abstract available.


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library