TITLE

Determination of the temperature of bremsstrahlung photon generated by ultraintense laser using various thickness attenuators

AUTHOR(S)
Hasegawa, Shuichi; Takashima, Ryuta; Todoriki, Masaru; Kikkawa, Satoshi; Soda, Keita; Takano, Kei; Oishi, Yuji; Nayuki, Takuya; Fujii, Takashi; Nemoto, Koshichi
PUB. DATE
March 2011
SOURCE
Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033301
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We evaluate the simplified method using the Lambert-Beer law to measure the temperature of bremsstrahlung photon generated by an ultraintense laser. Analytical values are compared to the results of the Monte Carlo calculation of GEANT4 and they agreed very well on the condition of the appropriate distance between the attenuator and the detector. We performed the experiment to measure the temperature of bremsstrahlung x-ray emitted from a metal target irradiated by a Ti:sapphire laser with 76 mJ, 72 fs, 2.2 × 1018 W/cm2. For a Cu target of 30 μm thick, the photon temperature was reasonably determined to be 0.18 MeV, which is in good agreement with previous studies.
ACCESSION #
59744563

 

Related Articles

  • Monte Carlo method used to determine scatter fractions for estimating secondary gamma-ray and X-ray photon dose equivalent rates. Bourgois, L.; Comte, N. // Radioprotection (Cambridge University Press);2014, Vol. 49 Issue 2, p107 

    The Monte Carlo MCNPX code is used to calculate the scatter fraction, making it possible to assess the scattered dose equivalent rate. Two materials are considered for the phantom: water and steel. The calculations are performed by considering beams of monoenergetic photons (in the range 10 keV...

  • Electron and photon spread contributions to the radiological penumbra for small monoenergetic x-ray beam (≤2 MeV). Pignol, Jean-Philippe; Keller, Brian M. // Journal of Applied Physics;May2009, Vol. 105 Issue 10, p102011 

    Our team has previously published that submegavoltage photons could significantly improve the radiological penumbra for small size radiation fields. The present work uses Monte Carlo simulation to evaluate the contributions of secondary electrons and photon scatter to the penumbra region for...

  • SIMULACIÓN DE LA DISTRIBUCIÓN ESPECTRAL DE RAYOS -X EN MAMOGRAFÍA POR EL MÉTODO DE MONTE CARLO. Moncada, L.; Puerta, A.; Morales, L. // Revista Colombiana de Física;2006, Vol. 38 Issue 1, p329 

    Considering that x-rays emitted in a mammography system are of low energy, it was assumed, herein, that starting from the half-value layer the behavior of the attenuation coefficient as a function of energy has a slow variation being able to approach a constant coefficient. With this...

  • Monte Carlo Simulation of Photoneutron Dose in Radiotherapy Room as A Function of Gantry Angles. KARA, Ü.; MESBAHI, A.; AKKURT, I. // Acta Physica Polonica, A.;Aug2015, Vol. 128 Issue 2B, pB-378 

    Using bremsstrahlung photon is one of the principal means to treat cancer. Bremsstrahlung photons are created in medical LINAC and the interaction of bremsstrahlung photon with the heavy nuclei that constitute the linac head shielding is the main process of neutron production inside the...

  • DOSE BUILD UP CORRECTION FOR RADIATION MONITORS IN HIGH-ENERGY BREMSSTRAHLUNG PHOTON RADIATION FIELDS. Nair, Haridas G.; Nayak, M. K.; Dev, Vipin; Thakkar, K. K.; Sarkar, P. K.; Sharma, D. N. // Radiation Protection Dosimetry;2006, Vol. 118 Issue 3, p233 

    Conventional radiation monitors have been found to underestimate the personal dose equivalent in the high-energy bremsstrahlung photon radiation fields encountered near electron storage rings. Depth-dose measurements in a water phantom were carried out with a radiation survey meter in the...

  • The energy dispersive x-ray detector: A quantitative model. Joy, David C. // Review of Scientific Instruments;Sep85, Vol. 56 Issue 9, p1772 

    When a Si(Li) solid-state energy dispersive detector is used to collect x-ray photons with energies below 2 keV the characteristic peaks in the spectrum show significant deviations from the ideal Gaussian shape observed for higher energy photons. This effect is due to incomplete collection of...

  • Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX. Hocine, Nora; Donadille, Laurent; Huet, Christelle; Itié, Christian; Clairand, Isabelle // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p231 

    This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses Hp (0.07) and Hp(10) using X-ray photon...

  • Next-to-leading logarithms and the PHOTOS Monte Carlo. Golonka, P.; Wa̧s, Z. // European Physical Journal C -- Particles & Fields;Mar2007, Vol. 50 Issue 1, p53 

    The PHOTOS Monte Carlo program is often used for the simulation of experimental, selection-sensitive, QED radiative corrections in decays of Z bosons and other heavy resonances and particles. The present paper will be devoted to those parts of the next-to-leading order corrections for leptonic Z...

  • Evidence for an excess of soft photons in hadronic decays of Z0. Abdallah, J.; Abreu, P.; Adam, W.; Adzic, P.; Albrecht, T.; Alderweireld, T.; Alemany-Fernandez, R.; Allmendinger, T.; Allport, P.P.; Amaldi, U.; Amapane, N.; Amato, S.; Anashkin, E.; Andreazza, A.; Andringa, S.; Anjos, N.; Antilogus, P.; Apel, W-D.; Arnoud, Y.; Ask, S. // European Physical Journal C -- Particles & Fields;Aug2006, Vol. 47 Issue 2, p273 

    Soft photons inside hadronic jets converted in front of the DELPHI main tracker (TPC) in events of qq̄ disintegrations of the Z0 were studied in the kinematic range 0.2

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics