TITLE

A high-sensitivity angle and energy dipersive multichannel electron momentum spectrometer with 2Ï€ angle range

AUTHOR(S)
Tian, QiGuo; Wang, KeDong; Shan, Xu; Chen, XiangJun
PUB. DATE
March 2011
SOURCE
Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033110
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A high-sensitivity angle and energy dispersive multichannel electron momentum spectrometer with simultaneous detection in 2π angle range is presented. A newly designed double half wedge and strip anode position-sensitive detector is employed to collect the ionized and scattered electrons passing through a 90° sector, 2π spherical electrostatic analyzer over azimuthal angle range of about 150° for each. Experimental results on argon are presented to exhibit the performance of the spectrometer.
ACCESSION #
59744483

 

Related Articles

  • A Liquid-Argon Ionization Detector for the Study of Double β Decay. Ashitkov, V. D.; Barabash, A. S.; Belogurov, S. G.; Carugno, G.; Konovalov, S. I.; Massera, F.; Puglierin, G.; Saakyan, R. R.; Stekhanov, V. N.; Umatov, V. I. // Instruments & Experimental Techniques;Mar/Apr2003, Vol. 46 Issue 2, p153 

    A multisection liquid-argon ionization detector has been developed by the DBA collaboration to study double β decay of 100Mo. The experiment has been carried out in the Gran Sasso underground laboratory in Italy. The detector design and main characteristics are described. The limits on the...

  • Development and test in liquid argon of the light readout system for the ArDM experiment. Boccone, V. // AIP Conference Proceedings;12/17/2009, Vol. 1182 Issue 1, p280 

    ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon (LAr) underground detector. The project relies on the read out of the VUV...

  • Calibration of a multilayer semiconductor spectrometer using α sources. Gurov, Yu.; Gusev, K.; Karpukhin, V.; Lapushkin, S.; Morokhov, P.; Sandukovsky, V.; Yurkowski, J. // Instruments & Experimental Techniques;Sep2006, Vol. 49 Issue 5, p624 

    A method for calibrating a multilayer spectrometer using α particles is presented. This spectrometer is composed of successive semiconductor Si(Li) detectors and is used for precision detection of long-range charged particles (p, d, and t) with energies of ∼100 MeV. The factors affecting...

  • A velocity map imaging detector with an integrated gas injection system. Ghafur, O.; Siu, W.; Johnsson, P.; Kling, M. F.; Drescher, M.; Vrakking, M. J. J. // Review of Scientific Instruments;Mar2009, Vol. 80 Issue 3, p033110 

    We present the design of a velocity map imaging spectrometer where the target gas is injected from a capillary that is integrated in the repeller plate of the ion optics assembly that drives electrons/ions formed by ionization or dissociation to a two-dimensional detector. The geometry of this...

  • Novel technique for the extraction of ionization profiles from spatial density measurements. Deegan, C. M.; Markham, C. E.; Turner, M.; Vender, D. // Review of Scientific Instruments;Dec2001, Vol. 72 Issue 12, p4362 

    A method has been devised to extract the two-dimensional ionization profiles from spatially resolved ion density measurements made in a capacitively coupled argon rf plasma. This technique is valid if the production process is ionization and the loss process is ambipolar diffusion. As this...

  • Ionization of Argon n=2 (Ar[sup +9] to Ar[sup +16]) by a “relativistic” laser field. Walker, Barry C.; Chowdury, Enam A.; Toth, C.; Wilson, K. R.; Barty, C. P. J. // AIP Conference Proceedings;2000, Vol. 525 Issue 1, p667 

    The high field photoionization cross sections for the (n=2) shell of argon were measured with pulsed 800 nm radiation (27±5 fs duration) at an intensity of 1.5×10[sup 19] W/cm[sup 2]±1×10[sup 19] W/cm[sup 2]. The pondermotive energy for an electron at these field intensities is...

  • Direct observation of the steric effect in Penning ionization reaction of Ar[sup *]+CHCl[sub 3]→CHCl[sub 2][sup +]+Cl+e[sup -]+Ar. Yamato, Masanori; Okada, Seiki; Wei-Keh Wu, Victor; Ohoyama, Hiroshi; Kasai, Toshio // Journal of Chemical Physics;10/22/2000, Vol. 113 Issue 16 

    Steric effect in the Penning ionization reaction of Ar[sup *]([sup 3]P[sub 2,0])+CHCl[sub 3]→Ar+CHCl[sub 2][sup +]+Cl+e[sup -] was directly observed at an average collision energy of 0.13 eV using the oriented CHCl[sub 3] molecular beam. The product CHCl[sub 2][sup +] ions are measured...

  • Double ionization of a two-electron model atom in a single-cycle laser pulse. Do¨rr, Martin // AIP Conference Proceedings;2000, Vol. 525 Issue 1, p176 

    We present theoretical results from the solution of a widely used model atom containing two interacting electrons in one dimension bound to a soft-Coulomb potential and ionized by an intense, short laser pulse. A half-cycle pulse leads to strong single but no double ionization (down to a...

  • The performance of the MICE muon beam line. Rayner, Mark Alastair // AIP Conference Proceedings;10/6/2011, Vol. 1382 Issue 1, p193 

    The Muon Ionization Cooling Experiment is one lattice cell of a cooling channel suitable for conditioning the muon beam at the front end of a Neutrino Factory or Muon Collider. The beam line designed to transport muons into MICE has been installed, and data was collected in 2010. In this paper...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics