TITLE

Magnetohydrodynamic interference with the edge pedestal motional Stark effect diagnostic on DIII-D

AUTHOR(S)
King, J. D.; Makowski, M. A.; Holcomb, C. T.; Allen, S. L.; Hill, D. N.; La Haye, R. J.; Turco, F.; Petty, C. C.; Van Zeeland, M. A.; Rhodes, T. L.; Meyer, W. H.; Geer, R.; Morse, E. C.
PUB. DATE
March 2011
SOURCE
Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033515
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Accurate measurement of internal magnetic field direction using motional Stark effect (MSE) polarimetry in the edge pedestal is desired for nearly all tokamak scenario work. A newly installed 500 kHz 32-channel digitizer on the MSE diagnostic of DIII-D allows full spectral information of the polarimeter signal to be recovered for the first time. Fourier analysis of this data has revealed magnetohydrodynamic (MHD) fluctuations in the plasma edge pedestal at ρ >= 0.92. By correlating edge localized mode fluctuations seen on lock-in amplifier outputs with MSE spectrograms, it has been shown that edge pedestal tearing mode fluctuations cause interference with MSE second harmonic instrument frequencies. This interference results in unrecoverable errors in the real-time polarization angle measurement that are more than an order of magnitude larger than typical polarimeter uncertainties. These errors can cause as much as a 38% difference in local q. By using a redundant measure of the linear polarization found at the fourth harmonic photo-elastic modulator (PEM) frequency, MHD interference can be avoided. However, because of poorer signal-to-noise the fourth harmonic signal computed polarization angle shows no improvement over the MHD polluted second harmonics. MHD interference could be avoided in future edge pedestal tokamak polarimeters by utilizing PEMs with higher fundamental frequencies and a greater separation between their frequencies.
ACCESSION #
59744465

 

Related Articles

  • Equilibrium reconstructions of reversed-shear discharges based on motional Stark effect measurements Batha, S. H.; Levinton, F. M.; Wieland, R. M.; Hirshman, S. P. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p392 

    Details how free-boundary equilibrium reconstructions of the temporal evolution of tokamak discharges can be made using internal magnetic field measurements taken in tokamak discharges with a motional Stark effect polarimeter. Boundary positioning algorithm; Variable tension splines;...

  • Polarimetry of motional Stark effect and determination of current profiles in DIII-D (invited). Wróblewski, D.; Lao, L. L. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5140 

    The motional electric field E=v × B, where v is the velocity and B is the tokamak magnetic field, produces a strong Stark effect in spectral lines emitted by hydrogenic neutral beams. The tilt angle of the magnetic field line, a quantity related directly to the distribution of the plasma...

  • The motional Stark effect diagnostic on TEXTOR-94: First measurements. Soetens, T.; Jaspers, R.; Desoppere, E. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p890 

    Describes the development of a diagnostic to measure the motional Stark effect (MSE) on TEXTOR-94 limiter tokamak. Source of the motional Stark effect; Components of the MSE diagnostic; Proportionality of the toroidal magnetic field to the major radius of the observation volume.

  • Equilibrium reconstruction of the safety factor profile in tokamaks from motional Stark effect data. Hirshman, S.P.; Lee, D.K.; Levinton, F.M.; Batha, S.H.; Okabayashi, M.; Wieland, R.M. // Physics of Plasmas;Jul94, Vol. 1 Issue 7, p2277 

    Discusses the use of the motional Stark effect diagnostic to obtain accurate measurements of the internal magnetic pitch angle in finite-pressure tokamaks. Resolution of the coupled nonlinear equations describing both the magnetohydrodynamic equilibrium and the safety factor profile.

  • Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited). Pablant, N. A.; Burrell, K. H.; Groebner, R. J.; Holcomb, C. T.; Kaplan, D. H. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D729 

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line...

  • Available information in 2D motional Stark effect imaging. Creese, Mathew; Howard, John // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D722 

    Recent advances in imaging techniques have allowed the extension of the standard polarimetric 1D motional Stark effect (MSE) diagnostic to 2D imaging of the internal magnetic field of fusion devices [J. Howard, Plasma Phys. Controlled Fusion 50, 125003 (2008)]. This development is met with the...

  • Internal magnetic and electrostatic fluctuation measurements of magnetohydrodynamic modes in the Texas Experimental Tokamak (TEXT). Simcic, V. J.; Crowley, T. P.; Schoch, P. M.; Aydemir, A. Y.; Yang, X. Z.; Connor, K. A.; Hickok, R. L.; Wootton, A. J.; McCool, S. C. // Physics of Fluids B: Plasma Physics;May93, Vol. 5 Issue 5, p1576 

    A heavy ion-beam probe has been used to make the first internal measurements of magnetic fluctuations in a hot tokamak. The magnetic vector potential fluctuation, A[lowercase_phi_synonym]s, is measured during magnetohydrodynamic (MHD) activity and is in reasonable agreement with the prediction...

  • Far-infrared polarimetry diagnostic for measurement of internal magnetic field dynamics and fluctuations in the C-MOD Tokamak (invited). Bergerson, W. F.; Xu, P.; Irby, J. H.; Brower, D. L.; Ding, W. X.; Marmar, E. S. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10E316 

    A laser-based (2.55 THz) mulitchord polarimeter is now operational on Alcator C-Mod and is used to make measurements of the internal magnetic field structure as well as plasma fluctuations. The polarimeter is designed to measure the Faraday effect for high-field (up to 8.3 T) and high-density...

  • Towards the Detection of Magnetohydrodynamics Instabilities in a Fusion Reactor. Sozzi, C.; Alessi, E.; Figini, L.; Galperti, G.; Lazzaro, E.; Marchetto, C.; Mosconi, M.; Nowak, S. // AIP Conference Proceedings;2014, Vol. 1612, p35 

    Various active control strategies of the Neoclassical tearing modes are being studied in present tokamaks using established detection techniques which exploit the measurements of the fluctuations of the magnetic field and of the electron temperature. The extrapolation of such techniques to the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics