TITLE

Failure Mode Classification for Tumor Endoprostheses: Retrospective Review of Five Institutions and a Literature Review

AUTHOR(S)
Henderson, Eric R.; Groundland, John S.; Pala, Elisa; Dennis, Jeremy A.; Wooten, Rebecca; Cheong, David; Windhager, Reinhard; Kotz, Rainer I.; Mercuri, Mario; Funovics, Philipp T.; Hornicek, Francis J.; Thomas Temple, H.; Ruggieri, Pietro; Douglas Letson, G.
PUB. DATE
March 2011
SOURCE
Journal of Bone & Joint Surgery, American Volume;3/2/2011, Vol. 93-A Issue 5, p418
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Massive endoprostheses provide orthopaedic oncologists with many reconstructive options after tumor resection, although failure rates are high. Because the number of these procedures is limited, failure of these devices has not been studied or classified adequately. This investigation is a multicenter review of the use of segmental endoprostheses with a focus on the modes, frequency, and timing of failure. Methods: Retrospective reviews of the operative databases of five institutions identified 2174 skeletally mature patients who received a large endoprosthesis for tumor resection. Patients who had failure of the endoprosthesis were identified, and the etiology and timing of failure were noted. Similar failures were tabulated and classified on the basis of the risk of amputation and urgency of treatment. Statistical analysis was performed to identify dependent relationships among mode of failure, anatomic location, and failure timing. A literature review was performed, and similar analyses were done for these data. Results: Five hundred and thirty-four failures were identified. Five modes of failure were identified and classified: softtissue failures (Type 1), aseptic loosening (Type 2), structural failures (Type 3), infection (Type 4), and tumor progression (Type 5). The most common mode of failure in this series was infection; in the literature, it was aseptic loosening. Statistical dependence was found between anatomic location and mode of failure and between mode of failure and time to failure. Significant differences were found in the incidence of failure mode Types 1, 2, 3, and 4 when polyaxial and uniaxial joints were compared. Significant dependence was also found between failure mode and anatomic location in the literature data. Conclusions: There are five primary modes of endoprosthetic failure, and their relative incidences are significantly different and dependent on anatomic location. Mode of failure and time to failure also show a significant dependence. Because of these relationships, cumulative reporting of segmental failures should be avoided because anatomy-specific trends will be missed. Endoprosthetic design improvements should address failure modes specific to the anatomic location. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
59248679

 

Related Articles

  • Complications of the Angelchik Antireflux Prosthesis. Benjamin, Stanley B.; Kerr, Robert; Cohen, David; Motaparthy, V.; Castell, Donald O. // Annals of Internal Medicine;Apr84, Vol. 100 Issue 4, p570 

    Presents a study which examined complications of the Angelchik antireflux prosthesis. History of the development of Angelchik antireflux prosthesis; Overview of the clinical characteristics of the patients involved in the study; Symptoms of the adverse effect of the prosthesis.

  • Multiple sclerosis and bilateral dislocations of total knee replacements: a case report. Dawson-Bowling, S.; Tavakkolizadeh, A.; Cottam, H.; Butler-Manuel, P. // Knee Surgery, Sports Traumatology, Arthroscopy;Feb2008, Vol. 16 Issue 2, p148 

    We report on a 67-year-old lady with multiple sclerosis (MS) who underwent bilateral total knee replacements using a fixed bearing posterior cruciate retaining prosthesis. Having initially achieved a satisfactory result, she developed recurrent dislocations of both knees necessitating bilateral...

  • Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: a prospective comparative study. Rosenberg, Nahum; Neumann, Lars; Modi, Amit; Mersich, Istvan J.; Wallace, Angus W. // BMC Musculoskeletal Disorders;2007, Vol. 8, p76 

    Background: The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular® shoulder prosthesis taking into consideration the causes of the initial implant's failure. We investigated the impact of changes in the design of...

  • Custom prosthetic replacement for distal radial tumours. Natarajan, Mayil; Chandra Bose, Jagadesh; Viswanath, J.; Balasubramanian, Navin; Sameer, Mohamed // International Orthopaedics;Aug2009, Vol. 33 Issue 4, p1081 

    We analysed the results of 24 cases of aggressive benign and malignant tumours of the distal radius treated by resection and prosthetic replacement between 1995 and 2006. Patient ages ranged from 18 to 74 years, averaging 33 years; 18 were males. Recurrent giant cell tumour was the most common...

  • Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model. Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias // European Radiology;Oct2011, Vol. 21 Issue 10, p2103 

    Objectives: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design....

  • A Survey on the Prevalence of Pseudotumors with Metal-on-Metal Hip Resurfacing in Canadian Academic Centers. Beaulé, Paul E. // Journal of Bone & Joint Surgery, American Volume;5/4/2011 Supplement, Vol. 93-A, p118 

    Background: Metal-on-metal bearings for hip arthroplasty have been in clinical use for over twenty years with excellent clinical results reported worldwide. A small percentage (<1%) of patients have developed an inflammatory response, and a more severe inflammatory response termed pseudotumor...

  • Revision Distal Femoral Arthroplasty With the Compress(®) Prosthesis Has a Low Rate of Mechanical Failure at 10 Years. Zimel, Melissa; Farfalli, German; Zindman, Alexandra; Riedel, Elyn; Morris, Carol; Boland, Patrick; Healey, John; Zimel, Melissa N; Farfalli, German L; Zindman, Alexandra M; Riedel, Elyn R; Morris, Carol D; Boland, Patrick J; Healey, John H // Clinical Orthopaedics & Related Research;Feb2016, Vol. 474 Issue 2, p528 

    Background: Patients with failed distal femoral megaprostheses often have bone loss that limits reconstructive options and contributes to the high failure rate of revision surgery. The Compress(®) Compliant Pre-stress (CPS) implant can reconstruct the femur even when there is...

  • A Rationale for Retrievability of Fixed, Implant-supported Prostheses: A Complication-based Analysis. Ley, John // Journal of Oral Implantology;2007, Vol. 33 Issue 4, p239 

    A review of the article "A Rationale for Retrievability of Fixed, Implant-Supported Prostheses: A Complication-Based Analysis," which appeared in a previous issue of "International Journal Prosthodontics" is presented. The article presents a rationale for screw-retained prostheses resulting from...

  • Cutaneous and Systemic Hypersensitivity Reactions to Metallic Implants. Basko-Plluska, Juliana L.; Thyssen, Jacob P.; Schalock, Peter C. // Dermatitis (Decker Publishing);Mar/Apr2011, Vol. 22 Issue 2, p65 

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics