TITLE

Compensation of temperature effects in quartz crystal microbalance measurements

AUTHOR(S)
Rahtu, Antti; Ritala, Mikko
PUB. DATE
January 2002
SOURCE
Applied Physics Letters;1/21/2002, Vol. 80 Issue 3, p521
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Quartz crystal microbalance (QCM) is a very powerful method for in situ monitoring of thin film growth processes. However, especially at high temperatures, QCM is very sensitive to already minor temperature changes during the measurement. Here, a method for compensating the temperature effects on the QCM is introduced. In this method, the baseline drift during the growth is calculated using a function obtained by fitting the signal measured before and after the growth. The present method is compared with the earlier published reference crystal method where two closely spaced quartz crystals are used, one being protected against film growth and thus serving as a reference crystal for compensating the temperature effects on the measurement crystal. Both methods were tested with TiO[sub 2] and Al[sub 2]O[sub 3] atomic layer deposition processes and the temperature effect was successfully compensated. The differences between these methods are discussed.© 2002 American Institute of Physics.
ACCESSION #
5884212

 

Related Articles

  • Quartz crystal microbalance thin-film dissolution rate monitor. Hinsberg, William D.; Kanazawa, Kay K. // Review of Scientific Instruments;Mar89, Vol. 60 Issue 3, p489 

    We describe the details of construction and operation of an instrument useful for the characterization of dissolution kinetics of thin films. This device, based on a quartz crystal microbalance operating in contact with a liquid, avoids the limitations associated with the use of optical,...

  • Quartz microbalance device for transfer into ultrahigh vacuum systems. Stavale, F.; Niehus, H.; Achete, C. A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p105102 

    An uncomplicated quartz microbalance device has been developed which is transferable into ultrahigh vacuum (UHV) systems. The device is extremely useful for flux calibration of different kinds of material evaporators. Mounted on a commercial specimen holder, the device allows fast quartz...

  • Using a quartz crystal microbalance to probe formation of Xe hydrate in thin ice films. Chan, J.; Forrest, J. A.; Torrie, B. H. // Journal of Applied Physics;9/1/2004, Vol. 96 Issue 5, p2980 

    We have demonstrated the ability of the quartz crystal microbalance to successfully measure the formation and dissociation of thin films of Xe hydrate formed from ice films in the presence of Xe gas or from a cooled mixture of water vapor and Xe gas. By monitoring the uptake of mass, we have...

  • High-stability quartz-crystal microbalance for investigations in surface science. Bouzidi, L.; Narine, S. S.; Stefanov, K. G.; Slavin, A. J. // Review of Scientific Instruments;Jun2003, Vol. 74 Issue 6, p3039 

    This article describes a high-stability quartz-crystal microbalance (QCM) and the methodology for measuring the change in mass during thin-film growth in deposition and sputter processes. Much lower noise and higher-frequency stability have been achieved than with conventional QCMs. A stability...

  • Effects of humidity on unencapsulated poly(thiophene) thin-film transistors. Chabinyc, Michael L.; Endicott, Fred; Vogt, Bryan D.; DeLongchamp, Dean M.; Lin, Eric K.; Yiliang Wu; Ping Liu; Ong, Beng S. // Applied Physics Letters;3/13/2006, Vol. 88 Issue 11, p113514 

    The effects of humidity on unencapsulated polymeric thin-film transistors (TFTs) of poly[5,5’-bis(3-dodecyl-2-thienyl)-2,2’-bithiophene] (PQT-12) were investigated. The field effect mobility of PQT-12 TFTs decreases and the rate of trapping of charge carriers increases under...

  • Sensitivity study of multilayer thin-film bulk acoustic resonator for mass sensor application. Haiqiang Liu; Fang Li; Lifeng Qin; Qing-Ming Wang // Journal of Applied Physics;10/21/2016, Vol. 120 Issue 15, p1 

    The sensitivity of multilayer thin-film bulk acoustic resonators (MTFBARs) used as mass sensors is investigated. MTFBAR sensors with the structure of a mass-sensitive layer/electrode layer/piezo layer/electrode layer were used. Two methods, one using electric impedance and the other...

  • INTERFACE LAYER TO IMPROVE POLYSTYRENE ATTACHMENT ON A QUARTZ CRYSTAL RESONATOR. Llanes, Doris Susana; Hempel, Ulrike; Ocampo, Aquiles // Revista EIA;dic2005, Issue 4, p9 

    Technologies for thin film deposition have been used to improve the functionalization of quartz crystal resonators (QCR); such technologies, for example, are spin coating and Langmuir-Blodgett (LB) film preparation. These experiments are required because the film uniformity and homogeneity over...

  • Real Time Study of Detergent Concentration Influence on Solid Fatty Acid Film Removal Processes. Favrat, Olivier; Gavoille, Joseph; Aleya, Lotfi; Monteil, Guy // Journal of Surfactants & Detergents;Mar2013, Vol. 16 Issue 2, p213 

    Cleaning in an aqueous solution is a complex mechanism which depends on several parameters. The quartz crystal microbalance (QCM) technique was used to investigate the detachment, using an anionic and a nonionic detergents, of stearic acid (CHO) films deposited on gold-coated quartz surfaces....

  • A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing. Ohlsson, Gabriel; Langhammer, Christoph; Zorić, Igor; Kasemo, Bengt // Review of Scientific Instruments;Aug2009, Vol. 80 Issue 8, p083905 

    A novel device for nanometer-confinement of soft matter in one dimension (1D) is presented. This nanocell, with very large (up to 106:1) cell-radius to cell-height ratio, is tailored as an accessory for quartz crystal microbalance (QCM) and QCM with dissipation-monitoring (QCM-D) sensing to...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.