TITLE

Registration of Alfvén resonances in TCABR tokamak by the scanning reflectometer at sideband frequencies

AUTHOR(S)
Ruchko, L. F.; Elfimov, A. G.; Teixeira, C. M.; Elizondo, J. I.; Sanada, E.; Galvão, R. M. O.; Manso, M. E.; Silva, A.
PUB. DATE
February 2011
SOURCE
Review of Scientific Instruments;Feb2011, Vol. 82 Issue 2, p023504
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A frequency scanning O-mode reflectometer was used for studies of plasma density oscillations during local Alfvén wave (LAW) excitation in the Tokamak Chauffage Alfvén Brésilien (TCABR) at the frequency fA = 5 MHz. It was found that the spectrum of the reflectometer output signal, which consists mainly of the 'beat' frequency fB, is modified by the LAW excitation, and two additional frequency peaks appear, which are symmetrical in relation to the LAW excitation frequency f = fA ± fB. This result opens the possibility to improve the efficiency of studying the LAW induced density oscillations. The symmetry of these frequency peaks yields the possibility of finding the microwave frequency at which the reflectometer cutoff layer coincides with radial position of the LAW resonance zone in the TCABR tokamak.
ACCESSION #
58700477

 

Related Articles

  • Effects of turbulent fluctuations on density measurements with microwave reflectometry in tokamaks. Mazzucato, E.; Nazikian, R. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1237 

    Discusses the effects of turbulent fluctuations on density measurements with microwave reflectometry in tokamaks. Radial fluctuations; Poloidal fluctuations.

  • Development of a fast solid-state high-resolution density profile reflectometer system on the DIII-D tokamak Kim, K. W.; Doyle, E. J.; Rhodes, L.; Peebles, W. A.; Rettig, C. L.; Luhmann, Jr., N. C. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p466 

    Describes the implementation of a highly reliable density profile reflectometer system on the DIII-D tokamak via fast-sweep broadband frequency-modulated reflectometry. Density profile measurements; Signal quality variations with changing frequency sweep rates; Planned improvements to the system.

  • A synthetic diagnostic for the evaluation of new microwave imaging reflectometry diagnostics for DIII-D and KSTAR. Lei, L.; Tobias, B.; Domier, C. W.; Luhmann, N. C.; Kramer, G. J.; Valeo, E. J.; Lee, W.; Yun, G. S.; Park, H. K. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D904 

    The first microwave imaging reflectometry (MIR) system for characterization of fluctuating plasma density has been implemented for the TEXTOR tokamak [H. Park et al., Rev. Sci. Instrum. 75, 3787 (2004)]; an improved MIR system will be installed on DIII-D and KSTAR. The central issue remains in...

  • Microwave reflectometry for turbulence studies on ASDEX upgrade (abstract). Ribeiro, T. T.; Serra, F.; Manso, M. E.; Vergamota, S.; Cupido, L.; Silva, A.; Conway, G. D.; Ryter, F.; Suttrop, W. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p319 

    The reflectometry system installed in the tokamak ASDEX Upgrade has 11 channels primarily aimed at profile measurements and two dedicated channels operating at fixed frequency to study density fluctuations. The channels used for profile measurements can also be operated at fixed frequency. In...

  • Multifrequency channel microwave reflectometer with frequency hopping operation for density fluctuation measurements in Large Helical Device. Tokuzawa, T.; Ejiri, A.; Kawahata, K. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D906 

    In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key...

  • Measurement of plasma density using wavelet analysis of microwave reflectometer signal Bruskin, L.G.; Bruskin, L. G.; Mase, A.; Tokuzawa, T.; Oyama, N.; Itakura, A.; Tamano, T. // Review of Scientific Instruments;Feb1998, Vol. 69 Issue 2, p425 

    Proposes a method of measuring plasma density in the microwave reflectometer signal. Use of wavelet analysis in the method; Achievement of a radial electron density profile; Inclusion of calibration and solution of for integral equation in the electron density reconstruction algorithm.

  • SOL Effects on LH Wave Coupling and Current Drive Performance on Alcator C-Mod. Meneghini, O.; Lau, C.; Shiraiwa, S.; Wallace, G. M.; Parker, R. R.; LaBombard, B. L.; Faust, I. C.; Wilson, J. R.; Wukitch, S. J. // AIP Conference Proceedings;12/23/2011, Vol. 1406 Issue 1, p411 

    On Alcator C-Mod, the LH wave coupling was observed to degrade at higher launched n∥≡ck∥/ω, suggesting that the waves have to tunnel through a millimetric evanescent layer between the plasma and the launcher. Subsequent edge density profile measurements by means of an X-mode...

  • Plasma mass density, species mix, and fluctuation diagnostics using a fast Alfven wave. Ikezi, H; deGrassie, J S; Pinsker, R I; Snider, R T // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p478 

    Proposes the use of a fast Alfven wave interferometer and reflectometer as a tokamak diagnostic to measure the plasma mass density, deuterium-tritium species mix profile, and density fluctuations. Phase velocity of the fast wave propagating across the magnetic field; Position of the ion-ion...

  • Low noise Kα-band hopping reflectometer based on yttrium iron garnet sources at TEXTOR. Soldatov, S.; Krämer-Flecken, A.; Zorenko, O. // Review of Scientific Instruments;Mar2011, Vol. 82 Issue 3, p033513 

    The heterodyne hopping reflectometer system based on wide-tuned low noise yttrium iron garnet sources was developed for TEXTOR experiment. Being installed in 1998 it successfully operates more than 10 years providing the measurements of plasma density fluctuations. Owing to the advance multihorn...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics