TITLE

High-energy x-ray backlighter spectrum measurements using calibrated image plates

AUTHOR(S)
Maddox, B. R.; Park, H. S.; Remington, B. A.; Izumi, N.; Chen, S.; Chen, C.; Kimminau, G.; Ali, Z.; Haugh, M. J.; Ma, Q.
PUB. DATE
February 2011
SOURCE
Review of Scientific Instruments;Feb2011, Vol. 82 Issue 2, p023111
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji™ MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver Kα x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.
ACCESSION #
58700473

 

Related Articles

  • High resolution soft x-ray spectroscopy of low Z K-shell emission from laser-produced plasmas. Dunn, J.; Magee, E. W.; Shepherd, R.; Chen, H.; Hansen, S. B.; Moon, S. J.; Brown, G. V.; Gu, M.-F.; Beiersdorfer, P.; Purvis, M. A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E314 

    A large radius, R=44.3 m, high resolution grating spectrometer (HRGS) with 2400 lines/mm variable line spacing has been designed for laser-produced plasma experiments conducted at the Lawrence Livermore National Laboratory Jupiter Laser Facility. The instrument has been run with a low-noise,...

  • Recording the time dependence of the electron temperature and absolute yield of continuous and line X-rays from flat Au targets irradiated on the Iskra-5 facility. Lazarchuk, V. P.; Muntyan, A. N.; Murugov, V. M.; Petrov, S. I.; Senik, A. V.; Taran, S. S. // Instruments & Experimental Techniques;Mar2008, Vol. 51 Issue 2, p226 

    Two techniques for recording the absolute yield of continuous X rays in the spectral range > 1 keV and M-series line X rays from flat Au targets irradiated with one channel of the Iskra-5 facility are described. In the first and second methods, radiation is detected with a KAP-crystal-based...

  • Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources. Fourment, C.; Arazam, N.; Bonte, C.; Caillaud, T.; Descamps, D.; Dorchies, F.; Harmand, M.; Hulin, S.; Petit, S.; Santos, J. J. // Review of Scientific Instruments;Aug2009, Vol. 80 Issue 8, p083505 

    We present a new operating mode, using a charged coupled device as dispersionless spectrometer dedicated to repetitive x-ray sources in the multi-keV domain. This enables to get spectra with high statistics in a short acquisition time and a way compatible with the operation of other diagnostics...

  • New model ultra-soft X-ray spectrometer for microanalysis. Fukushima, Sei; Kimura, Takashi; Ogiwara, Toshiya; Tsukamoto, Kazunori; Tazawa, Toyohiko; Tanuma, Shigeo // Microchimica Acta;Jun2008, Vol. 161 Issue 3/4, p399 

    The authors developed a new general-purpose analytical apparatus that includes a high-resolution ultra-soft X-ray spectrometer, which notably can be used to efficiently measure the ultra-soft X-ray spectrum over the 30–150 eV range. Over this energy range, the analysis of ultra-light...

  • Recording the energy spectrum and time characteristics of laser-plasma electrons. Bessarab, A. V.; Gorbunov, A. A.; Martsovenko, D. I.; Starodubtsev, V. A.; Sungatullin, R. R. // Instruments & Experimental Techniques;Mar2010, Vol. 53 Issue 2, p258 

    The design of small spectrometers of laser-plasma electrons with energies in the range 1�1000 keV is described. A technique for calibrating spectrometers is presented. The results of measuring an electron spectrum in a laser experiment performed with these spectrometers are presented.

  • Portable, tunable, high-luminosity spherical crystal spectrometer with an x-ray charge coupled device, for high-resolution x-ray spectromicroscopy of clusters heated by femtosecond laser pulses. Blasco, F.; Stenz, C.; Salin, F.; Faenov, A. Ya.; Magunov, A. I.; Pikuz, T. A.; Skobelev, I. Yu. // Review of Scientific Instruments;Apr2001, Vol. 72 Issue 4, p1956 

    A portable (200x100x100 mm[sup 3]), high-luminosity, spherically bent crystal spectrometer was designed for measuring in a wide spectral range of 1.2-19.6 Ã… very low emissivity x-ray spectra of different clusters heated by 35 fs laser radiation. This spectrometer is associated with a custom...

  • Soft x-ray coherent scattering: Instrument and methods at ESRF ID08. Beutier, Guillaume; Marty, Alain; Livet, Frédéric; van der Laan, Gerrit; Stanescu, Stefan; Bencok, Peter // Review of Scientific Instruments;Sep2007, Vol. 78 Issue 9, p093901 

    An experimental setup has been developed to perform soft x-ray coherent scattering at beamline ID08 of the European Synchrotron Radiation Facility. An intense coherent beam was obtained by filtering the primary beam with the monochromator and a circular pinhole. A pinhole holder with motorized...

  • Development of advanced x-ray imaging crystal spectrometer utilizing a large area segmented proportional counter for KSTAR. Lee, S. G.; Bak, J. G.; Nam, U. W.; Moon, M. K.; Cheon, J. K. // Review of Scientific Instruments;Jun2007, Vol. 78 Issue 6, p063504 

    An advanced x-ray imaging crystal spectrometer (XICS) for KSTAR tokamak has been developed by utilizing a segmented two dimensional (2D) position-sensitive multiwire proportional counter. The XICS for the KSTAR tokamak provides time-resolved measurements of the radial ion and electron...

  • The first experimental results from x-ray imaging crystal spectrometer for KSTAR. Lee, S. G.; Bak, J. G.; Nam, U. W.; Moon, M. K.; Shi, Y.; Bitter, M.; Hill, K. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E506 

    The x-ray imaging crystal spectrometer (XICS) for the Korea Superconducting Tokamak Advanced Research has been first applied for the experimental campaign in 2009. The XICS was designed to provide measurements of the profiles of the ion and electron temperatures from the heliumlike argon (Ar...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics