TITLE

Modeling and Analysis of Switching Over voltages Caused by Short Circuits in Ma Cables Connected with Overhead Lines

PUB. DATE
January 2011
SOURCE
Electronics & Electrical Engineering;2011, Issue 107, p107
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
No abstract available.
ACCESSION #
58658739

 

Related Articles

  • Analysis and Mathematical Model for Restitution of Voltage Using Dynamic Voltage Restorer. Gopinath, C.; Yaashuwanth, C.; Ramesh, R.; Maglin, J. R.; Ajith Bosco Raj, T. // Mathematical Problems in Engineering;2014, p1 

    Voltage sag and swell have a major concern in the distribution systems. In order to mitigate the voltage sag and swell, a custom power device called dynamic voltage restorer (DVR) is used. The proposed system is a polymer electrolyte membrane (PEM) fuel cell based DVR. The energy from the fuel...

  • Voltage Sag Compensation in Distribution System Due to SLG Fault Using D-STATCOM. Masdi, Hendri; Mariun, Norman; Bashi, S. M.; Mohamed, Azah // International Review of Electrical Engineering;Nov/Dec2010 Part B, Vol. 5 Issue 6, p2836 

    This paper presents the distribution static compensator (D-STATCOM) for load compensation in an unbalanced distribution system. Simulation were carried out for both cases where, D-STATCOM was connected to the system and not, with simulation interval 0.20 sec. In order to verify the simulation...

  • A Novel Voltage Sag Source Detection Method Using TFR Technique. Faisal, Mohamed F.; Mohamed, Azah; Shareef, Hussain // International Review of Electrical Engineering;Sep/Oct2010 Part B, Vol. 5 Issue 5, p2301 

    Voltage sag is considered as the major power quality disturbance that can disrupt the operation of sensitive equipment. Many power utilities around the world install power quality recorders at strategic sites to monitor the frequency and severity of voltage sags that may affect their customers....

  • A Comprehensive Fault Location Estimation Using Voltage Sag Profile for Non-Homogenous Distribution Networks. Mokhlis, H.; Y. Li, H.; Mohamad, Hasmaini; Bakar, A. H. A. // International Review of Electrical Engineering;Sep/Oct2010 Part B, Vol. 5 Issue 5, p2310 

    An improvement in service continuity of power supply in distribution system could be achieved through a fast fault location. In line with this objective, a fault location method for a distribution network is proposed in this paper. The method uses non-linear voltage sag profile equations as a...

  • Fuzzy Clustering Techniques for the Analysis of PQ Data in Electrical Power Distribution System. Paracha, Zahir J.; Kalam, Akhtar // International Review of Electrical Engineering;Sep/Oct2010 Part B, Vol. 5 Issue 5, p2152 

    No abstract available.

  • Determination of Steady-State and Faulty Regimes of Overhead Lines by Means of Multiconductor Cell Analysis (MCA). Benato, Roberto; Sessa, Sebastian Dambone; Guglielmi, Fabio // Energies (19961073);Aug2012, Vol. 5 Issue 8, p2771 

    Single-phase positive sequence modelling is often used in power systems when power flows and short circuit analysis are assessed. Of course, the use of single-phase positive sequence modelling assumes purely three-phase configurations and perfectly symmetrical ones so that single-phase modelling...

  • Voltage Sag Mitigation in Utility Connected System Using Current Source Converter Based D-STATCOM. Balasubramaniyan, S.; Sivakumaran, T. S.; Rathinambal, S. // International Journal on Electrical & Power Engineering;Aug2013, Vol. 4 Issue 2, p74 

    This paper discusses the implementation of current source converter based distribution type static synchronous compensator. For eliminating the lower order harmonics, the power semiconductors are switched by pulse width modulation technique. Current source converter, input filter, dc link...

  • MODELING OF OVERHEAD TRANSMISSION LINES FOR LIGHTNING OVERVOLTAGE CALCULATIONS. Martínez-Velasco, Juan A.; Castro-Aranda, Ferley // INGENIARE - Revista Chilena de Ingeniería;ene-abr2010, Vol. 18 Issue 1, p120 

    Several parts of an overhead transmission line have to be included in a model adequate for lightning overvoltage studies: wires (shield wires and phase conductors), towers, grounding, insulator strings and air clearances. An additional component, the surge arrester, should be added if the study...

  • Zero-Voltage-Switching Resonant SEPIC Converter. Hyun-Lark Do // International Review of Electrical Engineering;Sep/Oct2011 Part A, Vol. 6 Issue 5, p2106 

    A zero-voltage-switching (ZVS) resonant single-ended primary inductor converter (SEPIC) is presented in this paper. The voltage multiplier technique and active clamp technique are applied to the conventional SEPIC converter to increase the voltage gain, reduce the voltage stresses of the power...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics