TITLE

Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008

AUTHOR(S)
Catuzzo, P.; Aimonetto, S.; Zenone, F.; Fanelli, G.; Marchisio, P.; Meloni, T.; Pasquino, M.; Tofani, S.
PUB. DATE
December 2010
SOURCE
British Journal of Radiology;Dec2010, Vol. 83 Issue 996, p1042
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Recent and continuous advances in CT, such as the development of multislice CT, have promoted a rapid increase in its clinical application. Today, CT accounts for approximately 10% of the total number of medical radiographic procedures worldwide. However, the growing performance of the new CT generations have increased not only the diagnostic opportunities, but also the radiation dose to the patient. The relative contribution to the collective radiation dose is now estimated to be approximately 50%. Several papers have been published concerning the intensive use of CT and its contribution to the collective dose. However, most of the literature concerns the years 1997-2003 and the dosimetric evaluations are generally limited to the main standard protocols (chest, head and abdomen), deriving the effective dose by the simple application of the diagnostic reference levels. Only specific dosimetric analyses of single and innovative procedures have been published recently. Moreover, few data comes from Italian radiology departments. This paper aims to bridge these gaps. Firstly, it characterises in terms of measured CT dose index (CTDI) two last-generation scanners of the Radiological Department of Aosta Hospital. Secondly, it evaluates the effective dose from most of the CT examinations performed from 2001 to 2008 to compare protocols and technologies in line with the suggestions of the 2007 Recommendations of the International Commission on Radiological Protection, Publication 103. Finally, it estimates the collective dose to the population.
ACCESSION #
57934375

 

Related Articles

  • Clinical evaluation of a breathing protocol for PET/CT. de Juan, Ramon; Seifert, Burkhardt; Berthold, Thomas; von Schulthess, Gustav K.; Goerres, Gerhard W. // European Radiology;Jun2004, Vol. 14 Issue 6, p1118 

    The aim of this study was to assess the frequency and severity of respiration-induced curvilinear respiration artifacts (RICA) on co-registered positron emission tomography/computed tomography (PET/CT) images acquired on a combined PET/CT scanner before and after modifying the respiration...

  • MONTE CARLO CALCULATION OF RADIATION DOSE IN CT EXAMINATIONS USING PHANTOM AND PATIENT TOMOGRAPHIC MODELS. Salvadó, M.; López, M.; Morant, J. J.; Calzado, A. // Radiation Protection Dosimetry;2005, Vol. 114 Issue 1-3, p364 

    By using a voxel-based Monte Carlo simulation technique, we developed and validated a method to calculate radiation-absorbed dose in the computed tomography (CT) examinations from the images of phantoms and patients. The ionising radiation transport was simulated using the EGS4 code system. The...

  • Dosimetry in Medical Exposures: Trends, Challenges and Next Steps. Schauer, David A. // AIP Conference Proceedings;5/5/2011, Vol. 1345 Issue 1, p181 

    According to a recently released report from the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) medical exposures account for 98% of the contribution from manmade sources of ionizing radiation and are now the second largest contributor to population dose...

  • Patient doses of CT examinations in Western and Eastern Azerbyjan provinces of Iran. Firouzi, Fariba; Minaei, Soraya Emamgholizadeh; Khosravi, Hamid Reza // Journal of Paramedical Sciences;Autumn2014, Vol. 5 Issue 4, p15 

    Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of computed tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiation...

  • Current status of medical radiation exposure and regulation efforts. Whal Lee // Journal of the Korean Medical Association / Taehan Uisa Hyophoe ;Dec2011, Vol. 54 Issue 12, p1248 

    The radiation exposure from diagnostic medical imaging has increased. The potential risk from radiation exposure of the patient also has increased even though the risk from a small amount of radiation exposure has not been clearly demonstrated. Any medical radiation exposure must be justified...

  • Pediatric CT quality management and improvement program. Larson, David; Molvin, Lior; Wang, Jia; Chan, Frandics; Newman, Beverley; Fleischmann, Dominik // Pediatric Radiology;Oct2014 Supplement, Vol. 44, p519 

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality...

  • MGH customizes CT radiation doses using virtual autopsy.  // Medicine on the Net;Jul2011, Vol. 17 Issue 7, p6 

    The article reports on the testing and customization of computed tomography (CT) protocols on cadavers at Massachusetts General Hospital in Boston, Massachusetts to determine the dosage needed among live patients in as much as half of the national reference levels.

  • ASSESSMENT OF PATIENT ORGAN DOSES AND EFFECTIVE DOSES USING THE VIP-MAN ADULT MALE PHANTOM FOR SELECTED CONE-BEAM CT IMAGING PROCEDURES DURING IMAGE GUIDED RADIATION THERAPY. Jianwei Gu; Bednarz, Bryan; X. George Xu; Jiang, Steve B. // Radiation Protection Dosimetry;2008, Vol. 131 Issue 4, p431 

    A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A...

  • CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality. Zhang, Wei-lan; Li, Min; Zhang, Bo; Geng, Hai-yang; Liang, Yin-qiang; Xu, Ke; Li, Song-bai // PLoS ONE;Dec2013, Vol. 8 Issue 12, p1 

    Objectives: We aimed to assess the effectiveness and feasibility of head-and-neck Computed Tomography Angiography (CTA) with low tube voltage and low concentration contrast media combined with iterative reconstruction algorithm. Methods: 92 patients were randomly divided into group A and B:...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.