TITLE

Combined quantitative ultrasonic and time-resolved interaction force AFM imaging

AUTHOR(S)
Parlak, Z.; Degertekin, F. L.
PUB. DATE
January 2011
SOURCE
Review of Scientific Instruments;Jan2011, Vol. 82 Issue 1, p013703
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The authors describe a method where quantitative ultrasonic atomic force microscopy (UAFM) is achieved during time-resolved interaction force (TRIF) imaging in intermittent contact mode. The method uses a calibration procedure for quantitative UAFM. It improves elasticity measurements of stiff regions of surfaces while retaining the capabilities of the TRIF mode for topography, adhesion, dissipation, and elasticity measurements on soft regions of sample surfaces. This combination is especially advantageous when measuring and imaging samples with broad stiffness range in a nondestructive manner. The experiments utilize an active AFM probe with high bandwidth and the UAFM calibration is performed by measuring the magnitude of the time-resolved UAFM signal at a judiciously chosen frequency for different contact stiffness values during individual taps. Improved sensitivity to stiff surface elasticity is demonstrated on a special sample. The results show that combining UAFM with TRIF provides 2.5 GPa (5%) standard deviation on the silicon surface reduced Young's modulus, representing 5× improvement over using only TRIF mode imaging.
ACCESSION #
57679738

 

Related Articles

  • Energy dissipation in tapping-mode atomic force microscopy. Cleveland, J. P.; Anczykowski, B.; Schmid, A. E.; Elings, V. B. // Applied Physics Letters;5/18/1998, Vol. 72 Issue 20 

    A method is presented to measure the energy dissipated by the tip–sample interaction in tapping-mode atomic force microscopy (AFM). The results show that if the amplitude of the cantilever is held constant, the sine of the phase angle of the driven vibration is then proportional to...

  • Real time reduction of probe-loss using switching gain controller for high speed atomic force microscopy. Agarwal, Pranav; De, Tathagata; Salapaka, Murti V. // Review of Scientific Instruments;Oct2009, Vol. 80 Issue 10, p103701 

    In this article, a switching gain proportional-integral-differential controller is used to reduce probe-loss affected regions in an image, obtained during tapping mode operation. Switching signal is derived from the “reliability index” signal, which demarcates regions where the tip...

  • Energy dissipation during nanoscale indentation of polymers with an atomic force microscope. Boschung, E.; Heuberger, M. // Applied Physics Letters;6/27/1994, Vol. 64 Issue 26, p3566 

    Analyzes the energy dissipation during nanoscale indentation of polymers with an atomic force microscope. Application of the nanoscale indentation in electronic or micromechanical devices; Nanomechanical properties of polymer; Mechanism of indentation.

  • Stability of an oscillating tip in noncontact atomic force microscopy: Theoretical and numerical investigations. Couturier, G.; Nony, L.; Boisgard, R.; Aime´, J.-P. // Journal of Applied Physics;2/15/2002, Vol. 91 Issue 4, p2537 

    This article is a theoretical and a numerical investigation of the stability of a tip–cantilever system used in noncontact atomic force microscopy (NC-AFM) when it oscillates close to a surface. No additional dissipative force is considered. The theoretical approach is based on a...

  • Polystyrene latex particles as a size calibration for the atomic force microscope. Li, Y.; Lindsay, S. M. // Review of Scientific Instruments;Nov91, Vol. 62 Issue 11, p2630 

    A simple method for spreading polystyrene-latex spheres onto mica substrates to form highly crystalline layers is described. These layers can be used as a simple calibration standard for the atomic force microscope in the nanometer to micron size range. In particular, they provide simultaneous...

  • z calibration of the atomic force microscope by means of a pyramidal tip. Jensen, F. // Review of Scientific Instruments;Sep93, Vol. 64 Issue 9, p2595 

    A new method for imaging the probe tip of an atomic force microscope cantilever by the atomic force microscope itself (self-imaging) is presented. The self-imaging is accomplished by scanning the probe tip across a sharper tip on the surface. By using a pyramidal probe tip with a very...

  • Imaging of single polymer chains based on their elasticity. Akari, S.O.; van der Vegte, E.W. // Applied Physics Letters;10/10/1994, Vol. 65 Issue 15, p1915 

    Examines the elasticity of individual polystyrene molecules. Use of force modulation technique with standard atomic force microscope; Direction of vibration for samples mounted on a piezoelectric tube; Basis for surface topography function.

  • Localized sureface elasticity measurements using an atomic force microscope. DeVecchio, Derik; Bhushan, Bharat // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4498 

    Investigates localized surface elasticity measurements using an atomic force microscope. Identification and mapping of the differences in the stiffness of elasticity of ultrathin films; Provision of an alternative to current elasticity measurements; Application of the technique to...

  • Modified atomic force microscope applied to the measurement of elastic modulus for a single peptide molecule. Ptak, Arkadiusz; Takeda, Seiji; Nakamura, Chikashi; Miyake, Jun; Kageshima, Masami; Jarvis, Suzanne P.; Tokumoto, Hiroshi // Journal of Applied Physics;9/15/2001, Vol. 90 Issue 6 

    A modified atomic force microscopy (AFM) system, based on a force modulation technique, has been used to find an approximate value for the elastic modulus of a single peptide molecule directly from a mechanical test. For this purpose a self-assembled monolayer built from two kinds of peptides,...