Over almost 50 years of its development, the science of immunology has become an indispensable tool for the understanding of the histology of tissues. Antibodies are highly specific probes, so that tissue structure can be interpreted not just by morphological considerations but by association with a wide variety of physiological molecular antigens. The simple concept of an antibody linked to a microscopically dense marker remains constant in each application of the technique, such as the use of fluorescent markers or the incorporation of electron-dense gold colloids for electron microscopy. We describe a new application of immunocytochemistry to x-ray spectromicroscopy: the antibody labeling of tissue structures with nickel precipitates. Regions of positive staining can be seen by the acquisition of nickel distribution maps in the MEPHISTO X-PEEM from the intense Ni L-edge absorption features around 850 eV. The aim of this work is to know the background tissue structures on which the distribution of other relevant elements (such as boron for BNCT) can be mapped. Results are presented showing positive staining by two antibodies in human glioblastoma tissue, anti-Ki-67, a protein found in the nuclei of proliferating cells, and anti-van Witlebrandt factor, located in blood vessel endothelia. We show that the criteria for successful staining for optical microscopy are different than for spectroscopic imaging, but useful results can be obtained with careful image treatment.
ACCESSION #
5664436

 

Related Articles

  • Malignant Mesothelioma and Occupational Exposure to Asbestos: An Analysis of 1445 Cases. Butnor, K. J.; Sharma, A.; Sporn, T. A.; Roggli, V. L. // Annals of Occupational Hygiene;2002, Vol. 46 Issue suppl_1, p150 

    Asbestos exposure is indisputably associated with the development of malignant mesothelioma (MM). However, relatively few studies have correlated the manner of exposure with asbestos fiber content and type. We report findings from 1445 MMs with known exposure histories, including fiber burden...

  • Microanalysis by monochromatic microprobe x-ray fluorescence -physical basis, properties, ... Chen, Z.W.; Wittry, D.B. // Journal of Applied Physics;7/15/1998, Vol. 84 Issue 2, p1064 

    Presents an microanalysis on the physical basis, properties of monochromatic microprobe x-ray fluorescene (MMXRF). Discussion on the experimental parameters of MMXRF; Characterization of the mica diffractor; Description of the diffraction and properties of the mica diffractor and the...

  • The X-ray source populations of the magellanic clouds. Haberl, F. // AIP Conference Proceedings;2001, Vol. 599 Issue 1, p449 

    ROSAT performed about 250 PSPC observations pointed towards the Magellanic Clouds (MCs). A systematic analysis of the data yielded catalogues with more than 750 X-ray sources in the LMC and about 520 in the SMC region. Cross-correlations with catalogues from various other wavelength bands and...

  • X-rays with the Midas touch. Franklin, Carl // New Scientist;7/17/93, Vol. 139 Issue 1882, p21 

    Reports on KX Technology's Goldstream analyser which can accurately detect gold in a ton of ore. Measurement of solid and dissolved gold; On-stream analyser; X-ray fluorescence spectrometry.

  • Microchannel-plate intensified crystal spectrometer for use in soft x-ray spectroscopy. Hailey, C. J.; Rockett, P.; Eckart, M.; Burkhalter, P. G. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1553 

    A Bragg crystal spectrometer, utilizing a microchannel plate coupled to optical film as the detection medium, has been constructed for use in soft x-ray spectroscopy. The sensitivity of this intensified gated camera to x-rays has been compared directly with standard x-ray film using a calibrated...

  • Two-channel, elliptical analyzer spectrograph for absolute, time-resolving time-integrating spectrometry of pulsed x-ray sources in the 100–10 000-eV region. Henke, B. L.; Jaanimagi, P. A. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1537 

    A new spectrographic system has been developed and calibrated in this laboratory for the absolute spectrometry of high-intensity pulsed x-ray sources in the 100–10 000-eV region. This spectral region is analyzed with fixed elliptically curved crystals and molecular or...

  • X-ray fluorescence analysis of lead in bone Landrigan, Philip J.; Todd, Andrew C. // Environmental Health Perspectives;Nov1993, Vol. 101 Issue 6, p494 

    No abstract available.

  • 2D imaging by X-ray fluorescence microtomography. Simionovici, A.; Chukalina, M.; Drakopoulos, M.; Snigireva, I.; Snigirev, A.; Schroer, Ch.; Lengeler, B.; Janssens, K.; Adams, F. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p539 

    First experimental results of fluorescence microtomography in “pencil-beam” geometry with 6 μm resolution obtained at the ESRF/ID 22 are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method...

  • Erratum: Triple-Crystal X-ray Spectroscopy of Diffuse Scattering from Tracks [Crystallogr.Rep. Vol. 46, No. 5, 2001, pp. 717�721]. Peregudov, V. N.; Pashaev, �. M. // Crystallography Reports;Jul2002, Vol. 47 Issue 4, p705 

    Presents a correct reprint of an article about triple-crystal X-ray spectroscopy of diffuse scattering from tracks.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics