TITLE

Reorganization of clusters in cluster-cluster-aggregation

AUTHOR(S)
Vormoor, O.; Thieme, J.
PUB. DATE
May 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 507 Issue 1, p250
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
X-ray microscopy and scattering experiments give different experimental results when determining the fractal dimension of colloidal clusters. A two dimensional simulation model is presented to describe reorganization of clusters during the aggregation process. Considering this reorganization gives a rapidly increasing fractal dimension from d=1.53 to d=1.61. This result implies that the fractal dimension of the clusters is mainly affected by reorganization of small sub clusters.
ACCESSION #
5664425

 

Related Articles

  • Visualizing membrane turnover in trypanosomes. Stead, A. D.; Ford, T. W.; Page, A. M.; Majima, T.; Shimizu, H.; Tomie, T. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p163 

    After incubation with colloidal gold, x-ray dense particles accumulated within (or on the surface of) the cells of the trypanosome Crithidia fasciculata. These particles appeared to accumulate at the posterior of the cell and it is only when cells were imaged rapidly and after maintenance at...

  • Hard X-ray Fluorescence Microscopy to Determine the Element Distribution of Soil Colloids in Aqueous Environment. Gleber, S.-C.; Vogt, S.; Niemeyer, J.; Finney, L.; McNulty, I.; Thieme, J. // AIP Conference Proceedings;9/9/2011, Vol. 1365 Issue 1, p365 

    A prominent feature of soil colloids is their huge specific surface. It determines colloidal properties such as adsorption capacity or diffusion. The colloidal interactions differ significantly from the behavior of the same materials in a bulk system. Interactions in the colloidal regime are...

  • Development of Coherent X-ray Diffraction Apparatus with Kirkpatrick-Baez Mirror Optics. Takahashi, Y.; Tsutsumi, R.; Nishino, Y.; Mimura, H.; Matsuyama, S.; Ishikawa, T.; Yamauchi, K. // AIP Conference Proceedings;9/9/2011, Vol. 1365 Issue 1, p231 

    To realize coherent x-ray diffraction microscopy with higher spatial resolution, it is necessary to increase the density of x-ray photons illuminated onto the sample. In this study, we developed a coherent x-ray diffraction apparatus with Kirkpatrick-Baez mirror optics. By using mirrors...

  • X-ray imaging microscopy using a micro capillary X-ray refractive lens. Kohmura, Yoshiki; Okada, Kyoko; Awaji, Mitsuhiro; Suzuki, Yoshio; Ishikawa, Tetsuya; Dudchik, Yu. I.; Kolchevsky, N. N.; Komarov, F. F. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p566 

    A first X-ray imaging microscopy test using the two types of “micro-capillary lens” (kind of the X-ray refractive lenses) has been done at the undulator and bending magnet radiation of SPring-8. One (lens No.1) contained bubbles in glue whereas the other (lens No.2) contained bubbles...

  • State of art micro-CT. Sassov, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p515 

    By using high technology an X-ray microtomograph (micro-CT) was created as a simply usable, desktop instrument. The micro-CT is a laboratory system for non-destructive three-dimensional microscopy, giving true spatial resolution over a million times more detailed than the medical CT-scanners.

  • X-ray speckle correlation interferometer. Eisenhower, Rachel; Materlik, Gerhard // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p488 

    Speckle Pattern Correlation Interferometry (SPCI) is a well-established technique in the visible-light regime for observing surface disturbances. Although not a direct imaging technique, SPCI gives full-field, high-resolution information about an object's motion. Since x-ray synchrotron...

  • High-resolution X-ray imaging and tomography at the ESRF beamline ID 22. Weitkamp, T.; Drakopoulos, M.; Leitenberger, W.; Raven, C.; Schroer, C.; Simionovici, A.; Snigireva, I.; Snigirev, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p424 

    At the ESRF micro-fluorescence, imaging and diffraction (μ-FID) beamline ID 22, a microimaging and tomography setup has been operational for several months. The coherence properties of the high-energy X-ray undulator beam at ID 22 make the setup especially suited for phase-contrast tomography...

  • Imaging magnetic structures with a transmission X-ray microscope. Fischer, P.; Eimu¨ller, T.; Schu¨tz, G.; Guttmann, P.; Schmahl, G.; Bayreuther, G. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p205 

    The X-ray magnetic circular dichroism (X-MCD), i.e. the dependence of the absorption of circularly polarized X-rays on the magnetization of the absorber exhibits at Ledges of transition metals values up to 25%. This can serve as a huge magnetic contrast mechanism in combination with a...

  • BIOLOGICAL PHYSICS. Feder, Ralph // Physics Today;Jan86, Vol. 39 Issue 1, pS-12 

    Focuses on the applications of contact x-ray microscopy in the United States. Use of x-ray sources and high magnification of an electron microscope; Procedure on contact x-ray microscopy; Availability of synchrotron as source for soft x rays.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics