TITLE

Composition mapping considerations in scanning soft x-ray microscopy

AUTHOR(S)
Buckley, C. J.
PUB. DATE
May 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 507 Issue 1, p33
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The effects of distortion to absorption measurements made in the soft x-ray region are considered in this paper. The effects of background radiation, spectral contamination, resolving power and detector non-linearity is discussed within the context of what is required for quantitative compositional mapping.
ACCESSION #
5664408

 

Related Articles

  • The measuring and mapping of calcium in mineralized tissues by absorption difference imaging. Buckley, C.J. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1318 

    Presents a review of the mapping of calcium in mineralized tissues by absorption difference imaging using scanning x-ray microscopy at the calcium L edge. Principles of mapping and measuring concentration; Mapping of concentration via pre- and post-edge energies; Description of the L-shell...

  • X-ray imaging microscopy using a micro capillary X-ray refractive lens. Kohmura, Yoshiki; Okada, Kyoko; Awaji, Mitsuhiro; Suzuki, Yoshio; Ishikawa, Tetsuya; Dudchik, Yu. I.; Kolchevsky, N. N.; Komarov, F. F. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p566 

    A first X-ray imaging microscopy test using the two types of “micro-capillary lens” (kind of the X-ray refractive lenses) has been done at the undulator and bending magnet radiation of SPring-8. One (lens No.1) contained bubbles in glue whereas the other (lens No.2) contained bubbles...

  • State of art micro-CT. Sassov, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p515 

    By using high technology an X-ray microtomograph (micro-CT) was created as a simply usable, desktop instrument. The micro-CT is a laboratory system for non-destructive three-dimensional microscopy, giving true spatial resolution over a million times more detailed than the medical CT-scanners.

  • X-ray speckle correlation interferometer. Eisenhower, Rachel; Materlik, Gerhard // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p488 

    Speckle Pattern Correlation Interferometry (SPCI) is a well-established technique in the visible-light regime for observing surface disturbances. Although not a direct imaging technique, SPCI gives full-field, high-resolution information about an object's motion. Since x-ray synchrotron...

  • High-resolution X-ray imaging and tomography at the ESRF beamline ID 22. Weitkamp, T.; Drakopoulos, M.; Leitenberger, W.; Raven, C.; Schroer, C.; Simionovici, A.; Snigireva, I.; Snigirev, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p424 

    At the ESRF micro-fluorescence, imaging and diffraction (μ-FID) beamline ID 22, a microimaging and tomography setup has been operational for several months. The coherence properties of the high-energy X-ray undulator beam at ID 22 make the setup especially suited for phase-contrast tomography...

  • Reorganization of clusters in cluster-cluster-aggregation. Vormoor, O.; Thieme, J. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p250 

    X-ray microscopy and scattering experiments give different experimental results when determining the fractal dimension of colloidal clusters. A two dimensional simulation model is presented to describe reorganization of clusters during the aggregation process. Considering this reorganization...

  • Imaging magnetic structures with a transmission X-ray microscope. Fischer, P.; Eimu¨ller, T.; Schu¨tz, G.; Guttmann, P.; Schmahl, G.; Bayreuther, G. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p205 

    The X-ray magnetic circular dichroism (X-MCD), i.e. the dependence of the absorption of circularly polarized X-rays on the magnetization of the absorber exhibits at Ledges of transition metals values up to 25%. This can serve as a huge magnetic contrast mechanism in combination with a...

  • BIOLOGICAL PHYSICS. Feder, Ralph // Physics Today;Jan86, Vol. 39 Issue 1, pS-12 

    Focuses on the applications of contact x-ray microscopy in the United States. Use of x-ray sources and high magnification of an electron microscope; Procedure on contact x-ray microscopy; Availability of synchrotron as source for soft x rays.

  • Single-movement fixed-exit channelcut x-ray monochromator based on profiled surfaces. Oestreich, Sebastian; Kaulich, Burkhard; Susini, Jean // Review of Scientific Instruments;Apr99, Vol. 70 Issue 4, p1921 

    Describes the development of a fixed-exit channelcut monochromator, which requires only a single rotational movement. Construction of the surface profile; Influence of thermal load on the monochromator; Transmission; Spectral resolution; Stability of the beam position.