TITLE

Demonstration of phase contrast in scanning transmission X-ray microscopy: Comparison of images obtained at NSLS X1-A with numerical simulations

AUTHOR(S)
Polack, Franc¸ois; Joyeux, Denis; Feser, Michael; Phalippou, Daniel; Carlucci-Dayton, Mary; Kaznacheyev, Konstantyn; Jacobsen, Chris
PUB. DATE
May 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 507 Issue 1, p573
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Unlike transmission X-ray microscopy, scanning transmission X-ray microscopy (STXM), till now, does not allow phase contrast. Several method have been suggested but no proof of practical feasibility has been yet given. Here we analyze the methods based on the detection of the small beam deflection induced by the object phase gradient, by a segmented detector. It is shown that structuring the zone plate illumination potentially improves the detection. A diffractive beam profiler has been constructed to condition the beam of the NSLS X1A STXM. Recent images are shown, which, compared to numerical simulations, indicate the presence of phase contrast.
ACCESSION #
5664355

 

Related Articles

  • X-ray imaging microscopy using a micro capillary X-ray refractive lens. Kohmura, Yoshiki; Okada, Kyoko; Awaji, Mitsuhiro; Suzuki, Yoshio; Ishikawa, Tetsuya; Dudchik, Yu. I.; Kolchevsky, N. N.; Komarov, F. F. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p566 

    A first X-ray imaging microscopy test using the two types of “micro-capillary lens” (kind of the X-ray refractive lenses) has been done at the undulator and bending magnet radiation of SPring-8. One (lens No.1) contained bubbles in glue whereas the other (lens No.2) contained bubbles...

  • State of art micro-CT. Sassov, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p515 

    By using high technology an X-ray microtomograph (micro-CT) was created as a simply usable, desktop instrument. The micro-CT is a laboratory system for non-destructive three-dimensional microscopy, giving true spatial resolution over a million times more detailed than the medical CT-scanners.

  • X-ray speckle correlation interferometer. Eisenhower, Rachel; Materlik, Gerhard // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p488 

    Speckle Pattern Correlation Interferometry (SPCI) is a well-established technique in the visible-light regime for observing surface disturbances. Although not a direct imaging technique, SPCI gives full-field, high-resolution information about an object's motion. Since x-ray synchrotron...

  • High-resolution X-ray imaging and tomography at the ESRF beamline ID 22. Weitkamp, T.; Drakopoulos, M.; Leitenberger, W.; Raven, C.; Schroer, C.; Simionovici, A.; Snigireva, I.; Snigirev, A. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p424 

    At the ESRF micro-fluorescence, imaging and diffraction (μ-FID) beamline ID 22, a microimaging and tomography setup has been operational for several months. The coherence properties of the high-energy X-ray undulator beam at ID 22 make the setup especially suited for phase-contrast tomography...

  • Reorganization of clusters in cluster-cluster-aggregation. Vormoor, O.; Thieme, J. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p250 

    X-ray microscopy and scattering experiments give different experimental results when determining the fractal dimension of colloidal clusters. A two dimensional simulation model is presented to describe reorganization of clusters during the aggregation process. Considering this reorganization...

  • Imaging magnetic structures with a transmission X-ray microscope. Fischer, P.; Eimu¨ller, T.; Schu¨tz, G.; Guttmann, P.; Schmahl, G.; Bayreuther, G. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p205 

    The X-ray magnetic circular dichroism (X-MCD), i.e. the dependence of the absorption of circularly polarized X-rays on the magnetization of the absorber exhibits at Ledges of transition metals values up to 25%. This can serve as a huge magnetic contrast mechanism in combination with a...

  • BIOLOGICAL PHYSICS. Feder, Ralph // Physics Today;Jan86, Vol. 39 Issue 1, pS-12 

    Focuses on the applications of contact x-ray microscopy in the United States. Use of x-ray sources and high magnification of an electron microscope; Procedure on contact x-ray microscopy; Availability of synchrotron as source for soft x rays.

  • Single-movement fixed-exit channelcut x-ray monochromator based on profiled surfaces. Oestreich, Sebastian; Kaulich, Burkhard; Susini, Jean // Review of Scientific Instruments;Apr99, Vol. 70 Issue 4, p1921 

    Describes the development of a fixed-exit channelcut monochromator, which requires only a single rotational movement. Construction of the surface profile; Influence of thermal load on the monochromator; Transmission; Spectral resolution; Stability of the beam position.

  • Soft X-Ray Microscopy and EUV Lithography: An Update on Imaging at 20–40 nm Spatial Resolution. Attwood, D.; Anderson, E.; Denbeaux, G.; Goldberg, K.; Naulleau, P.; Schneider, G. // AIP Conference Proceedings;2002, Vol. 641 Issue 1, p461 

    Major advances in both soft x-ray microscopy, at wavelengths from 0.6 to 4 nm, and EUV lithography, at wavelengths between 13 and 14 nm, are reviewed. In the XRL-2000 proceedings[SUP1] we reported soft x-ray microscopy resolved to 25 nm, in static two-dimensional imaging, with applications to...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics