TITLE

Design of X-ray interferometer for phase-contrast X-ray microtomography

AUTHOR(S)
Momose, Atsushi; Hirano, Keiichi
PUB. DATE
May 2000
SOURCE
AIP Conference Proceedings;2000, Vol. 507 Issue 1, p98
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We tested an X-ray interferometer fabricated to improve the spatial resolution of phase-contrast X-ray computed tomography (CT). The main factor limiting the spatial resolution is the diffraction phenomenon in the crystal wafer of the interferometer. Improvement of the spatial resolution was attempted by thinning the wafer. A preliminary test was performed by checking interference patterns. Thinning the wafer from 1 to 0.24 mm showed clear improvement in the image quality.
ACCESSION #
5664319

 

Related Articles

  • X-ray microtomography (μCT) using interferometric phase contrast. Bonse, Ulrich; Beckmann, Felix; Biermann, Theodor // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p69 

    Phase-contrast tomography is capable of characterizing organic tissues, e.g. rat trigenimal nerve or brain matter by accurate measurement of mass density P[sub m]. The presently attained accuracy is of the order of 10[sup −3] relative. Aspects of importance for reaching this accuracy are...

  • Development of Apparatus for Phase Imaging Using X-Ray Interferometers at BL20XU of SPring-8. Momose, A.; Koyama, I.; Hamaishi, Y.; Kawamoto, S.; Takai, K.; Uesugi, K.; Suzuki, Y.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1259 

    Phase-contrast X-ray imaging, including phase tomography, was performed at the medium-length beamline BL20XU of SPring-8, where undulator X rays were available at 245 m from the source point. A crystal X-ray interferometer and an X-ray Talbot interferometer with transmission gratings were used...

  • X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source. Herzen, Julia; Donath, Tilman; Beckmann, Felix; Ogurreck, Malte; David, Christian; Mohr, Jürgen; Pfeiffer, Franz; Schreyer, Andreas // Review of Scientific Instruments;Nov2011, Vol. 82 Issue 11, p113711 

    X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron...

  • Three-Dimensional Observation of Polymer Blends with X-ray Phase Tomography. Higuchi, N.; Momose, A.; Yashiro, W.; Takeda, Y.; Jinnai, H.; Nishikawa, Y.; Suzuki, Y. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p1369 

    We performed a quantitative three-dimensional observation of polystyrene (PS)/poly(methyl methacrylate) (PMMA) blends by X-ray phase tomography mainly using the crystal X-ray interferometer at the beamline 20XU of SPring-8, Japan. We observed the time change in the phase-separated structures of...

  • Detection of sub-pixel fractures in X-ray dark-field tomography. Lauridsen, Torsten; Willner, Marian; Bech, Martin; Pfeiffer, Franz; Feidenhans'l, Robert // Applied Physics A: Materials Science & Processing;Nov2015, Vol. 121 Issue 3, p1243 

    We present a new method for detecting fractures in solid materials below the resolution given by the detector pixel size by using grating-based X-ray interferometry. The technique is particularly useful for detecting sub-pixel cracks in large samples where the size of the sample is preventing...

  • Quantized positioning of x-ray interferometers. Bergamin, A.; Cavagnero, G.; Mana, G. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p17 

    Demonstrates the feasibility of quantized positioning and moving scanning x-ray interferometers by feedback of traveling fringes. Mechanical model of the interferometer; Quantized positioning; Frog-jump movement.

  • Shearing x-ray interferometer with an x-ray prism. Kohmura, Yoshiki; Ishikawa, Tetsuya; Takano, Hidekazu; Suzuki, Yoshio // Journal of Applied Physics;2/15/2003, Vol. 93 Issue 4, p2283 

    A wave front dividing interferometer was devised in which half of a highly spatially coherent beam deflected by an x-ray prism is overlapped with another half. By placing the samples in the two beams and the x-ray imaging detector closely downstream of the sample, the differential phase of the...

  • Application-Oriented X-ray Grating Interferometer. Revol, V.; Kottler, C.; Kaufmann, R.; Jerjen, I.; Lüthi, T.; Cardot, F.; Niedermann, Ph.; Sennhauser, U.; Straumann, U.; Urban, C. // AIP Conference Proceedings;4/15/2010, Vol. 1236 Issue 1, p221 

    Grating-based Differential Phase Contrast X-ray imaging (DPCi) provides, in one measurement, unique information about the absorption coefficient, the index of refraction and the microscopic structure of a sample at hard X-ray frequencies11-17. For this reason, DPCi can potentially overcome the...

  • Phase Contrast Cone Beam Tomography with an X-Ray Grating Interferometer. Jerjen, I.; Revol, V.; Kottler, C.; Luethi, Th.; Sennhauser, U.; Kaufmann, R.; Urban, C. // AIP Conference Proceedings;4/15/2010, Vol. 1236 Issue 1, p227 

    We report on our recent developments of reconstruction algorithms for Differential Phase Contrast X-ray Computed Tomography (DPC CT). DPC images provide information about the real and imaginary part of the refractive index which is an advantage when objects with poor absorption but good phase...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics